Facile and Sensitive Method for Detecting Cardiac Markers using Ubiquitous pH Meters

被引:42
作者
Kwon, Donghoon [1 ]
Joo, Jinmyoung [1 ]
Lee, Sanghee [1 ]
Jeon, Sangmin [1 ]
机构
[1] Pohang Univ Sci & Technol, POSTECH, Dept Chem Engn, Pohang 790794, South Korea
关键词
TROPONIN-I;
D O I
10.1021/ac403329w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and easy method was developed for the detection of the cardiac marker troponin I using magnetic immunoassay and ubiquitous pH meters. Monoclonal antibody-functionalized Fe3O4 magnetic nanoparticle clusters (MNCs) were synthesized to capture troponin in human serum, and MNC-troponin complexes were magnetically isolated using a permanent magnet. These complexes were subsequently conjugated to polyclonal antibody-functionalized acetylcholinesterase (AchE) and dispersed in acetylcholine (Ach) solution. As the Ach was hydrolyzed to choline and acetic acid, the pH of the solution decreased, and the resulting pH change was measured in real time using a pH meter. The sensitivity of detection of this assay was found to be 10 pg/mL of troponin in human serum after 10 min of the hydrolysis reaction. Further, the pH change could be determined with the naked eye from the color change of a pH indicator strip.
引用
收藏
页码:12134 / 12137
页数:4
相关论文
共 15 条
[1]   Gold nanoparticles mediated label-free capacitance detection of cardiac troponin I [J].
Bhalla, Vijayender ;
Carrara, Sandro ;
Sharma, Priyanka ;
Nangia, Yogesh ;
Suri, C. Raman .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01) :761-768
[2]   ACETYLCHOLINE .1. HYDROLYSIS BY HYDROGEN AND HYDROXYL ION [J].
BUTTERWORTH, J ;
ELEY, DD ;
STONE, GS .
BIOCHEMICAL JOURNAL, 1953, 53 (01) :30-34
[3]   One-step synthesis of superparamagnetic monodisperse porous Fe3O4 hollow and core-shell spheres [J].
Cheng, Wei ;
Tang, Kaibin ;
Qi, Yunxia ;
Sheng, Jie ;
Liu, Zhongpin .
JOURNAL OF MATERIALS CHEMISTRY, 2010, 20 (09) :1799-1805
[4]   Forecasting the Future of Cardiovascular Disease in the United States A Policy Statement From the American Heart Association [J].
Heidenreich, Paul A. ;
Trogdon, Justin G. ;
Khavjou, Olga A. ;
Butler, Javed ;
Dracup, Kathleen ;
Ezekowitz, Michael D. ;
Finkelstein, Eric Andrew ;
Hong, Yuling ;
Johnston, S. Claiborne ;
Khera, Amit ;
Lloyd-Jones, Donald M. ;
Nelson, Sue A. ;
Nichol, Graham ;
Orenstein, Diane ;
Wilson, Peter W. F. ;
Woo, Y. Joseph .
CIRCULATION, 2011, 123 (08) :933-944
[5]  
Arias Elizabeth, 2011, Natl Vital Stat Rep, V59, P1
[6]   Development of a surface plasmon resonance-based immunosensor for the rapid detection of cardiac troponin I [J].
Kwon, Young-Chul ;
Kim, Min-Gon ;
Kim, Eon-Mi ;
Shin, Yong-Beom ;
Lee, Seok-Ki ;
Lee, Sung Dong ;
Cho, Myung-Je ;
Ro, Hyeon-Su .
BIOTECHNOLOGY LETTERS, 2011, 33 (05) :921-927
[7]   Sensitive and Simultaneous Detection of Cardiac Markers in Human Serum Using Surface Acoustic Wave Immunosensor [J].
Lee, Joonhyung ;
Choi, Youn-Suk ;
Lee, Yeolho ;
Lee, Hun Joo ;
Lee, Jung Nam ;
Kim, Sang Kyu ;
Han, Kyung Yeon ;
Cho, Eun Chol ;
Park, Jae Chan ;
Lee, Soo Suk .
ANALYTICAL CHEMISTRY, 2011, 83 (22) :8629-8635
[8]   How to Interpret Elevated Cardiac Troponin Levels [J].
Mahajan, Vinay S. ;
Jarolim, Petr .
CIRCULATION, 2011, 124 (21) :2350-2354
[9]   Sensitive and real-time fiber-optic-based surface plasmon resonance sensors for myoglobin and cardiac troponin I [J].
Masson, JF ;
Obando, L ;
Beaudoin, S ;
Booksh, K .
TALANTA, 2004, 62 (05) :865-870
[10]   Cardiac troponin is the most effective translational safety biomarker for myocardial injury in cardiotoxicity [J].
O'Brien, Peter James .
TOXICOLOGY, 2008, 245 (03) :206-218