Weighted Data Fusion Use for Ruthenium Dioxide Thin Film pH Array Electrodes

被引:18
作者
Liao, Yi-Hung [1 ,2 ]
Chou, Jung-Chuan [3 ]
机构
[1] Natl Yunlin Univ Sci & Technol, Grad Sch Engn Sci & Technol, Touliu 64002, Yunlin, Taiwan
[2] Transworld Inst Technol, Dept Informat Management, Touliu 64002, Yunlin, Taiwan
[3] Natl Yunlin Univ Sci & Technol, Dept Elect Engn, Touliu 64002, Yunlin, Taiwan
关键词
Array sensor; data fusion; ion selective electrode; ruthenium dioxide; weighted coefficient; VAPOR-DEPOSITION; RUO2; COMPOSITE; OXIDE; ACID;
D O I
10.1109/JSEN.2009.2024045
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Data fusion is a useful statistical method that can be applied to multiple sensors or array sensors in many fields. The pH value is a very important parameter in clinical diagnosis, industrial wastewater treatment using a hydrogen ion selective electrode or pH meter. In this study, the examined data fusion methods consist of the arithmetic average and weighted data fusion coefficients used to process the measured pH data. A ruthenium dioxide (RuO2) pH electrode was prepared. RuO2 thin films were deposited onto silicon substrate using a sputtering system. Eight RuO2 hydrogen ion selective electrodes were used to form pH array sensors. From the measurement process, we can simultaneously obtain eight data sets. The experimental results, using the data fusion weighted coefficients obtained a good measurement result even when an individual sensor failed within the array sensors.
引用
收藏
页码:842 / 848
页数:7
相关论文
共 29 条
[1]  
BARDWAJ AA, 2008, P IEEE INT C SIGN PR, P250
[2]   Influence of DL-β-hydroxybutyric acid on cell proliferation and calcium influx [J].
Cheng, S ;
Wu, Q ;
Yang, F ;
Xu, M ;
Leski, M ;
Chen, GQ .
BIOMACROMOLECULES, 2005, 6 (02) :593-597
[3]   Fabrication and characterization of SnO2-RuO2 composite anode thin film for lithium ion batteries [J].
Choi, SH ;
Kim, JS ;
Yoon, YS .
ELECTROCHIMICA ACTA, 2004, 50 (2-3) :547-552
[4]   Sensing characteristics of ruthenium films fabricated by radio frequency sputtering [J].
Chou, JC ;
Liu, SI ;
Chen, SH .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (03) :1403-1408
[5]   Coulometric micro-titrator with a ruthenium dioxide pH-electrode [J].
Colombo, C ;
Kappes, T ;
Hauser, PC .
ANALYTICA CHIMICA ACTA, 2000, 412 (1-2) :69-75
[6]   A new method to prepare RuO2.xH2O/carbon nanotube composite for electrochemical capacitors [J].
Deng, GH ;
Xiao, X ;
Chen, JH ;
Zeng, XB ;
He, DL ;
Kuang, YF .
CARBON, 2005, 43 (07) :1566-1569
[7]   The research of data fusion method for sample mean random weighting estimation [J].
Gao, Shesheng ;
Feng, Zhihua ;
Li, Huaxing .
2006 IEEE INTERNATIONAL CONFERENCE ON INFORMATION ACQUISITION, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2006, :584-588
[8]   Tracking filter and multi-sensor data fusion [J].
Girija, G ;
Raol, JR ;
Raj, RA ;
Kashyap, S .
SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2000, 25 (2) :159-167
[9]   Spray deposited amorphous RUO2 for an effective use in electrochemical supercapacitor [J].
Gujar, T. P. ;
Shinde, V. R. ;
Lokhande, C. D. ;
Kim, Woo-Young ;
Jung, Kwang-Deog ;
Joo, Oh-Shim .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (03) :504-510
[10]   Fusion tracking algorithm based on stochastic approximation [J].
Guo, Liwei ;
Chen, Xueguang ;
Hu, Shiqiang .
2006 IEEE INTERNATIONAL CONFERENCE ON INFORMATION ACQUISITION, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2006, :802-807