Efficient parameter estimation for anatomy deformation models used in 4D-CT

被引:0
作者
Zachariah, Elizabeth S. [1 ]
Fei, Ding-Yu [2 ]
Docef, Alen [1 ]
机构
[1] Virginia Commonwealth Univ, Elect & Comp Engn, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Biomed Engn, Richmond, VA 23284 USA
来源
20TH INTERNATIONAL CONFERENCE ON CIRCUITS, SYSTEMS, COMMUNICATIONS AND COMPUTERS (CSCC 2016) | 2016年 / 76卷
关键词
COMPUTED-TOMOGRAPHY; MOTION ESTIMATION; IMAGE;
D O I
10.1051/matecconf/20167602003
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
A critical feature of radiation therapy for cancerous tumors located in the thorax and abdomen is addressing tumor motion due to breathing. To achieve this goal, a CT study (ordinarily denoted as 4D-CT) showing tumor location, size, and shape against time is essential. Several 4D-CT reconstruction methods have been proposed that employ anatomy deformation models. The proposed method estimates temporal parameters for these models using an approach that does not require markers or manual designation of landmark anatomical features. A neural network is trained to estimate the parameters based on simple statistical features of the CT projections. The proposed method achieves an average estimation error of less than 0.02 seconds, corresponding to a spatial error of less than 1.3 mm. The accuracy of the proposed method is evaluated in the presence of several limiting constraints such as computational complexity and noise.
引用
收藏
页数:6
相关论文
共 26 条
[1]   The future of IGRT -: Cost benefit analysis [J].
Baumann, Michael ;
Hoelscher, Tobias ;
Zips, Daniel .
ACTA ONCOLOGICA, 2008, 47 (07) :1188-1192
[2]  
Ben-Israel A., 2003, Generalized inverses: theory and applications, V15
[3]   4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis [J].
Boldea, Vlad ;
Sharp, Gregory C. ;
Jiang, Steve B. ;
Sarrut, David .
MEDICAL PHYSICS, 2008, 35 (03) :1008-1018
[4]   Reconstruction of a cone-beam CT image via forward iterative projection matching [J].
Brock, R. Scott ;
Docef, Alen ;
Murphy, Martin J. .
MEDICAL PHYSICS, 2010, 37 (12) :6212-6220
[5]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[6]   Advances in image-guided radiation therapy [J].
Dawson, Laura A. ;
Jaffray, David A. .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (08) :938-946
[7]   Image-guided radiotherapy: rationale, benefits, and limitations [J].
Dawson, Laura A. ;
Sharpe, Michael B. .
LANCET ONCOLOGY, 2006, 7 (10) :848-858
[8]   Reconstruction of 4D deformed CT for moving anatomy [J].
Docef, Alen ;
Murphy, Martin J. .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 3 (06) :591-598
[9]   4-dimensional computed tomography imaging and treatment planning [J].
Keall, P .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :81-90
[10]   Acquiring 4D thoracic CT scans using a multislice helical method [J].
Keall, PJ ;
Starkschall, G ;
Shukla, H ;
Forster, KM ;
Ortiz, V ;
Stevens, CW ;
Vedam, SS ;
George, R ;
Guerrero, T ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :2053-2067