Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison

被引:28
|
作者
Krazinski, Aleksander W. [1 ]
Meinel, Felix G. [1 ,2 ]
Schoepf, U. Joseph [1 ,3 ]
Silverman, Justin R. [1 ]
Canstein, Christian [4 ]
De Cecco, Carlo N. [1 ,5 ]
Geyer, Lucas L. [1 ,2 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[2] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[3] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA
[4] Siemens Healthcare, CT Div, Malvern, PA USA
[5] Univ Rome Sapienza Polo Pontino, Dept Radiol Sci Oncol & Pathol, Latina, Italy
关键词
CT angiography; Cardiac CT; Aorta; Radiation dose; Tube potential; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; DUAL-SOURCE CT; CORONARY-ANGIOGRAPHY; POTENTIAL SELECTION; CURRENT MODULATION; ABDOMINAL-AORTA; PEDIATRIC CT; CHEST CT; KILOVOLTAGE; REDUCTION;
D O I
10.1007/s00330-014-3312-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the effect of automated tube voltage selection on radiation dose and image quality at cardiovascular CT angiography (CTA). We retrospectively analysed paired studies in 72 patients (41 male, 60.5 +/- 16.5 years), who had undergone CTA acquisitions of the heart or aorta both before and after the implementation of an automated x-ray tube voltage selection algorithm (ATVS). All other parameters were kept identical between the two acquisitions. Subjective image quality (IQ) was rated and objective IQ was measured by image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM). Image quality parameters and effective dose were compared between acquisitions. Overall subjective image quality improved with the percentage of cases scored as adequate or higher increasing from 79 % to 92 % after implementation of ATVS (P = 0.03). SNR (14.1 +/- 5.9, 15.7 +/- 6.1, P = 0.009), CNR (11.6 +/- 5.3, 13.2 +/- 5.6, P = 0.011), and FOM (19.9 +/- 23.3, 43.8 +/- 51.1, P < 0.001) were significantly higher after implementation of ATVS. Mean image noise (24.1 +/- 8.4 HU, 22.7 +/- 7.1 HU, P = 0.048) and mean effective dose (10.6 +/- 5.9 mSv, 8.8 +/- 5.0 mSv, P = 0.003) were significantly lower after implementation of ATVS. Automated tube voltage selection can operator-independently optimize cardiovascular CTA image acquisition parameters with improved image quality at reduced dose. aEuro cent Automatic tube voltage selection optimizes tube voltage for each individual patient. aEuro cent In this population, overall radiation dose decreased while image quality improved. aEuro cent This tool may become valuable for improving dose/quality ratio.
引用
收藏
页码:2677 / 2684
页数:8
相关论文
共 50 条
  • [41] Diagnostic yield of 90-kVp low-tube-voltage carotid and intracerebral CT-angiography: effects on radiation dose, image quality and diagnostic performance for the detection of carotid stenosis
    Leithner, Doris
    Wichmann, Julian L.
    Mahmoudi, Scherwin
    Martin, Simon S.
    Albrecht, Moritz H.
    Vogl, Thomas J.
    Scholtz, Jan-Erik
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1086)
  • [42] Improvement of Image Quality at Low-Radiation Dose and Low-Contrast Material Dose Abdominal CT in Patients With Cirrhosis: Intraindividual Comparison of Low Tube Voltage With Iterative Reconstruction Algorithm and Standard Tube Voltage
    Namimoto, Tomohiro
    Oda, Seitaro
    Utsunomiya, Daisuke
    Shimonobo, Toshiaki
    Morita, Sosuke
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (04) : 495 - 501
  • [43] Application of 80-kVp tube voltage, low-concentration contrast agent and iterative reconstruction in coronary CT angiography: evaluation of image quality and radiation dose
    Wu, Qiyong
    Wang, Yong
    Kai, Huihua
    Wang, Tao
    Tang, Xiaoqiang
    Wang, Xiaoqin
    Pan, Changjie
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B50 - B55
  • [44] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Pan, Yue-ying
    Zhou, Shu-chang
    Wang, Yu-jin
    Li, Qian
    Zhu, Ting-ting
    Liu, Chun-xia
    Guan, Han-xiong
    CURRENT MEDICAL SCIENCE, 2020, 40 (01) : 178 - 183
  • [45] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Yue-ying Pan
    Shu-chang Zhou
    Yu-jin Wang
    Qian Li
    Ting-ting Zhu
    Chun-xia Liu
    Han-xiong Guan
    Current Medical Science, 2020, 40 : 178 - 183
  • [46] Image Quality of 3rd Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose
    Wenz, Holger
    Maros, Mate E.
    Meyer, Mathias
    Foerster, Alex
    Haubenreisser, Holger
    Kurth, Stefan
    Schoenberg, Stefan O.
    Flohr, Thomas
    Leidecker, Christianne
    Groden, Christoph
    Scharf, Johann
    Henzler, Thomas
    PLOS ONE, 2015, 10 (08):
  • [47] Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol
    Jiyeon Lim
    Eun-Ah Park
    Whal Lee
    Hackjoon Shim
    Jin Wook Chung
    The International Journal of Cardiovascular Imaging, 2015, 31 : 23 - 30
  • [48] Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose
    Scholtz, Jan-Erik
    Wichmann, Julian L.
    Huesers, Kristina
    Albrecht, Moritz H.
    Beeres, Martin
    Bauer, Ralf W.
    Vogl, Thomas J.
    Bodelle, Boris
    EUROPEAN RADIOLOGY, 2016, 26 (08) : 2623 - 2631
  • [49] Effect of reduced x-ray tube voltage, low iodine concentration contrast medium, and sinogram-affirmed iterative reconstruction on image quality and radiation dose at coronary CT angiography: Results of the prospective multicenter REALISE trial
    Yin, Wei-Hua
    Lu, Bin
    Gao, Jian-Bo
    Li, Pei-Ling
    Sun, Kai
    Wu, Zhi-Feng
    Yang, Wen-Jie
    Zhang, Xiao-Qin
    Zheng, Min-Wen
    McQuiston, Andrew D.
    Meinel, Felix G.
    Schoepf, Uwe Joseph
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (03) : 215 - 224
  • [50] Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: Feasibility, image quality, radiation dose, and effect of iterative reconstruction
    Hell, Michaela M.
    Bittner, Daniel
    Schuhbaeck, Annika
    Muschiol, Gerd
    Brand, Michael
    Lell, Michael
    Uder, Michael
    Achenbach, Stephan
    Marwan, Mohamed
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (06) : 418 - 425