Potentiometric detection of carboxylic acids by flow injection analysis using a tungsten oxide electrode

被引:14
作者
Chen, ZL
Alexander, PW
机构
[1] Department of Physical Science, Univ. of Tasmania at Launceston, Launceston, Tasmania 7250
关键词
flow injection; carboxylic acids; tungsten oxide electrode; potentiometry;
D O I
10.1016/0003-2670(96)00258-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric flow injection (PFI) analysis of carboxylic acids based on a tungsten oxide electrode is described. The electrode is shown to offer high sensitivity and a stable baseline for the detection of carboxylic acids. The parameters affecting the electrode response such as the concentration of buffer, the pH and flow rate were studied in detail. The electrode exhibited a linear response for propionic acid in the concentration range of 2.5x10(-4)M-5x10(-5)M using a 5x10(-4)M phosphate buffer at pH 6.5 as a carrier. The detection limits were found to be in the range of 1.0x10(-5)M-5x10(-5)M with a 20 mu l injection.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 50 条
  • [41] Detection of S-enantiomers of cilazapril, pentopril and trandolapril using a potentiometric, enantioselective membrane electrode
    Stefan, RI
    van Staden, JKF
    Aboul-Enein, HY
    ELECTROANALYSIS, 1999, 11 (03) : 192 - 194
  • [42] A novel planar miniaturized potentiometric sensor for flow injection analysis of nitrates in wastewaters, fertilizers and pharmaceuticals
    Hassan, Saad S. M.
    Sayour, H. E. M.
    Al-Mehrezi, Saeed S.
    ANALYTICA CHIMICA ACTA, 2007, 581 (01) : 13 - 18
  • [43] Flow injection analysis of pyrogallol with enhanced electrochemiluminescent detection
    Sun, YG
    Cui, H
    Lin, XQ
    Li, YH
    Zhao, HZ
    ANALYTICA CHIMICA ACTA, 2000, 423 (02) : 247 - 253
  • [44] AMPEROMETRIC DETECTION OF AMINO-ACIDS IN A FLOW-INJECTION SYSTEM WITH A NICKEL(II)-MODIFIED ELECTRODE WITH AN EASTMAN-AQ POLYMER FILM
    LIU, AH
    WANG, EK
    ANALYTICA CHIMICA ACTA, 1993, 280 (02) : 223 - 229
  • [45] Flow injection based microfluidic device with carbon nanotube electrode for rapid salbutamol detection
    Karuwan, Chanpen
    Wisitsoraat, Anurat
    Maturos, Thitima
    Phokharatkul, Disayut
    Sappat, Assawapong
    Jaruwongrungsee, Kata
    Lomas, Tanom
    Tuantranont, Adisorn
    TALANTA, 2009, 79 (04) : 995 - 1000
  • [46] Polarographic study of acrolein and its determination by flow injection with amperometric detection at a mercury electrode
    Rodriguez, IN
    Leyva, JAM
    Hidalgo, JL
    deCisneros, H
    TALANTA, 1996, 43 (07) : 1117 - 1124
  • [47] Potentiometric flow injection system for determination of reductants using a polymeric membrane permanganate ion-selective electrode based on current-controlled reagent delivery
    Song, Wenjing
    Ding, Jiawang
    Liang, Rongning
    Qin, Wei
    ANALYTICA CHIMICA ACTA, 2011, 704 (1-2) : 68 - 72
  • [48] Determination of sulfite by flow injection analysis using a poly [Ni-(protoporphyrin IX)] chemically modified electrode
    Carballo, R
    Dall'Orto, VC
    Lo Balbo, A
    Rezzano, I
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (02) : 155 - 161
  • [49] An investigation of glutathione-platinum(II) interactions by means of the flow injection analysis using glassy carbon electrode
    Zitka, Ondrej
    Huska, Dalibor
    Krizkova, Sona
    Adam, Vojtech
    Chavis, Grace J.
    Trnkova, Libuse
    Horna, Ales
    Hubalek, Jaromir
    Kizek, Rene
    SENSORS, 2007, 7 (07) : 1256 - 1270
  • [50] The determination of levofloxacin by flow injection analysis using UV detection, potentiometry, and conductometry in pharmaceutical preparations
    Altiokka, G
    Atkosar, Z
    Can, NO
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) : 881 - 885