Suitability of Different Observational Lenses for Viewing the Macular Area Through Multifocal Intraocular Lenses in a Model of the Human Eye

被引:3
作者
Watanabe, Tomoyuki [1 ]
Watanabe, Akira [1 ]
Nakano, Tadashi [1 ]
机构
[1] Jikei Univ, Dept Ophthalmol, Sch Med, Tokyo 1058461, Japan
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
multifocal intraocular lenses; vitrectomy; macula; SURGERY; IMAGE; VISUALIZATION; VITRECTOMY; QUALITY; SYSTEM;
D O I
10.2147/OPTH.S272341
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Multifocal intraocular lenses (IOLs) can potentially affect the intraoperative view of the retina. We investigated the suitability of different lenses for viewing the macular area through two multifocal intraocular lenses in a human eye model. Methods: This study compared the image quality of graduated index (0.1 mm) in a model eye when viewed through refractive or diffractive multifocal IOLs with a meniscus or flat contact lens, and a wide field 60 diopter non-contact lens or wide field contact lens (Super Macula (R)). Results: Images acquired through the meniscus contact lens or flat contact lens via the central optical zone of the refractive multifocal IOL or the diffractive multifocal IOL were well focused. However, images viewed through these lenses near the center were warped and out of focus. All images viewed through a wide-field 60 diopter non-contact lens at the central optical zone and near the center were slightly out of focus. All images viewed through the Super Macula at the central optical zone and near the center were well focused. Conclusion: A wide field contact lens (Super Macula (R)) made it possible to obtain clear images of the macular area at multiple focal points through refractive or diffractive multifocal IOLs.
引用
收藏
页码:3279 / 3284
页数:6
相关论文
共 16 条
[1]   Multifocal intraocular lenses: An overview [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Fernandez-Buenaga, Roberto ;
Pikkel, Joseph ;
Maldonado, Miguel .
SURVEY OF OPHTHALMOLOGY, 2017, 62 (05) :611-634
[2]   Optics of wide-angle panoramic viewing system-assisted vitreous surgery [J].
Chalam, KV ;
Shah, VA .
SURVEY OF OPHTHALMOLOGY, 2004, 49 (04) :437-445
[3]  
de Oliveira Paulo Ricardo Chaves, 2016, Int J Retina Vitreous, V2, P28
[4]  
Ho P C, 1983, Ophthalmology, VSuppl, P106
[5]  
Inoue M, 2012, DEV OPHTHALMOL, V54, P87
[6]   Quality of image of grating target placed in vitreous of isolated pig eyes photographed through different implanted multifocal intraocular lenses [J].
Inoue, Makoto ;
Noda, Toru ;
Ohnuma, Kazuhiko ;
Bissen-Miyajima, Hiroko ;
Hirakata, Akito .
ACTA OPHTHALMOLOGICA, 2011, 89 (07) :E561-E566
[7]   Quality of Image of Grating Target Placed in Model of Human Eye With Corneal Aberrations as Observed Through Multifocal Intraocular Lenses [J].
Inoue, Makoto ;
Noda, Toru ;
Mihashi, Toshifumi ;
Ohnuma, Kazuhiko ;
Bissen-Miyajima, Hiroko ;
Hirakata, Akito .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (04) :644-652
[8]   Multifocal Intraocular Lens Explantation: A Case Series of 50 Eyes [J].
Kamiya, Kazutaka ;
Hayashi, Ken ;
Shimizu, Kimiya ;
Negishi, Kazuno ;
Sato, Masaki ;
Bissen-Miyajima, Hiroko .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (02) :215-220
[9]   Intraoperative findings during vitreous surgery after implantation of diffractive multifocal intraocular lens [J].
Kawamura, Ryosuke ;
Inoue, Makoto ;
Shinoda, Kei ;
Bissen-Miyajima, Hiroko .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06) :1048-1049
[10]  
Kumar A, 1996, ACTA OPHTHALMOL SCAN, V74, P415