Potentiometric detection of carboxylic acids by flow injection analysis using a tungsten oxide electrode

被引:14
作者
Chen, ZL
Alexander, PW
机构
[1] Department of Physical Science, Univ. of Tasmania at Launceston, Launceston, Tasmania 7250
关键词
flow injection; carboxylic acids; tungsten oxide electrode; potentiometry;
D O I
10.1016/0003-2670(96)00258-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric flow injection (PFI) analysis of carboxylic acids based on a tungsten oxide electrode is described. The electrode is shown to offer high sensitivity and a stable baseline for the detection of carboxylic acids. The parameters affecting the electrode response such as the concentration of buffer, the pH and flow rate were studied in detail. The electrode exhibited a linear response for propionic acid in the concentration range of 2.5x10(-4)M-5x10(-5)M using a 5x10(-4)M phosphate buffer at pH 6.5 as a carrier. The detection limits were found to be in the range of 1.0x10(-5)M-5x10(-5)M with a 20 mu l injection.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 50 条
  • [21] FLOW-INJECTION DETERMINATION OF NOVALGIN USING AMPEROMETRIC DETECTION AT A GLASSY-CARBON ELECTRODE
    PEREZRUIZ, T
    LOZANO, CM
    TOMAS, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (09) : 1109 - 1113
  • [22] Flow-injection potentiometric determination of free cadmium ions with a cadmium ion-selective electrode
    Trojanowicz, M
    Alexander, PW
    Brynn Hibbert, D
    ANALYTICA CHIMICA ACTA, 1998, 370 (2-3) : 267 - 278
  • [23] Detection of amino acids at conducting electroactive polymer modified electrodes using flow injection analysis .2. Use of microelectrodes
    Akhtar, P
    Too, CO
    Wallace, GG
    ANALYTICA CHIMICA ACTA, 1997, 339 (03) : 211 - 223
  • [24] Speciation analysis of CrIII-CrVI using flow injection analysis with fluorimetric detection
    Paleologos, EK
    Lafis, SI
    Tzouwara-Karayanni, SM
    Karayannis, MI
    ANALYST, 1998, 123 (05) : 1005 - 1009
  • [25] Conventional and planar chip sensors for potentiometric assay of uric acid in biological fluids using flow injection analysis
    Kamel, Ayman H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 45 (02) : 341 - 348
  • [26] Fabrication of a nitrate selective electrode for determination of nitrate in fertilizers by using flow injection analysis system
    Chaneam, Sumonmarn
    Taweetong, Waritta
    Kaewyai, Kampanart
    Thienwong, Pheeraphon
    Takaew, Aekgaraj
    Chaisuksant, Rasamee
    11TH ASIAN CONFERENCE ON CHEMICAL SENSORS, 2016, 20 : 73 - 75
  • [27] Potentiometric detection of organic acids in liquid chromatography using conducting oligomer electrodes
    Poels, I
    Nagels, LJ
    Verreyt, G
    Geise, HJ
    ANALYTICA CHIMICA ACTA, 1998, 370 (2-3) : 105 - 113
  • [28] NITRATE ION-SELECTIVE ELECTRODE AS REFERENCE ELECTRODE FOR FLOW-INJECTION ANALYSIS
    ALONSOCHAMARRO, J
    BARTROLI, J
    JIMENEZ, C
    ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 419 - 423
  • [29] Determination of eugenol using flow injection analysis with potassium permanganate chemiluminescence detection
    Xu, Hun
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 5109 - 5112
  • [30] Flow Injection Potentiometric Determination of Terazosin Hydrochloride Using Modified Carbon Paste Electrodes
    Zayed, Sayed I. M.
    Khalil, Mohamed M.
    Issa, Yousry M.
    Khalefa, Huda R.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (05): : 2327 - 2340