Relationship Between Preoperative Cone Beam Computed Tomography and Intraoperative Findings in Sinus Augmentation

被引:8
作者
Gurler, Gokhan [1 ]
Delilbasi, Cagri [1 ]
机构
[1] Istanbul Medipol Univ, Sch Dent, Dept Oral & Maxillofacial Surg, TR-34083 Unkapani Istanbul, Turkey
关键词
CBCT; perforation; sinus augmentation; sinus membrane; MAXILLARY SINUS; MEMBRANE PERFORATION; PREVALENCE; SEPTA; DIMENSIONS; ELEVATION; SURGERY;
D O I
10.11607/jomi.3797
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To investigate whether the presence of bony septum, thickness of sinus membrane (schneiderian membrane), and residual alveolar bone height affects membrane perforation and the duration of sinus augmentation. Materials and Methods: Preoperative cone beam computed tomography (CBCT) images obtained from patients undergoing lateral sinus augmentation were evaluated for the presence of bony septum, thickness of sinus membrane, and residual alveolar bone height. During the operation, membrane perforation and duration of surgery were noted. The Student t test was used to compare descriptive statistics (mean, standard error) and quantitative variables between groups. The Fisher exact. chi(2) test was used to compare the qualitative data, and Pearson correlation test was used to evaluate the correlation between data. P < .05 was considered significant. Results: Data from 57 patients were evaluated. Membrane perforation occurred in 14 patients included in the study and in 8 patients with sinus septum. A significant relationship was found between the presence of septum and membrane perforation during sinus augmentation (P = .014). However, the relationship among other CBCT and intraoperative findings was not significant. Conclusion: Presence of septum in the maxillary sinus increases the risk of membrane perforation, but does not extend the duration of the sinus augmentation.
引用
收藏
页码:1244 / 1248
页数:5
相关论文
共 29 条
[1]   The clinical significance of sinus membrane perforation during augmentation of the maxillary sinus [J].
Ardekian, L ;
Oved-Peleg, E ;
Mactei, EE ;
Peled, M .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (02) :277-282
[2]   Pre- and postoperative assessment of sinus grafting procedures using cone-beam computed tomography compared with panoramic radiographs [J].
Baciut, Mihaela ;
Hedesiu, Mihaela ;
Bran, Simion ;
Jacobs, Reinhilde ;
Nackaerts, Olivia ;
Baciut, Grigore .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (05) :512-516
[3]   Prevalence of maxillary sinus disease and abnormalities in patients scheduled for sinus lift procedures [J].
Beaumont, C ;
Zafiropoulos, GG ;
Rohmann, K ;
Tatakis, DN .
JOURNAL OF PERIODONTOLOGY, 2005, 76 (03) :461-467
[4]   Appropriate interslice gap for screening coronal paranasal sinus tomography for mucosal thickening [J].
Cagici, Can Alper ;
Yilmazer, Cuneyt ;
Hurcan, Cem ;
Ozer, Cem ;
Ozer, Fulya .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2009, 266 (04) :519-525
[5]   Relationship among Schneiderian Membrane, Underwood's Septa, and the Maxillary Sinus Inferior Border [J].
Cakur, Binali ;
Sumbullu, Muhammed Akif ;
Durna, Dogan .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (01) :83-87
[6]   Effect of Sinus Membrane Perforation on the Survival of Implants Placed in Combination With Osteotome Sinus Floor Elevation [J].
Ding, Xi ;
Zhu, Xing-hao ;
Wang, Hui-ming ;
Zhang, Xiu-hua .
JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (02) :E102-E104
[7]   Septa within the sinus: effect on elevation of the sinus floor [J].
Ella, Bruno ;
Noble, Reynald Da Costa ;
Lauverjat, Yves ;
Sedarat, Cyril ;
Zwetyenga, Narcisse ;
Siberchicot, Francois ;
Caix, Philippe .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2008, 46 (06) :464-467
[8]  
Esposito M, 2010, EUR J ORAL IMPLANTOL, V3, P7
[9]   Chronic sinusitis complicating sinus lift surgery [J].
Galli, SKD ;
Lebowitz, RA ;
Giacchi, RJ ;
Glickman, R ;
Jacobs, JB .
AMERICAN JOURNAL OF RHINOLOGY, 2001, 15 (03) :181-186
[10]   Characteristics and dimensions of the Schneiderian membrane: a radiographic analysis using cone beam computed tomography in patients referred for dental implant surgery in the posterior maxilla [J].
Janner, Simone F. M. ;
Caversaccio, Marco D. ;
Dubach, Patrick ;
Sendi, Pedram ;
Buser, Daniel ;
Bornstein, Michael M. .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (12) :1446-1453