ECM hydrogel coating mitigates the chronic inflammatory response to polypropylene mesh

被引:141
作者
Faulk, Denver M. [1 ,2 ]
Londono, Ricardo [2 ,3 ]
Wolf, Matthew T. [1 ,2 ]
Ranallo, Christian A. [1 ,2 ]
Carruthers, Christopher A. [1 ,2 ]
Wildemann, Justin D. [1 ,2 ]
Dearth, Christopher L. [2 ,4 ]
Badylak, Stephen F. [1 ,2 ,4 ]
机构
[1] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15219 USA
[2] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15219 USA
[3] Univ Pittsburgh, Sch Med, Pittsburgh, PA 15219 USA
[4] Univ Pittsburgh, Dept Surg, Pittsburgh, PA 15219 USA
基金
美国国家科学基金会;
关键词
ECM (extracellular matrix); Hydrogel; Surgical mesh; Polypropylene; Coated surgical mesh; Foreign body response; EXTRACELLULAR-MATRIX; DEGRADATION-PRODUCTS; MECHANICAL-PROPERTIES; HERNIA REPAIR; SCAFFOLD; RECONSTRUCTION; IMPLANTATION; COLLAGEN; TISSUE;
D O I
10.1016/j.biomaterials.2014.06.057
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polypropylene has been used as a surgical mesh material for several decades. This non-degradable synthetic polymer provides mechanical strength, a predictable host response, and its use has resulted in reduced recurrence rates for ventral hernia and pelvic organ prolapse. However, polypropylene and similar synthetic materials are associated with a chronic local tissue inflammatory response and dense fibrous tissue deposition. These outcomes have prompted variations in mesh design to minimize the surface area interface and increase integration with host tissue. In contrast, biologic scaffold materials composed of extracellular matrix (ECM) are rapidly degraded in-vivo and are associated with constructive tissue remodeling and minimal fibrosis. The objective of the present study was to assess the effects of an ECM hydrogel coating on the long-term host tissue response to polypropylene mesh in a rodent model of abdominal muscle injury. At 14 days post implantation, the ECM coated polypropylene mesh devices showed a decreased inflammatory response as characterized by the number and distribution of M1 macrophages (CD86+/CD68+) around mesh fibers when compared to the uncoated mesh devices. At 180 days the ECM coated polypropylene showed decreased density of collagen and amount of mature type I collagen deposited between mesh fibers when compared to the uncoated mesh devices. This study confirms and extends previous findings that an ECM coating mitigates the chronic inflammatory response and associated scar tissue deposition characteristic of polypropylene. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8585 / 8595
页数:11
相关论文
共 45 条
[1]   Differences in polypropylene shrinkage depending on mesh position in an experimental study [J].
Angel Garcia-Urena, Miguel ;
Vega Ruiz, Vicente ;
Diaz Godoy, Antonio ;
Baez Perea, Jose Maria ;
Marin Gomez, Luis Miguel ;
Carnero Hernandez, Francisco Javier ;
Velasco Garcia, Miguel Angel .
AMERICAN JOURNAL OF SURGERY, 2007, 193 (04) :538-542
[2]   Resorbable bioscaffold for esophageal repair in a dog model [J].
Badylak, S ;
Meurling, S ;
Chen, M ;
Spievack, A ;
Simmons-Byrd, A .
JOURNAL OF PEDIATRIC SURGERY, 2000, 35 (07) :1097-1103
[3]   Esophageal reconstruction with ECM and muscle tissue in a dog model [J].
Badylak, SF ;
Vorp, DA ;
Spievack, AR ;
Simmons-Byrd, A ;
Hanke, J ;
Freytes, DO ;
Thapa, A ;
Gilbert, TW ;
Nieponice, A .
JOURNAL OF SURGICAL RESEARCH, 2005, 128 (01) :87-97
[4]   The extracellular matrix as a biologic scaffold material [J].
Badylak, Stephen F. .
BIOMATERIALS, 2007, 28 (25) :3587-3593
[5]   Extracellular matrix as a biological scaffold material: Structure and function [J].
Badylak, Stephen F. ;
Freytes, Donald O. ;
Gilbert, Thomas W. .
ACTA BIOMATERIALIA, 2009, 5 (01) :1-13
[6]   Tissue-engineered skin: Current status in wound healing [J].
Bello Y.M. ;
Falabella A.F. ;
Eaglstein W.H. .
American Journal of Clinical Dermatology, 2001, 2 (5) :305-313
[7]   Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp - Part I: Experimental results [J].
Billiar, KL ;
Sacks, MS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (01) :23-30
[8]   Antibacterial activity within degradation products of biological scaffolds composed of extracellular matrix [J].
Brennan, Ellen P. ;
Reing, Janet ;
Chew, Douglas ;
Myers-Irvin, Julie M. ;
Young, E. J. ;
Badylak, Stephen F. .
TISSUE ENGINEERING, 2006, 12 (10) :2949-2955
[9]   Chemoattractant activity of degradation products of fetal and adult skin extracellular matrix for keratinocyte progenitor cells [J].
Brennan, Ellen P. ;
Tang, Xiao-Han ;
Stewart-Akers, Ann M. ;
Gudas, Lorraine J. ;
Badylak, Stephen F. .
JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2008, 2 (08) :491-498
[10]   Macrophage phenotype as a predictor of constructive remodeling following the implantation of biologically derived surgical mesh materials [J].
Brown, Bryan N. ;
Londono, Ricardo ;
Tottey, Stephen ;
Zhang, Li ;
Kukla, Kathryn A. ;
Wolf, Matthew T. ;
Daly, Kerry A. ;
Reing, Janet E. ;
Badylak, Stephen F. .
ACTA BIOMATERIALIA, 2012, 8 (03) :978-987