Comparative study of intraocular lens implantation through 3.0 mm temporal clear corneal and superior scleral tunnel self-sealing incisions

被引:36
作者
Oshima, Y
Tsujikawa, K
Oh, A
Harino, S
机构
[1] Department of Ophthalmology, Osaka Rosai Hospital, Sakai City, Osaka 591, 1179-3, Nagasone-cho
关键词
D O I
10.1016/S0886-3350(97)80178-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the clinical outcome of phacoernulsification and foldable silicone intraocular lens (IOL) implantation through a 3.0 mm temporal clear corneal incision and a 3.0 mm superior scleral tunnel incision. Setting: Department of Ophthalmology, Yodogawa Christian Hospital, Osaka, Japan. Methods: Eighty cataractous eyes of 78 patients with pre-existing against-the-rule (ATR) astigmatism were recruited for this prospective, randomized study. The patients were assigned to one of the two groups. Data on uncorrected and corrected visual acuities, keratometry, flare intensity measurement, and central cornea endothelial cell count were evaluated preoperatively and at 2 days, 1 week, and 1 and 3 months postoperatively. Results: Although the pre-existing keratometric cylinder decreased in the temporal clear corneal incision group and increased in the superior scleral tunnel incision group, the amount of cylinder shift was not significantly different. Mean scalar shift of keratometric cylinder in the corneal incision group was 1.19 diopters (D) at 2 days postoperatively, 0.86 D at 1 week, and 0.56 D at 3 months and in the scleral incision group, 1.09 D at 2 days, 0.76 D at 1 week, and 0.65 D at 3 months. Eighty percent of the eyes in each group achieved an uncorrected visual acuity of 20/40 or better from the second day postoperatively. No statistically significant difference in visual rehabilitation or other parameters was noted bl tween the groups throughout the study. Complications including corneal endothelial cell loss and wound incompetence requiring suturing were observed in the temporal clear corneal incision group. Conclusions: Both incisions offered satisfactory clinical results, but the superior scleral tunnel incision resulted in fewer complications. Minimal corneal keratometric change induced by a 3.0 mm incision was not related to uncorrected visual rehabilitation.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 25 条
[1]  
AMON M, 1995, EUR J IMPLANT REFRAC, V7, P229
[2]   REDUCTION OF POSTOPERATIVE AGAINST-THE-RULE ASTIGMATISM BY LATERAL INCISION TECHNIQUE [J].
AXT, JC ;
MCCAFFERY, JM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (03) :380-386
[3]   KERATOMETRIC CYLINDER AND VISUAL PERFORMANCE FOLLOWING PHACOEMULSIFICATION AND IMPLANTATION WITH SILICONE SMALL-INCISION OR POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES [J].
BRINT, SF ;
OSTRICK, DM ;
BRYAN, JE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (01) :32-36
[4]  
CRAVY TV, 1979, OPHTHALMIC SURG LAS, V10, P38
[5]  
Dick HB, 1996, J CATARACT REFR SURG, V22, P63
[6]   RELATIVE STABILITY OF CLEAR CORNEAL INCISIONS IN A CADAVER EYE MODEL [J].
ERNEST, PH ;
FENZL, R ;
LAVERY, KT ;
SENSOLI, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (01) :39-42
[7]   RELATIVE STRENGTH OF SCLERAL CORNEAL AND CLEAR CORNEAL INCISIONS CONSTRUCTED IN CADAVER EYES [J].
ERNEST, PH ;
LAVERY, KT ;
KIESSLING, LA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (06) :626-629
[8]   RELATIVE STRENGTH OF CATARACT INCISIONS IN CADAVER EYES [J].
ERNEST, PH ;
KIESSLING, LA ;
LAVERY, KT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 :668-671
[9]   ASTIGMATIC DECAY FOLLOWING SMALL-INCISION, SELF-SEALING CATARACT-SURGERY [J].
FEIL, SH ;
CRANDALL, AS ;
OLSON, RJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01) :40-43
[10]  
FINE IH, 1993, CLEAR CORNEAL CATARA