Simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method for the quantification of lacidipine in human plasma

被引:31
作者
Ramakrishna, NVS [1 ]
Vishwottam, KN [1 ]
Puran, S [1 ]
Manoj, S [1 ]
Santosh, M [1 ]
Koteshwara, M [1 ]
机构
[1] Suven Life Sci Ltd, Biopharmaceut Res, Hyderabad 500034, Andhra Pradesh, India
来源
JOURNAL OF MASS SPECTROMETRY | 2004年 / 39卷 / 07期
关键词
liquid chromatography/electrospray ionization tandem mass spectrometry; multiple reaction monitoring; lacidipine; amlodipine; plasma;
D O I
10.1002/jms.664
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C-18 reversed-phase chromatographic column by isocratic elution with 20 mm ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:824 / 832
页数:9
相关论文
共 25 条
[1]  
ALBINI A, 1998, DRUGS PHOTOCHEMISTRY, P1
[2]  
[Anonymous], 2001, Guidance for industry, bioanalytical method validation
[3]  
[Anonymous], 1996, MART EXTR PHARM, P898
[4]   AUTOMATION AND VALIDATION OF THE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC-RADIOIMMUNOASSAY METHOD FOR THE DETERMINATION OF LACIDIPINE IN PLASMA [J].
BRAGGIO, S ;
SARTORI, S ;
ANGERI, F ;
PELLEGATTI, M .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 669 (02) :383-389
[5]  
Dass C, 1999, CURR ORG CHEM, V3, P193
[6]  
EVANS GL, 1990, ANAL DRUGS METABOLIT, P285
[7]  
FILIPPIS P, 2002, J PHARM BIOMED ANAL, V27, P803
[8]  
GREENHILL JV, 1996, PHOTOSTABILITY DRUGS, P83
[9]   Endothelial dysfunction, hypertension and atherosclerosis: A review of the effects of lacidipine [J].
Haller H. ;
Cosentino F. ;
Luscher T.F. .
Drugs in R & D, 2002, 3 (5) :311-323
[10]  
HARTMANN C, 1995, EXPERIENCE CHROMATOG, P331