Voxel dosimetry: Comparison of MCNPX and DOSXYZnrc Monte Carlo codes in patient specific phantom calculations

被引:3
作者
Hadad, Kamal [1 ]
Saeedi-Moghadam, Mahdi [2 ]
Zeinali-Rafsanjani, Banafsheh [2 ,3 ]
机构
[1] Shiraz Univ, Sch Mech Engn, Dept Nucl Engn, Shiraz, Iran
[2] Shiraz Univ Med Sci, Med Imaging Res Ctr, Shiraz, Iran
[3] Shiraz Univ Med Sci, Nucl Med & Mol Imaging Res Ctr, Shiraz, Iran
关键词
MCNPX; EGSnrc; voxel phantom; patient specific phantom; DOSXYZnrc; DVH; HYBRID COMPUTATIONAL PHANTOMS; CANCER-RISK ESTIMATION; RADIATION-THERAPY; DOSE CALCULATION; HUMAN ANATOMY; VALIDATION; EGS4; ELECTRON; MODELS; TOOL;
D O I
10.3233/THC-161240
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
INTRODUCTION: Dose evaluation with two Monte Carlo codes using patient specific voxel phantom is presented in this paper. We employ both MCNPX and DOSXYZnrc to perform dosimetry for mathematical voxel phantoms generated by our in-house developed voxel phantom generator and EGSnrc/CTCreate respectively. MATERIAL AND METHOD: Our case study was a 2.5 x 2.4 x 2.4 cm(3) tumor in the middle lobe of right lung of a male patient exposed to 6MV parallel beam. In order to compare these Monte Carlo codes with together gross tumor volume (GTV) and organ at risks (OAR) doses and dose volume histograms (DVH) were calculated. RESULTS: Comparing the mean absorbed dose results (in Gy) from both codes indicates that gross tumor volume, heart and spinal cord have 2% to 10% difference. The 10% difference between the codes were from the spinal cord region where was not in the therapy beam and it just received the scatter radiation. The dose volume DVH obtained from DOSXYZnrc results demonstrate a milder slope compared with MCNPX DVHs. CONCLUSION: It was revealed that MCNPX has some advantages in comparison to DOSXYZnrc, but it is important to consider that for equal precision in voxel dosimetry calculation, DOSXYZnrc runs faster than MCNPX and it is a great advantage.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [41] Preclinical voxel-based dosimetry through GATE Monte Carlo simulation using PET/CT imaging of mice
    Gupta, Arun
    Lee, Min Sun
    Kim, Joong Hyun
    Park, Sohyeon
    Park, Hyun Soo
    Kim, Sang Eun
    Lee, Dong Soo
    Lee, Jae Sung
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (09)
  • [42] Evaluation of the Monte Carlo method (KTMAN-2) in fluoroscopic dosimetry and comparison with experiment
    Kim, Minho
    Lee, Hyounggun
    Kim, Hyosim
    Park, Hongmin
    Lee, Wonho
    Park, Sungho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (06) : 936 - 940
  • [43] Evaluation of the Monte Carlo method (KTMAN-2) in fluoroscopic dosimetry and comparison with experiment
    Minho Kim
    Hyounggun Lee
    Hyosim Kim
    Hongmin Park
    Wonho Lee
    Sungho Park
    Journal of the Korean Physical Society, 2014, 64 : 936 - 940
  • [44] Comparison Comparison of parameters affecting GNP-loaded choroidal melanoma dosimetry; Monte Carlo study
    Sharabiani, Marjan
    Asadi, Somayeh
    Barghi, Amir Rahnamai
    Vaezzadeh, Mehdi
    RADIATION PHYSICS AND CHEMISTRY, 2018, 145 : 180 - 183
  • [45] Review and comparison of effective delayed neutron fraction calculation methods with Monte Carlo codes
    Becares, V.
    Perez-Martin, S.
    Vazquez-Antolin, M.
    Villamarin, D.
    Martin-Fuertes, F.
    Gonzalez-Romero, E. M.
    Merino, I.
    ANNALS OF NUCLEAR ENERGY, 2014, 65 : 402 - 410
  • [46] Dosimetry of MammoSite® applicator: Comparison between Monte Carlo simulation, measurements, and treatment planning calculation
    Oshaghi, Mina
    Sadeghi, Mahdi
    Mahdavi, Seied Rabi
    Shirazi, Alireza
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2013, 9 (02) : 224 - 229
  • [47] Comparison of Monte Carlo with pencil beam dosimetry for lung CyberKnife SBRT, correlation with local recurrence
    Ove, Roger
    Parker, Colbert A.
    Chilukuri, Madhu B.
    Russo, Suzanne M.
    JOURNAL OF RADIATION ONCOLOGY, 2015, 4 (03) : 257 - 263
  • [48] Evaluating the Application of Tissue-Specific Dose Kernels Instead of Water Dose Kernels in Internal Dosimetry: A Monte Carlo Study
    Moghadam, Maryam Khazaee
    Asl, Alireza Kamali
    Geramifar, Parham
    Zaidi, Habib
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2016, 31 (10) : 367 - 379
  • [49] Dual-energy contrast-enhanced digital mammography: Glandular dose estimation using a Monte Carlo code and voxel phantom
    Tzamicha, E.
    Yakoumakis, E.
    Tsalafoutas, I. A.
    Dimitriadis, A.
    Georgiou, E.
    Tsapaki, V.
    Chalazonitis, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 785 - 791
  • [50] VALIDATION OF MONTE CARLO DOSE CALCULATION FOR PAEDIATRIC CT EXAMINATIONS USING TUBE CURRENT MODULATION BASED ON IN-PHANTOM DOSIMETRY
    Fujii, K.
    Nomura, K.
    Muramatsu, Y.
    Obara, S.
    Goto, T.
    Akahane, K.
    Ota, H.
    Tsukagoshi, S.
    Kusumoto, M.
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) : 508 - 517