Accuracy of Computer-Aided Techniques in Orthopaedic Surgery How Can It Be Defined, Measured Experimentally, and Analyzed from a Clinical Perspective?

被引:14
作者
Cartiaux, Olivier [1 ]
Jenny, Jean-Yves [1 ,2 ]
Joskowicz, Leo [1 ,3 ]
机构
[1] Catholic Univ Louvain, Inst Rech Expt & Clin, Comp Assisted & Robot Surg, Brussels, Belgium
[2] Hop Univ Strasbourg, Ctr Chirurg Orthoped & Main, Illkirch Graffenstaden, France
[3] Hebrew Univ Jerusalem, Rachel & Selim Benin Sch Comp Sci & Engn, Jerusalem, Israel
关键词
PEDICLE SCREW PLACEMENT; TOTAL KNEE ARTHROPLASTY; PATIENT-SPECIFIC INSTRUMENTS; BONE-TUMOR RESECTION; SURGICAL NAVIGATION; CUTTING ACCURACY; WIDE RESECTION; ALIGNMENT; IMPROVE; GUIDES;
D O I
10.2106/JBJS.15.01347
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Surgical accuracy is multifactorial. Therefore, it is crucial to consider all influencing factors when investigating the accuracy of a surgical procedure, such as the surgeon's experience, the assistive technologies that may be used by the surgeon, and the patient factors associated with the specific anatomical site. For in vitro preclinical investigations, accuracy should be linked to the concepts of trueness (e. g., distance from the surgical target) and precision (e. g., variability in relation to the surgical target) to gather preclinical, quantitative, objective data on the accuracy of completed surgical procedures that have been performed with assistive technologies. The clinical relevance of improvements in accuracy that have been observed experimentally may be evaluated by analyzing the impact on the risk of failure and by taking into account the level of tolerance in relation to the surgical target (e. g., the extent of the safety zone). The International Organization for Standardization (ISO) methodology enables preclinical testing of new assistive technologies to quantify improvements in accuracy and assess the benefits in terms of reducing the risk of failure and achieving surgical targets with tighter tolerances before the testing of clinical outcomes.
引用
收藏
页数:8
相关论文
共 65 条
[1]  
[Anonymous], 2008, E17708 ASTM INT
[2]  
[Anonymous], 2010, F255410 ASTM INT
[3]  
[Anonymous], 1994, 572511994 ISO
[4]  
[Anonymous], 2004, 11012004 ISO
[5]   Towards a standard in assessment of bone cutting for total knee replacement [J].
Barrera, O. A. ;
Haider, H. ;
Garvin, K. L. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H1) :63-74
[6]   Computer-assisted hip resurfacing surgery using the Acrobot® Navigation System [J].
Barrett, A. R. W. ;
Davies, B. L. ;
Gomes, M. P. S. F. ;
Harris, S. I. ;
Henckel, J. ;
Jakopec, M. ;
Kannan, V. ;
Rodriguez y Baena, F. M. ;
Cobb, J. P. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H7) :773-785
[7]   Navigation Did Not Improve the Precision of Minimally Invasive Knee Arthroplasty [J].
Bonutti, Peter M. ;
Dethmers, Daniel A. ;
McGrath, Mike S. ;
Ulrich, Slif D. ;
Mont, Michael A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (11) :2730-2735
[8]   Surgical inaccuracy of tumor resection and reconstruction within the pelvis - An experimental study [J].
Cartiaux, Olivier ;
Docquier, Pierre-Louis ;
Paul, Laurent ;
Francq, Bernard G. ;
Cornu, Olivier H. ;
Delloye, Christian ;
Raucent, Benoit ;
Dehez, Bruno ;
Banse, Xavier .
ACTA ORTHOPAEDICA, 2008, 79 (05) :695-702
[9]   Improved Accuracy with 3D Planning and Patient-Specific Instruments During Simulated Pelvic Bone Tumor Surgery [J].
Cartiaux, Olivier ;
Paul, Laurent ;
Francq, Bernard G. ;
Banse, Xavier ;
Docquier, Pierre-Louis .
ANNALS OF BIOMEDICAL ENGINEERING, 2014, 42 (01) :205-213
[10]   Computer-assisted planning and navigation improves cutting accuracy during simulated bone tumor surgery of the pelvis [J].
Cartiaux, Olivier ;
Banse, Xavier ;
Paul, Laurent ;
Francq, Bernard G. ;
Aubin, Carl-Eric ;
Docquier, Pierre-Louis .
COMPUTER AIDED SURGERY, 2013, 18 (1-2) :19-26