摘要
PURPOSE: To evaluate three different percutaneous portosystemic shunts created with magnetic resonance (MR) imaging and fluoroscopy guidance in a swine model. MATERIALS AND METHODS: In stage 1 of the experiment, an active MR intravascular needle system was created for needle tracking and extracaval punctures. Twenty inferior vena cava (IVC)/superior mesenteric vein (SMV)/portal vein (PV) punctures were performed in 10 swine (weight, 40-45 kg) in a 1.5-T short-bore interventional MR imager. With use of a real-time MR imaging sequence, the needle was guided through the IVC and into the SMV or PV (N = 20 punctures). After confirmation, a wire was advanced into the portal venous system under MR imaging guidance (N = 20). In stage 2, animals were transferred to the radiographic fluoroscopy suite for deployment of shunts. Three different shunts were evaluated in this study: (i) a commercial stent-graft, GO a prototype bridging stent, and (iii) a prototype nitinol vascular anastomotic device. Postprocedural necropsy was performed in all animals. RESULTS: Successful MR-guided IVC/SMV punctures were performed in all 20 procedures (100%). All three shunts were deployed. Stent-grafts had the poorest mechanism for securing a shunt. The vascular anastomotic device and the bridging stent had more secure anchoring mechanisms but also had higher technical failure rates (50% and 40%, respectively). When deployed successfully, the vascular anastornotic device resulted in no bleeding at the sites of punctures at necropsy. CONCLUSION: Percutaneous shunts and vascular artastomoses between the portal mesenteric venous system and IVC were successfully created with use of a combination of MR imaging and conventional fluoroscopy for guidance.
引用
收藏
页码:1165 / 1173
页数:9
相关论文
共 20 条
[1]   Magnetic resonance image-guided trans-septal puncture in a swine heart [J].
Arepally, A ;
Karmarkar, PV ;
Weiss, C ;
Rodriguez, ER ;
Lederman, RJ ;
Atalar, E .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :463-467
[2]   Catheter-tracking FOV MR fluoroscopy [J].
Atalar, E ;
Kraitchman, DL ;
Carkhuff, B ;
Lesho, J ;
Ocali, O ;
Solaiyappan, M ;
Guttman, MA ;
Charles, HK .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :865-872
[3]  
Henderson J M, 1997, Liver Transpl Surg, V3, P552, DOI 10.1002/lt.500030514
[4]  
Henderson J M, 1993, Adv Surg, V26, P233
[5]   SELECTIVE SHUNT IN THE MANAGEMENT OF VARICEAL BLEEDING IN THE ERA OF LIVER-TRANSPLANTATION [J].
HENDERSON, JM ;
GILMORE, GT ;
HOOKS, MA ;
GALLOWAY, JR ;
DODSON, TF ;
HOOD, MM ;
KUTNER, MH ;
BOYER, TD ;
RIKKERS, LF ;
BUSUTTIL, RW .
ANNALS OF SURGERY, 1992, 216 (03) :248-255
[6]   ROLE OF DISTAL SPLENORENAL SHUNT FOR LONG-TERM MANAGEMENT OF VARICEAL BLEEDING [J].
HENDERSON, JM .
WORLD JOURNAL OF SURGERY, 1994, 18 (02) :205-210
[7]   Surgical shunts and tips for variceal decompression in the 1990s [J].
Henderson, JM ;
Nagle, A ;
Curtas, S ;
Geisinger, M ;
Barnes, D .
SURGERY, 2000, 128 (04) :540-546
[8]   50 YEARS OF SURGERY FOR PORTAL-HYPERTENSION AT THE CLEVELAND-CLINIC-FOUNDATION - LESSONS AND PROSPECTS [J].
HERMANN, RE ;
HENDERSON, JM ;
VOGT, DP ;
MAYES, JT ;
GEISINGER, MA ;
AGNOR, C .
ANNALS OF SURGERY, 1995, 221 (05) :459-468
[9]   Biliary-venous fistula complicating transjugular intrahepatic portosystemic shunt presenting with recurrent bacteremia, jaundice, anemia and fever [J].
Jawaid, Q ;
Saeed, ZA ;
Di Bisceglie, AM ;
Brunt, EM ;
Ramrakhiani, S ;
Varma, CR ;
Solomon, H .
AMERICAN JOURNAL OF TRANSPLANTATION, 2003, 3 (12) :1604-1607
[10]   Percutaneous retroperitoneal splenorenal shunt:: An experimental study in swine [J].
Kaminou, T ;
Rösch, J ;
Yamada, R ;
Uchida, BT ;
Pavcnik, D ;
Timmermans, HA ;
Sakaguchi, S ;
Keller, FS .
RADIOLOGY, 1998, 206 (03) :799-802