Experimental Evaluation of a SiPM-Based Scintillation Detector for MR-Compatible SPECT Systems

被引:21
作者
Busca, Paolo [1 ,2 ]
Occhipinti, Michele [1 ,2 ]
Trigilio, Paolo [1 ,2 ]
Cozzi, Giulia [1 ,2 ]
Fiorini, Carlo [1 ,2 ]
Piemonte, Claudio [3 ]
Ferri, Alessandro [3 ]
Gola, Alberto [3 ]
Nagy, Kalman [4 ]
Buekki, Tamas [4 ]
Rieger, Jan [5 ]
机构
[1] Politecn Milan, Dipartimento Elettr Informaz & Bioingn, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
[3] FBK, I-38123 Trento, Italy
[4] Mediso Med Imaging Syst, H-1022 Budapest, Hungary
[5] MRI TOOLS GmbH, D-13125 Berlin, Germany
关键词
CsI:Tl; SiPM; SPECT/MRI; GAMMA; PERFORMANCE; MATRIX;
D O I
10.1109/TNS.2015.2481184
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the present work we briefly describe the architecture of a photo-detection module, designed in the framework of the INSERT (INtegrated SPECT/MRI for Enhanced Stratification in Radio-chemoTherapy) project, supported by the European Community. We focus on two main elements of the module: the SiPM photo-detector unit and the multi-channel ASIC. These two components have been investigated with dedicated and independent setups to assess preliminary performance of INSERT architecture. In details, we designed a 25.30 mm x 25.85 mm tile, comprising 9 pixels, each one with an 8 mm x 8mm active area. We developed an Anger camera to characterize the tile coupled to a CsI:Tl scintillator (6 mm thick). We measured an average spatial resolution (FWHM) of 2 mm in the central region of the Field of View and a 15.3% energy resolution using a Co-57 source (122 keV), when the tile is cooled down to 0 degrees C to reduce the impact of the dark count rate. Furthermore, we developed ANGUS, a 36-channels 0.35 mu m CMOS technology ASIC designed to cope with input capacitance up to 5 nF, typical of large area SiPM pixels. The spectroscopic capability of single readout channels were evaluated by coupling an 8 mm x 8 mm pixel with a cylindrical CsI:Tl scintillator (8 mm diameter, 10 mm thickness). Energy resolution at room temperature provided values between 13% and 13.5% (FWHM) at the 122 keV line for the nine pixels.
引用
收藏
页码:2122 / 2128
页数:7
相关论文
共 24 条
  • [1] SCINTILLATION CAMERA
    ANGER, HO
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (01) : 27 - 33
  • [2] Boschini L, 1999, IEEE NUCL SCI CONF R, P464, DOI 10.1109/NSSMIC.1999.842528
  • [3] Evaluation of a compact, high-resolution SPECT detector based on digital silicon photomultipliers
    Bouckaert, Carmen
    Vandenberghe, Stefaan
    Van Holen, Roel
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23) : 7521 - 7539
  • [4] Dual SPECT/MR imaging in small animal
    Breton, E.
    Choquet, P.
    Goetz, C.
    Kintz, J.
    Erbs, P.
    Rooke, R.
    Constantinesco, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) : 446 - 448
  • [5] MRC-SPECT: A sub-500 μm resolution MR-compatible SPECT system for simultaneous dual-modality study of small animals
    Cai, Liang
    Lai, Xiaochun
    Shen, Zengming
    Chen, Chin-Tu
    Meng, Ling-Jian
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 734 : 147 - 151
  • [6] Multimodality Imaging: Beyond PET/CT and SPECT/CT
    Cherry, Simon R.
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2009, 39 (05) : 348 - 353
  • [7] Scintillation Properties of LuAG:Ce, YAG:Ce and LYSO:Ce Crystals for Gamma-Ray Detection
    Chewpraditkul, W.
    Swiderski, L.
    Moszynski, M.
    Szczesniak, T.
    Syntfeld-Kazuch, A.
    Wanarak, C.
    Limsuwan, P.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (06) : 3800 - 3805
  • [8] BASIC: an 8-channel Front-end ASIC for Silicon Photomultiplier Detectors
    Corsi, F.
    Foresta, M.
    Marzocca, C.
    Matarrese, G.
    Del Guerra, A.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1082 - +
  • [9] David S., 2015, PHYS MEDICA, V15, pS1120
  • [10] A CMOS baseline holder (BLH) for readout ASICs
    De Geronimo, G
    O'Connor, P
    Grosholz, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 818 - 822