Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens-results of the EURALOC study

被引:24
|
作者
Domienik-Andrzejewska, Joanna [1 ]
Ciraj-Bjelac, Olivera [2 ]
Askounis, Panagiotis [3 ]
Covens, Peter [4 ]
Dragusin, Octavian [5 ]
Jacob, Sophie [6 ]
Farah, Jad [6 ]
Gianicolo, Emilio [7 ,8 ]
Padovani, Renato [9 ]
Teles, Pedro [10 ]
Widmark, Anders [11 ]
Struelens, Lara [12 ]
机构
[1] NIOM, 8 Sw Teresy Str, PL-91348 Lodz, Poland
[2] Univ Belgrade, Vinca Inst Nucl Sci VINCA, POB 522, Belgrade 11001, Serbia
[3] Greek Atom Energy Commiss, EEAE, Athens, Greece
[4] Vrije Univ Brussel, Brussels, Belgium
[5] FHL, Luxembourg, Luxembourg
[6] IRSN, BP17, F-92262 Fontenay Aux Roses, France
[7] Consiglio Nazl Ric Lecce, Ist Fisiol Clin, Lecce, Italy
[8] Johannes Gutenberg Univ Mainz, IMBEI, Mainz, Germany
[9] Abdus Salam Int Ctr Theoret Phys, Str Costiera 11, Trieste, Italy
[10] Inst Super Tecn Res & Dev, IST ID Assoc, Lisbon, Portugal
[11] NRPA, Oslo, Norway
[12] Belgian Nucl Res Ctr SCK CEN, Boeretang 200, BE-2400 Mol, Belgium
关键词
interventional cardiology; radiation protection; work practice of interventional cardiologists; fluoroscopy; access routes; RETROSPECTIVE ASSESSMENT; CORONARY-ANGIOGRAPHY; IONIZING-RADIATION; EXPOSURE; CATARACT; OPACITIES; ACCESS; RISK;
D O I
10.1088/1361-6498/aac64b
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper investigates over five decades of work practices in interventional cardiology, with an emphasis on radiation protection. The analysis is based on data from more than 400 cardiologists from various European countries recruited for a EURALOC study and collected in the period from 2014 to 2016. Information on the types of procedures performed and their annual mean number, fluoroscopy time, access site choice, x-ray units and radiation protection means used was collected using an occupational questionnaire. Based on the specific European data, changes in each parameter have been analysed over decades, while country-specific data analysis has allowed us to determine the differences in local practices. In particular, based on the collected data, the typical workload of a European cardiologist working in a haemodynamic room and an electrophysiology room was specified for various types of procedures. The results showed that when working in a haemodynamic room, a transparent ceiling-suspended lead shield or lead glasses are necessary in order to remain below the recommended eye lens dose limit of 20 mSv. Moreover, the analysis revealed that new, more complex cardiac procedures such as chronic total occlusion, valvuloplasty and pulmonary vein isolation for atrial fibrillation ablation might contribute substantially to annual doses, although they are relatively rarely performed. The results revealed that considerable progress has been made in the use of radiation protection tools. While their use in electrophysiology procedures is not generic, the situation in haemodynamic procedures is rather encouraging, as ceiling-suspended shields are used in 90% of cases, while the combination of ceiling shield and lead glasses is noted in more than 40% of the procedures. However, we find that still 7% of haemodynamic procedures are performed without any radiation protection tools.
引用
收藏
页码:934 / 950
页数:17
相关论文
共 4 条
  • [1] Eye lens dosimetry and the study on radiation cataract in interventional cardiologists
    Matsubara, Kosuke
    Lertsuwunseri, Vorarit
    Srimahachota, Suphot
    Krisanachinda, Anchali
    Tulvatana, Wasee
    Khambhiphant, Bharkbhum
    Sudchai, Waraporn
    Rehani, Madan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 232 - 235
  • [2] Characteristics of interventional cardiologists and their work practices for the study on radiation-induced lens opacities based on the methodology developed by ELDO-preliminary results
    Domienik, Joanna
    Gryglak, Szymon
    Jurewicz, Joanna
    JOURNAL OF RADIATION RESEARCH, 2016, 57 (04) : 431 - 437
  • [3] Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses
    Koukorava, C.
    Farah, J.
    Struelens, L.
    Clairand, I.
    Donadille, L.
    Vanhavere, F.
    Dimitriou, P.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (03) : 509 - 528
  • [4] Evaluation of factors influencing eye lens radiation dose while using radiation protection glasses in interventional radiology: A phantom study
    Imai, Shinya
    Yamahata, Asuka
    Gotanda, Tatsuhiro
    Akahane, Manabu
    Kawaji, Yasuyuki
    Akagawa, Takuya
    Yatake, Hidetoshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 184