Validity of D-dimer tests in the diagnosis of deep vein thrombosis: a prospective comparative study of three quantitative assays

被引:22
|
作者
Larsen, TB
Stoffersen, E
Christensen, CS
Laursen, B
机构
[1] Aalborg Hosp, Dept Clin Biochem, Sect Thrombosis & Hemostasis, Aalborg, Denmark
[2] Aalborg Hosp, Dept Radiol, Aalborg, Denmark
[3] Aalborg Hosp, Dept Haematol, Aalborg, Denmark
关键词
D-dimer; deep vein thrombosis; diagnosis; diagnostic accuracy; prospective study; sensitivity; specificity; ultrasonography;
D O I
10.1046/j.1365-2796.2002.00998.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To assess the diagnostic reliability of a new quantitative D-dimer assay (VIDAS New((R)) ) and an established quick test (Nycocard((R)) D-dimer assay) in the diagnosis of deep vein thrombosis (DVT) compared with ultrasonography. A third assay (Auto Dimer((R)) ) became available during sample collection and has been included in the final assessment. The diagnostic performance of the Auto Dimer((R)) assay was evaluated on three different coagulation analysers. Design. A clinical prospective study of patients admitted to hospital for evaluation of DVT. Setting. The admission ward at Aalborg Hospital. Subjects. A total of 113 outpatients with suspected DVT. Main outcome measures. Compression ultrasonography was used as the reference method for a diagnosis of DVT and compared with different D-dimer assays. The results were expressed as sensitivity, specificity, positive predictive value and negative predictive value (NPV). Results. Deep vein thrombosis was established in 49 patients (43%). Two D-dimer assays (VIDAS New((R)) and Auto Dimer((R)) ) showed sensitivities of 90 and 88%, specificities of 42 and 44%, and NPV's of 85 and 83%, respectively. The Nycocard((R)) D-dimer assay showed a sensitivity of 63%, specificity of 67% and NPV of 71%. Conclusions. The diagnostic performance of VIDAS New((R)) and the Auto Dimer((R)) D-dimer assays is almost identical, but this study suggests that neither of the D-dimer assays is suitable as the only screening method for DVT, in a situation with a high pretest probability of DVT. This call for a differential strategy that distinguishes between cases of low and high clinical probability using either a D-dimer test or ultrasonography.
引用
收藏
页码:36 / 40
页数:5
相关论文
共 50 条
  • [41] Residual Vein Thrombosis and D-Dimer for Optimizing Duration of Anticoagulation in Idiopathic Deep Vein Thrombosis
    Malato, Alessandra
    Saccullo, Giorgia
    Iorio, Alfonso
    Ageno, Walter
    Siragusa, Sergio
    CURRENT PHARMACEUTICAL DESIGN, 2010, 16 (31) : 3483 - 3486
  • [42] Quantification of D-dimer using a new fully automated assay:: its application for the diagnosis of deep vein thrombosis
    Villa, P
    Ferrando, F
    Serra, J
    Faus, H
    Mira, Y
    Vayá, A
    Aznar, J
    HAEMATOLOGICA, 2000, 85 (05) : 520 - 524
  • [43] Thrombotic burden, D-dimer levels and complete compression ultrasound for diagnosis of acute symptomatic deep vein thrombosis of the lower limbs
    Cosmi, Benilde
    Legnani, Cristina
    Cini, Michela
    Tomba, Sara
    Migliaccio, Ludovica
    Borgese, Laura
    Sartori, Michelangelo
    Palareti, Gualtiero
    THROMBOSIS RESEARCH, 2022, 213 : 163 - 169
  • [44] Diagnostic Accuracy of a New d-Dimer Assay (Sclavo Auto d-Dimer) for Exclusion of Deep Vein Thrombosis in Symptomatic Outpatients
    Legnani, Cristina
    Cini, Michela
    Frascaro, Mirella
    Rodorigo, Giuseppina
    Sartori, Michelangelo
    Cosmi, Benilde
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2017, 23 (03) : 221 - 228
  • [45] Combination of rapid D-Dimer testing and simple clinical model for the diagnosis of deep vein thrombosis
    Arrivé, L
    Monnier-Cholley, L
    Serru, V
    Carrat, F
    Vassal, T
    Dahan, H
    Bouras, T
    Jomaah, N
    Le Hir, P
    Azizi, L
    Belkacem, A
    Lewin, M
    Tubiana, J
    Robert, A
    JOURNAL DE RADIOLOGIE, 2002, 83 (03): : 337 - 340
  • [46] Sparing Ultrasound in Emergency Department Patients with Suspected Deep Vein Thrombosis by Using Clinical Scores and D-Dimer Testing
    Gaitini, Diana
    Khoury, Rasha
    Israelit, Shlomo
    Beck-Razi, Nira
    JOURNAL OF CLINICAL ULTRASOUND, 2016, 44 (04) : 231 - 239
  • [47] The diagnostic performance of APC-PCI complex determination compared to d-dimer in the diagnosis of deep vein thrombosis
    Elf, Johan L.
    Strandberg, Karin
    Svensson, Peter J.
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2010, 29 (04) : 465 - 470
  • [48] Comparison of six D-dimer assays for the detection of clinically suspected deep venous thrombosis of the lower extremities
    Boeer, Klas
    Siegmund, Robert
    Schmidt, Dirk
    Deufel, Thomas
    Kiehntopf, Michael
    BLOOD COAGULATION & FIBRINOLYSIS, 2009, 20 (02) : 141 - 145
  • [49] The Utility of Quantitative D-Dimer Assay as a Biomarker in the Diagnosis and Exclusion of Cerebral Venous Sinus Thrombosis
    Soni, Dipesh
    Pannu, Ashok Kumar
    Saroch, Atul
    Bhatia, Vikas
    Ahluwalia, Jasmina
    Singh, Rajveer
    Jain, Arihant
    INDIAN JOURNAL OF HEMATOLOGY AND BLOOD TRANSFUSION, 2024, 40 (01) : 122 - 129
  • [50] Deep vein thrombosis after total hip arthroplasty in Korean patients and D-dimer as a screening tool
    Yoo, Myung-Chul
    Cho, Yoon-Je
    Ghanem, Elie
    Ramteke, Alankar
    Kim, Kang-Il
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (07) : 887 - 894