Voxel dosimetry: Comparison of MCNPX and DOSXYZnrc Monte Carlo codes in patient specific phantom calculations

被引:3
作者
Hadad, Kamal [1 ]
Saeedi-Moghadam, Mahdi [2 ]
Zeinali-Rafsanjani, Banafsheh [2 ,3 ]
机构
[1] Shiraz Univ, Sch Mech Engn, Dept Nucl Engn, Shiraz, Iran
[2] Shiraz Univ Med Sci, Med Imaging Res Ctr, Shiraz, Iran
[3] Shiraz Univ Med Sci, Nucl Med & Mol Imaging Res Ctr, Shiraz, Iran
关键词
MCNPX; EGSnrc; voxel phantom; patient specific phantom; DOSXYZnrc; DVH; HYBRID COMPUTATIONAL PHANTOMS; CANCER-RISK ESTIMATION; RADIATION-THERAPY; DOSE CALCULATION; HUMAN ANATOMY; VALIDATION; EGS4; ELECTRON; MODELS; TOOL;
D O I
10.3233/THC-161240
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
INTRODUCTION: Dose evaluation with two Monte Carlo codes using patient specific voxel phantom is presented in this paper. We employ both MCNPX and DOSXYZnrc to perform dosimetry for mathematical voxel phantoms generated by our in-house developed voxel phantom generator and EGSnrc/CTCreate respectively. MATERIAL AND METHOD: Our case study was a 2.5 x 2.4 x 2.4 cm(3) tumor in the middle lobe of right lung of a male patient exposed to 6MV parallel beam. In order to compare these Monte Carlo codes with together gross tumor volume (GTV) and organ at risks (OAR) doses and dose volume histograms (DVH) were calculated. RESULTS: Comparing the mean absorbed dose results (in Gy) from both codes indicates that gross tumor volume, heart and spinal cord have 2% to 10% difference. The 10% difference between the codes were from the spinal cord region where was not in the therapy beam and it just received the scatter radiation. The dose volume DVH obtained from DOSXYZnrc results demonstrate a milder slope compared with MCNPX DVHs. CONCLUSION: It was revealed that MCNPX has some advantages in comparison to DOSXYZnrc, but it is important to consider that for equal precision in voxel dosimetry calculation, DOSXYZnrc runs faster than MCNPX and it is a great advantage.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [31] Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code
    Martins, M. C.
    Cordeiro, T. P. V.
    Silva, A. X.
    Souza-Santos, D.
    Queiroz-Filho, P. P.
    Hunt, J. G.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 309 - 312
  • [32] A Voxel-Dose Algorithm of Heterogeneous Activity Distribution for Monte-Carlo Simulation of Radionuclide Therapy Dosimetry
    Lin, Hui
    Jing, Jia
    Cai, Jinfeng
    Xu, Liangfeng
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2012, 27 (06) : 344 - 352
  • [33] Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry
    Araki, Fujio
    Hanyu, Yuji
    Fukuoka, Miyoko
    Matsumoto, Kenji
    Okumura, Masahiko
    Oguchi, Hiroshi
    MEDICAL PHYSICS, 2009, 36 (07) : 2992 - 3001
  • [34] DOSIS: An An integrated computational tool for patient-specific dosimetry in nuclear medicine by Monte Carlo and dose point kernel approaches
    Perez, Pedro
    Valente, Mauro
    APPLIED RADIATION AND ISOTOPES, 2019, 150 : 135 - 140
  • [35] Digital phantom versus patient-specific radiation dosimetry in adult routine thorax CT examinations
    Papadakis, Antonios E.
    Giannakaki, Vassiliki
    Stratakis, John
    Myronakis, Marios
    Zaidi, Habib
    Damilakis, John
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (07):
  • [36] Calculation of S-values for Technetium-99m in the DIGIMOUSE voxel phantom using Monte Carlo simulations
    Teles, P.
    Antunes, J.
    Gomez-Ros, J. M.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 196
  • [37] Voxel2MCNP: a framework for modeling, simulation and evaluation of radiation transport scenarios for Monte Carlo codes
    Poelz, Stefan
    Laubersheimer, Sven
    Eberhardt, Jakob S.
    Harrendorf, Marco A.
    Keck, Thomas
    Benzler, Andreas
    Breustedt, Bastian
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16) : 5381 - 5400
  • [38] Mouse S-factors based on monte carlo simulations in the anatomical realistic Moby phantom for internal dosimetry
    Larsson, Erik
    Strand, Sven-Erik
    Ljungberg, Michael
    Jonsson, Bo-Anders
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2007, 22 (03) : 438 - 442
  • [39] Monte Carlo simulation and patient dosimetry for a kilovoltage cone-beam CT unit
    Downes, P.
    Jarvis, R.
    Radu, E.
    Kawrakow, I.
    Spezi, E.
    MEDICAL PHYSICS, 2009, 36 (09) : 4156 - 4167
  • [40] EVALUATION OF ORGAN DOSES IN ADULT AND PAEDIATRIC CT EXAMINATIONS BASED ON MONTE CARLO SIMULATIONS AND IN-PHANTOM DOSIMETRY
    Fujii, K.
    Nomura, K.
    Muramatsu, Y.
    Takahashi, K.
    Obara, S.
    Akahane, K.
    Satake, M.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 166 - 171