High Definition Laparoscopy: Objective Assessment of Performance Characteristics and Comparison with Standard Laparoscopy

被引:30
作者
Pierre, Sean A. [1 ]
Ferrandino, Michael N. [1 ]
Simmons, W. Neal [2 ]
Fernandez, Christina [2 ]
Zhong, Pei [2 ]
Albala, David M. [1 ]
Preminger, Glenn M. [1 ]
机构
[1] Duke Univ, Med Ctr, Comprehens Kidney Stone Ctr, Durham, NC 27710 USA
[2] Duke Univ, Therapeut Res Lab, Pratt Sch Engn, Durham, NC USA
关键词
MINIMALLY INVASIVE SURGERY; DISTORTION CORRECTION; TASK-PERFORMANCE; HAPTIC FEEDBACK; VIDEO; SYSTEMS; IMAGES; REGISTRATION; NEPHRECTOMY; TECHNOLOGY;
D O I
10.1089/end.2008.0277
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: High definition (HD) digital imaging represents a major advance in endoscope technology. The development of the charge-coupled device chip and its location at the distal end of the endoscope allows for image capture and digitization, as well as specific light filtration and processing. We assessed the capability of HD technology combined with digital imaging to provide improved image quality and enhanced spatial three-dimensional positioning. Methods: A HD digital laparoscope and a standard definition (SD) laparoscope were evaluated in the laboratory setting to assess and compare image resolution, brightness, contrast, and color reproducibility, using standard industry testing protocols. Results: Compared with the SD laparoscope, the HD laparoscope had superior resolution at 50mm distance (2.4 line pairs/mm v 2.0 line pairs/mm), increased image brightness (129 lumens v 112 lumens), increased depth of field, and decreased distortion. Color and grayscale reproduction were found to be similar for the two laparoscopes. Conclusion: HD laparoscopy has superior objective performance characteristics compared with standard laparoscopes. Further investigation is required to determine whether these objective findings translate into subjective improvements, and which characteristics can be adjusted to obtain the best possible results. These improved optics may lead to easier identification of anatomic structures, finer dissection, and enhanced three-dimensional spatial positioning during HD laparoscopic procedures.
引用
收藏
页码:523 / 528
页数:6
相关论文
共 30 条
  • [1] A new approach for nonlinear distortion correction in endoscopic images based on least squares estimation
    Asari, KV
    Kumar, S
    Radhakrishnan, D
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (04) : 345 - 354
  • [2] Technique of distortion correction in endoscopic images using a polynomial expansion
    Asari, KV
    Kumar, S
    Radhakrishnan, D
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (01) : 8 - 12
  • [3] Advances in digital imaging during endoscopic surgery
    Aslan, P
    Kuo, RL
    Hazel, K
    Babayan, RK
    Preminger, GM
    [J]. JOURNAL OF ENDOUROLOGY, 1999, 13 (04) : 251 - 255
  • [4] Understanding and optimizing laparoscopic videosystems
    Berber, E
    Siperstein, AE
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (08): : 781 - 787
  • [5] BERCI G, 1995, SURG ENDOSC-ULTRAS, V9, P967
  • [6] Bholat OS, 1999, ST HEAL T, V62, P62
  • [7] A novel approach to high definition, high-contrast video capture in abdominal surgery
    Cosman, Peter H.
    Shearer, Christopher J.
    Hugh, Thomas J.
    Biankin, Andrew V.
    Merrett, Neil D.
    [J]. ANNALS OF SURGERY, 2007, 245 (04) : 533 - 535
  • [8] The effect of contrast variation on task performance in video evaluation
    Danis, J
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1998, 12 (08): : 1013 - 1016
  • [9] FLORES A, 2004, J ASS MEX SURG ENDOS, V5, P104
  • [10] Critical comparison of laparoscopic, robotic, and open radical prostatectomy: Techniques, outcomes, and cost
    Gettman M.T.
    Blute M.L.