Evaluation of macular thickness measurements for detection of band atrophy of the optic nerve using optical coherence tomography

被引:61
作者
Moura, Frederico C.
Medeiros, Felipe A.
Monteiro, Mario L. R.
机构
[1] Univ Sao Paulo, Sch Med, Div Ophthalmol, Hosp Clin, Sao Paulo, Brazil
[2] Univ Calif San Diego, Dept Ophthalmol, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
基金
巴西圣保罗研究基金会;
关键词
D O I
10.1016/j.ophtha.2006.06.045
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the ability of optical coherence tomography (OCT) macular thickness parameters to differentiate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Design: Cross-sectional study. Participants: The study included 1 eye of each of 40 consecutive patients with BA of the optic nerve and permanent temporal hemianopic visual field (VF) defects owing to chiasmal compression and 31 age- and gender-matched healthy subjects. Methods: All patients underwent VF assessment with kinetic Goldmann perimetry and Humphrey 24-2 full-threshold standard automated perimetry (SAP). Macular and retinal nerve fiber layer (RNFL) thickness scans were obtained using the commercially available Stratus OCT. The severity of VF defect in patients with BA was evaluated by the temporal mean defect (TMD), calculated as the average of the 22 values of the temporal total deviation plot of the SAP 24-2 test, excluding the 2 points immediately above and below the blind spot. Main Outcome Measures: Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities were calculated for each parameter. Spearman's rank correlation coefficients were used to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss as measured by the TMD. Results: The macular thickness parameters related to the nasal hemiretina had the best performance to detect damage in BA eyes. No statistically significant difference (P = 0.19) was found between the ROC curve areas (AUCs) for the best macular thickness parameter (temporal/nasal macular thickness, AUC = 0.96) and the best RNFL parameter (average thickness, AUC = 0.99). Lower values of TMD, indicating more severe VF loss, were associated with lower macular thickness measurements. The highest correlation was observed for the parameter nasal average macular thickness (p = 0.693, R-2 = 48%, P < 0.001). Conclusion: Eyes with BA of the optic nerve show significant thinning of the retinal thickness on the nasal macular area, which is associated with the severity of VF damage in these eyes. Macular thickness measurements could potentially be used to evaluate the amount of ganglion cell loss in patients with BA of the optic nerve and could prove clinically useful for detection of damage and for monitoring these patients.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 18 条
[1]  
Baumann M, 1998, OPHTHALMIC SURG LAS, V29, P280
[2]   Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography [J].
Blumenthal, EZ ;
Williams, JM ;
Weinreb, RN ;
Girkin, CA ;
Berry, CC ;
Zangwill, LM .
OPHTHALMOLOGY, 2000, 107 (12) :2278-2282
[3]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[4]  
Greenfield DS, 2003, ARCH OPHTHALMOL-CHIC, V121, P41
[5]   Optical coherence tomography measurement of macular and nerve fiber layer thickness in normal and glaucomatous human eyes [J].
Guedes, V ;
Schuman, JS ;
Hertzmark, E ;
Wollstein, G ;
Correnti, A ;
Mancini, R ;
Lederer, D ;
Voskanian, S ;
Velazquez, L ;
Pakter, HM ;
Pedut-Kloizman, T ;
Fujimoto, JG ;
Mattox, C .
OPHTHALMOLOGY, 2003, 110 (01) :177-189
[6]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[7]   Optical coherence tomography to detect and manage retinal disease and glaucoma [J].
Jaffe, GJ ;
Caprioli, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (01) :156-169
[8]   The Humphrey optical coherence tomography scanner: quantitative analysis and reproducibility study of the normal human retinal nerve fibre layer [J].
Jones, AL ;
Sheen, NJL ;
North, RV ;
Morgan, JE .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (06) :673-677
[9]   Optical coherence tomography detects characteristic retinal nerve fiber layer thickness corresponding to band atrophy of the optic discs [J].
Kanamori, A ;
Nakamura, M ;
Matsui, N ;
Nagai, A ;
Nakanishi, Y ;
Kusuhara, S ;
Yamada, Y ;
Negi, A .
OPHTHALMOLOGY, 2004, 111 (12) :2278-2283
[10]   Analysis of macular volume in normal and glaucomatous eyes using optical coherence tomography [J].
Lederer, DE ;
Schuman, JS ;
Hertzmark, E ;
Heltzer, J ;
Velazques, LJ ;
Fujimoto, JG ;
Mattox, C .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (06) :838-843