Fluorescence spectroscopy of anisole at elevated temperatures and pressures
被引:20
作者:
Tran, K. H.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Paris 06, CNRS, UMR 7190, Inst Jean Le Rond dAlembert, F-78210 St Cyr Lecole, FranceUniv Paris 06, CNRS, UMR 7190, Inst Jean Le Rond dAlembert, F-78210 St Cyr Lecole, France
Tran, K. H.
[1
]
Morin, C.
论文数: 0引用数: 0
h-index: 0
机构:
UVHC, TEMPO, F-59313 Valenciennes 9, FranceUniv Paris 06, CNRS, UMR 7190, Inst Jean Le Rond dAlembert, F-78210 St Cyr Lecole, France
Morin, C.
[2
]
Kuehni, M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Lyon, INSA Lyon, CNRS, UMR 5008,CETHIL, F-69621 Villeurbanne, FranceUniv Paris 06, CNRS, UMR 7190, Inst Jean Le Rond dAlembert, F-78210 St Cyr Lecole, France
Kuehni, M.
[3
]
Guibert, P.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Paris 06, CNRS, UMR 7190, Inst Jean Le Rond dAlembert, F-78210 St Cyr Lecole, FranceUniv Paris 06, CNRS, UMR 7190, Inst Jean Le Rond dAlembert, F-78210 St Cyr Lecole, France
Guibert, P.
[1
]
机构:
[1] Univ Paris 06, CNRS, UMR 7190, Inst Jean Le Rond dAlembert, F-78210 St Cyr Lecole, France
[2] UVHC, TEMPO, F-59313 Valenciennes 9, France
[3] Univ Lyon, INSA Lyon, CNRS, UMR 5008,CETHIL, F-69621 Villeurbanne, France
Laser-induced fluorescence of anisole as tracer of isooctane at an excitation wavelength of 266 nm was investigated for conditions relevant to rapid compression machine studies and for more general application of internal combustion engines regarding temperature, pressure, and ambient gas composition. An optically accessible high pressure and high temperature chamber was operated by using different ambient gases (Ar, N-2, CO2, air, and gas mixtures). Fluorescence experiments were investigated at a large range of pressure and temperature (0.2-4 MPa and 473-823 K). Anisole fluorescence quantum yield decreases strongly with temperature for every considered ambient gas, due to efficient radiative mechanisms of intersystem crossing. Concerning the pressure effect, the fluorescence signal decreases with increasing pressure, because increasing the collisional rate leads to more important non-radiative collisional relaxation. The quenching effect is strongly efficient in oxygen, with a fluorescence evolution described by Stern-Volmer relation. The dependence of anisole fluorescence versus thermodynamic parameters suggests the use of this tracer for temperature imaging in specific conditions detailed in this paper. The calibration procedure for temperature measurements is established for the single-excitation wavelength and two-color detection technique.