Performance analysis of photovoltaic thermal (PVT) water collectors

被引:368
作者
Fudholi, Ahmad [1 ]
Sopian, Kamaruzzaman [1 ]
Yazdi, Mohammad H. [1 ]
Ruslan, Mohd Hafidz [1 ]
Ibrahim, Adnan [2 ]
Kazem, Hussein A. [3 ]
机构
[1] Univ Kebangsaan Malaysia, Solar Energy Res Inst, Bangi 43600, Selangor, Malaysia
[2] Univ Kuala Lumpur, Inst Prod Design & Mfg UniKL IPROM, Kuala Lumpur 56100, Malaysia
[3] Sohar Univ, Fac Engn, Sohar Pci 311, Oman
关键词
Electrical performance; Thermal performance; Photovoltaic thermal (PVT); PVT performance; Primary-energy saving efficiency; HEATING-SYSTEM; NATURAL CIRCULATION; DESIGN; FLOW;
D O I
10.1016/j.enconman.2013.11.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
The electrical and thermal performances of photovoltaic thermal (PVT) water collectors were determined under 500-800 W/m(2) solar radiation levels. At each solar radiation level, mass flow rates ranging from 0.011 kg/s to 0.041 kg/s were introduced. The PVT collectors were tested with respect to PV efficiency, thermal efficiency, and a combination of both (PVT efficiency). The results show that the spiral flow absorber exhibited the highest performance at a solar radiation level of 800 W/m2 and mass flow rate of 0.041 kg/s. This absorber produced a PVT efficiency of 68.4%, a PV efficiency of 13.8%, and a thermal efficiency of 54.6%. It also produced a primary-energy saving efficiency ranging from 79% to 91% at a mass flow rate of 0.011-0.041 kg/s. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:641 / 651
页数:11
相关论文
共 33 条
[1]   Life cycle cost assessment of building integrated photovoltaic thermal (BIPVT) systems [J].
Agrawal, Basant ;
Tiwari, G. N. .
ENERGY AND BUILDINGS, 2010, 42 (09) :1472-1481
[2]   Performance of a building integrated photovoltaic/thermal (BIPVT) solar collector [J].
Anderson, T. N. ;
Duke, M. ;
Morrison, G. L. ;
Carson, J. K. .
SOLAR ENERGY, 2009, 83 (04) :445-455
[3]  
[Anonymous], P SOL WORD C ISEC200
[4]  
[Anonymous], MENT, DOI DOI 10.1016/J
[5]   Artificial Neural Network based control for PV/T panel to track optimum thermal and electrical power [J].
Ben Ammar, Majed ;
Chaabene, Maher ;
Chtourou, Zied .
ENERGY CONVERSION AND MANAGEMENT, 2013, 65 :372-380
[6]   Design and dynamic simulation of a novel solar trigeneration system based on hybrid photovoltaic/thermal collectors (PVT) [J].
Calise, Francesco ;
d'Accadia, Massimo Dentice ;
Vanoli, Laura .
ENERGY CONVERSION AND MANAGEMENT, 2012, 60 :214-225
[7]   Characterization of a photovoltaic-thermal module for Fresnel linear concentrator [J].
Chemisana, D. ;
Ibanez, M. ;
Rosell, J. I. .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (10) :3234-3240
[8]   Computer modeling and experimental validation of a building-integrated photovoltaic and water heating system [J].
Chow, T. T. ;
He, W. ;
Chan, A. L. S. ;
Fong, K. F. ;
Lin, Z. ;
Ji, J. .
APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) :1356-1364
[9]   Photovoltaic-thermal collector system for domestic application [J].
Chow, T. T. ;
Ji, J. ;
He, W. .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (02) :205-209
[10]   An experimental study of facade-integrated photovoltaic/water-heating system [J].
Chow, T. T. ;
He, W. ;
Ji, J. .
APPLIED THERMAL ENGINEERING, 2007, 27 (01) :37-45