Potentiometric detection of carboxylic acids by flow injection analysis using a tungsten oxide electrode

被引:14
作者
Chen, ZL
Alexander, PW
机构
[1] Department of Physical Science, Univ. of Tasmania at Launceston, Launceston, Tasmania 7250
关键词
flow injection; carboxylic acids; tungsten oxide electrode; potentiometry;
D O I
10.1016/0003-2670(96)00258-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric flow injection (PFI) analysis of carboxylic acids based on a tungsten oxide electrode is described. The electrode is shown to offer high sensitivity and a stable baseline for the detection of carboxylic acids. The parameters affecting the electrode response such as the concentration of buffer, the pH and flow rate were studied in detail. The electrode exhibited a linear response for propionic acid in the concentration range of 2.5x10(-4)M-5x10(-5)M using a 5x10(-4)M phosphate buffer at pH 6.5 as a carrier. The detection limits were found to be in the range of 1.0x10(-5)M-5x10(-5)M with a 20 mu l injection.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 50 条
  • [31] Trace measurements of nucleic acids using flow injection amperometry
    Wang, J
    Chen, L
    Chicharro, M
    ANALYTICA CHIMICA ACTA, 1996, 319 (03) : 347 - 352
  • [32] POTENTIOMETRIC FLOW-ANALYSIS DEVICE USING MEMBRANE-COATED CARBON ROD ION-SELECTIVE ELECTRODE DETECTORS
    WANG, E
    KAMATA, S
    ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 399 - 404
  • [33] A simple and selective flow-injection potentiometric method for determination of iodide based on a coated glassy carbon electrode sensor
    Beheshti, Saeed S.
    Amini, Mohammad K.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (10): : 778 - 787
  • [34] Determination of methyltestosterone using flow injection with chemiluminescence detection
    Xie, ZH
    Ouyang, XQ
    Guo, LQ
    Lin, XC
    Chen, GN
    LUMINESCENCE, 2005, 20 (03) : 231 - 235
  • [35] Determination of norfloxacin by flow injection analysis with chemiluminescence detection
    Sun, Han-wen
    Li, Li-qing
    Chen, Xue-yan
    Shi, Hong-mei
    Lue, Yun-kai
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2006, 51 (02): : 100 - 107
  • [36] Determination of hydroxycamptothecinum by flow injection analysis with chemiluminescence detection
    Li Liqing
    Lin, Guan
    Ming, Su
    Sun Hanwen
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2007, 21 (06) : 356 - 362
  • [37] Determination of codeine in process streams using flow-injection analysis with chemiluminescence detection
    Barnett, NW
    Bowser, TA
    Gerardi, RD
    Smith, B
    ANALYTICA CHIMICA ACTA, 1996, 318 (03) : 309 - 317
  • [38] Using PVC ion-selective electrodes for the potentiometric flow injection analysis of distigmine in its pharmaceutical formulation and biological fluids
    Issa, Yousry M.
    Khorshid, Amal F.
    JOURNAL OF ADVANCED RESEARCH, 2011, 2 (01) : 25 - 34
  • [39] Cobalt oxide nanostructure-modified glassy carbon electrode as a highly sensitive flow injection amperometric sensor for the picomolar detection of insulin
    Abdollah Salimi
    Rahman Hallaj
    Journal of Solid State Electrochemistry, 2012, 16 : 1239 - 1246
  • [40] Cobalt oxide nanostructure-modified glassy carbon electrode as a highly sensitive flow injection amperometric sensor for the picomolar detection of insulin
    Salimi, Abdollah
    Hallaj, Rahman
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (03) : 1239 - 1246