Mycotic aneurysm caused by Edwardsiella tarda successfully treated with stenting and suppressive antibiotic therapy: a case report and systematic review

被引:8
作者
Ebisawa, Kei Furui [1 ]
Nishimura, Sho [1 ]
Yamamoto, Shungo [2 ]
Ohji, Goh [1 ]
Iwata, Kentaro [1 ]
机构
[1] Kobe Univ Hosp, Div Infect Dis, Chuo Ku, 7-5-2 Kusunoki Cho, Kobe, Hyogo 6500017, Japan
[2] Kyoto Univ Hosp, Integrated Clin Educ Ctr, Sakyo Ku, 54 Kawaharacho, Kyoto 6068507, Japan
关键词
Edwardsiella tarda; Cirrhosis; Mycotic aneurysm; Stent graft; Suppressive antibiotic therapy; GRAFT TREATMENT; INFECTION; AGENTS;
D O I
10.1186/s12941-018-0273-x
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Mycotic aneurysm is an uncommon disease which could be fatal without appropriate treatment. Although standard therapy for mycotic aneurysms consists of resection of the infected aorta and in situ graft replacement, some treat with endovascular stent-grafting because patients may not tolerate graft replacement due to underlying diseases. There are 6 more reported cases of mycotic aneurysm caused by Edwardsiella tarda. With the exception of our case, all underwent resection and debridement of the infected aorta or vascular prosthesis. Herein we report the first case ever of mycotic aneurysm caused by E. tarda, successfully treated with stenting and suppressive antibiotic therapy without resection of the infected aorta. Case presentation: A 65-year-old Japanese woman with cirrhosis and hepatocellular carcinoma complained of fatigue. Her work up revealed a ruptured aneurysm of the descending aorta. She went through endovascular stentgraft placement. Edwardsiella tarda grew from blood cultures, which led to the diagnosis of mycotic aneurysm. Edwardsiella tarda is a Gram negative bacillus which rarely causes infections in humans. In the case of bacteremia, its mortality is reported to be very high and all reported cases with mycotic aneurysm caused by E. tarda ended up with resection of the infected aorta. Conclusion: Our case shows that in the case of mycotic aneurysm caused by E. tarda, endovascular stent-graft placement could be an alternative to in situ graft replacement.
引用
收藏
页数:6
相关论文
共 21 条
[1]   INVITRO SUSCEPTIBILITIES OF EDWARDSIELLA-TARDA TO 22 ANTIBIOTICS AND ANTIBIOTIC-BETA-LACTAMASE-INHIBITOR AGENTS [J].
CLARK, RB ;
LISTER, PD ;
JANDA, JM .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1991, 14 (02) :173-175
[2]   INFECTION WITH EDWARDSIELLA-TARDA RELATED TO A VASCULAR PROSTHESIS [J].
COUTLEE, F ;
SAINTJEAN, LA ;
PLANTE, R .
CLINICAL INFECTIOUS DISEASES, 1992, 14 (02) :621-622
[3]  
EWING W. H., 1965, INT BULL BACTERIOL NOMENCL TAXONOM, V15, P33
[4]   AN EPIZOOTIC OF EDWARDSIELLA-TARDA IN LARGEMOUTH BASS (MICROPTERUS, SALMOIDES) [J].
FRANCISFLOYD, R ;
REED, P ;
BOLON, B ;
ESTES, J ;
MCKINNEY, S .
JOURNAL OF WILDLIFE DISEASES, 1993, 29 (02) :334-336
[5]   Edwardsiella tarda bacteremia. A rare but fatal water- and foodborne infection: Review of the literature and clinical cases from a single centre [J].
Hirai, Yuji ;
Asahata-Tago, Sayaka ;
Ainoda, Yusuke ;
Fujita, Takahiro ;
Kikuchi, Ken .
CANADIAN JOURNAL OF INFECTIOUS DISEASES & MEDICAL MICROBIOLOGY, 2015, 26 (06) :313-318
[6]  
Iguchi M, 2012, J JPN ASS INFECT DIS, V86, P347
[7]  
Ikuko Teraguchi, 2009, J WAKAYAMA MED SOC, V60, P159
[8]  
Inoue Y, 2013, JPN J CARDIOVASC SUR, V42, P128
[9]  
JANDA JM, 1993, CLIN INFECT DIS, V17, P742, DOI 10.1093/clinids/17.4.742
[10]   HUMAN INFECTION WITH EDWARDSIELLA TARDA [J].
JORDAN, GW ;
HADLEY, WK .
ANNALS OF INTERNAL MEDICINE, 1969, 70 (02) :283-+