A fast progressive spectrum denoising combined with partial least squares algorithm and its application in online Fourier transform infrared quantitative analysis

被引:7
|
作者
Zhang, Genwei [1 ]
Peng, Silong [2 ,3 ]
Cao, Shuya [1 ]
Zhao, Jiang [1 ]
Xie, Qiong [2 ,3 ]
Han, Quanjie [2 ,3 ]
Wu, Yifan [2 ,3 ]
Huang, Qibin [1 ]
机构
[1] State Key Lab NBC Protect Civilian, Beijing 102205, Peoples R China
[2] Chinese Acad Sci, Inst Automat, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
Fourier transform infrared spectroscopy; Progressive spectrum denoising; Augmented Lagrange method; Partial least squares; Quantitative analysis; SPECTROSCOPY;
D O I
10.1016/j.aca.2019.04.055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fourier transform infrared (FTIR) spectroscopy is an important method in analytical chemistry. A material can be qualitatively and quantitatively analyzed from its FTIR spectrum. Spectrum denoising is commonly performed before online FTIR quantitative analysis. The average method requires a long time to collect spectra, which weakens real-time online analysis. The Savitzky-Golay smoothing method makes peaks smoother with the increase of window width, causing useful information to be lost. The sparse representation method is a common denoising method, that is used to reconstruct spectrum. However, for the randomness of noise, we can't achieve the sparse representation of noise. Traditional sparse representation algorithms only perform denoising once, and the noise can not be removed completely. FTIR spectrum denoising should therefore be performed in a progressive way. However, it is difficult to determine to what degree of denoising is required. Here, a fast progressive spectrum denoising combined with partial least squares method was developed for online FTIR quantitative analysis. Two real sample data sets were used to test the performance of the proposed method. The experimental results indicated that the progressive spectrum denoising method combined with the partial least squares method performed markedly better than other methods in terms of root mean squared error of prediction and coefficient of determination in the FTIR quantitative analysis. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 50 条
  • [21] Application of improved partial least squares method in near-infrared spectrum analysis for aviation kerosene
    Xing, Zhi-Na
    Wang, Ju-Xiang
    Shen, Gang
    Ye, Yong
    Liu, Jie
    Binggong Xuebao/Acta Armamentarii, 2010, 31 (08): : 1106 - 1109
  • [22] Use of Fourier transform infrared spectroscopy and partial least squares regression for the detection of adulteration of strawberry purees
    Holland, JK
    Kemsley, EK
    Wilson, RH
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1998, 76 (02) : 263 - 269
  • [23] Total Partial Least Square Regression and its application in infrared spectra quantitative analysis
    Mou, Yi
    Chen, Weizhen
    Liu, Jianguo
    MEASUREMENT, 2025, 247
  • [24] Artificial Neural Networks (ANNs) and Partial Least Squares (PLS) Regression in the Quantitative Analysis of Respirable Crystalline Silica by Fourier-Transform Infrared Spectroscopy (FTIR)
    Salehi, Mina
    Zare, Asma
    Taheri, Ali
    ANNALS OF WORK EXPOSURES AND HEALTH, 2021, 65 (03) : 346 - 357
  • [25] Analysis of sugars in Chinese rice wine by Fourier transform near-infrared spectroscopy with partial least-squares regression
    Niu, Xiaoying
    Shen, Fei
    Yu, Yanfei
    Yan, Zhanke
    Xu, Kai
    Yu, Haiyan
    Ying, Yibin
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (16) : 7271 - 7278
  • [26] Diffuse Reflection Infrared Fourier Transform Spectroscopy and Partial Least Squares Regression Analysis for Temperature Prediction of Irreversible Thermochromic Paints
    Kitagawa, Akiharu
    Welsh, Calum
    Mackilligin, Harry
    Licence, Peter
    APPLIED SPECTROSCOPY, 2022, 76 (05) : 538 - 540
  • [27] PARTIAL LEAST-SQUARES QUANTITATIVE-ANALYSIS OF INFRARED SPECTROSCOPIC DATA .1. ALGORITHM IMPLEMENTATION
    FULLER, MP
    RITTER, GL
    DRAPER, CS
    APPLIED SPECTROSCOPY, 1988, 42 (02) : 217 - 227
  • [28] Determination of the Degree of Degradation of Frying Rapeseed Oil Using Fourier-Transform Infrared Spectroscopy Combined with Partial Least-Squares Regression
    Chen, Jie Yu
    Zhang, Han
    Ma, Jinkui
    Tuchiya, Tomohiro
    Miao, Yelian
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 2015
  • [29] Kinetic Study of Alkoxysilane Hydrolysis under Acidic Conditions by Fourier Transform Near Infrared Spectroscopy Combined with Partial Least-Squares Model
    Zhai, Qianqian
    Zhou, Chuanjian
    Zhao, Shigui
    Peng, Cun
    Han, Yingchao
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (35) : 13598 - 13609
  • [30] PARTIAL LEAST-SQUARES QUANTITATIVE-ANALYSIS OF INFRARED SPECTROSCOPIC DATA .2. APPLICATION TO DETERGENT ANALYSIS
    FULLER, MP
    RITTER, GL
    DRAPER, CS
    APPLIED SPECTROSCOPY, 1988, 42 (02) : 228 - 235