Changes in Early Serum Metal Ion Levels and Impact on Liver, Kidney, and Immune Markers Following Metal-on-Metal Total Hip Arthroplasty

被引:11
作者
Chen, Zhefeng [1 ]
Wang, Zhen [1 ]
Wang, Qing [1 ]
Cui, Weiding [1 ]
Liu, Feng [1 ]
Fan, Weimin [1 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Dept Orthoped, Nanjing 210029, Jiangsu, Peoples R China
关键词
metal-on-metal; metal-on-polyethylene; metal ion; immunity; hip arthroplasty; DIAMETER TOTAL HIP; LONG-TERM; JOHN CHARNLEY; REPLACEMENT; CHROMIUM; COBALT; RELEASE; WEAR; BEARINGS; IMPLANTS;
D O I
10.1016/j.arth.2013.07.031
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We retrospectively studied 32 consecutive patients (32 hips) who underwent THA with a Durom large-head, MOM articulation between January 2008 and December 2010. Of the patients who underwent THA using a Trilogy metal on polyethylene prosthesis during the same period, 32 were chosen to form the Trilogy group. 32 volunteers were chosen to form the control group. At the last follow-up, serum metal ion levels, liver and kidney function and host immunologic immune responses were evaluated. The mean Co and Cr levels in the Durom group were 4.33- and 1.95-fold higher than those in the Trilogy group. CD3 +, CD4 + and CD8 + cell levels in the Durom group were significantly decreased. The INF-gamma level in the Durom group was significantly higher than that in the Trilogy and control groups. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:612 / 616
页数:5
相关论文
共 35 条
[1]   A Prospective Metal Ion Study of Large-Head Metal-on-Metal Bearing: A Matched-Pair Analysis of Hip Resurfacing Versus Total Hip Replacement [J].
Beaule, Paul E. ;
Kim, Paul R. ;
Hamdi, Amre ;
Fazekas, Anna .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (02) :251-+
[2]   Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Grübl, A ;
Jankovsky, R ;
Meisinger, V ;
Lehr, S ;
Gottsauner-Wolf, F .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :66-70
[3]   Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes - An in vitro study [J].
Burroughs, BR ;
Hallstrom, B ;
Golladay, GJ ;
Hoeffel, D ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :11-19
[4]  
Campbell P, 2004, CLIN ORTHOP RELAT R, P98
[5]   Nine-Year Incidence of Kidney Disease in Patients Who Have Had Total Hip Arthroplasty [J].
Chandran, Shaun E. ;
Giori, Nicholas J. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (06) :24-27
[6]   The clinical significance of metal ion release from cobalt-chromium metal-on-metal hip joint arthroplasty [J].
Cobb, AG ;
Schmalzreid, TP .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :385-398
[7]   An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements [J].
Davies, AP ;
Willert, HG ;
Campbell, PA ;
Learmonth, ID ;
Case, CP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) :18-27
[8]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[9]   Long-term outcome of a cementless, hemispherical, press-fit acetabular component SURVIVORSHIP ANALYSIS AND DOSE-RESPONSE RELATIONSHIP TO LINEAR POLYETHYLENE WEAR [J].
Emms, N. W. ;
Stockley, I. ;
Hamer, A. J. ;
Wilkinson, J. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (06) :856-861
[10]   2008 John Charnley Award: Metal Ion Levels After Metal-on-Metal Total Hip Arthroplasty: A Randomized Trial [J].
Engh, C. Anderson, Jr. ;
MacDonald, Steven J. ;
Sritulanondha, Supatra ;
Thompson, Abigail ;
Naudie, Douglas ;
Engh, Charles A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) :101-111