Realization of dysprosium doped lithium magnesium borate glass based TLD subjected to 1-100 Gy photon beam irradiations

被引:17
作者
Hashim, S. [1 ,2 ]
Omar, R. S. [1 ]
Ghoshal, S. K. [1 ]
机构
[1] Univ Teknol Malaysia, Fac Sci, Dept Phys, Johor Baharu 81310, Malaysia
[2] Univ Teknol Malaysia, ISI SIR, Ctr Sustainable Nanomat CSNano, Utm Skudai 81310, Johor, Malaysia
关键词
LMB glass; TLD; Dose response; Annealing; Fading; THERMOLUMINESCENCE PROPERTIES; SODIUM; LUMINESCENCE; TETRABORATE; DOSIMETERS;
D O I
10.1016/j.radphyschem.2019.05.016
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We explored the feasibility of using Dy2O3 doped lithium magnesium borate (LMB) glass based thermo-luminescence dosimeter (TLD) for high dose dosimetry in the range 1-100 Gy. Such glass system having composition (in mol%) of (70-z) B2O3-20Li(2)O-10MgO- zDy(2)O(3) (where 0.05 <= z <= 0.7 mol%) were prepared via melt-quenching method and subsequently characterized. Radioactive cobalt (Co-60) source was used for irradiations. The optimum dysprosium (Dy3+) content, annealing characteristics, optimum heating rate, sensitivity, thermal fading, reproducibility, TL glow curve and dose response linearity were determined. XRD pattern confirmed the amorphous nature of the synthesized glasses. DTA analysis authenticated a good glass forming ability and thermal stability of the studied glasses. EDX spectra verified the precise elemental traces in the sample ead to determine the effective atomic number (Z(eff)) of the studied samples. The optimum pre-annealing temperature and time was correspondingly discerned to be 200 degrees C and 60 min. Furthermore, glass doped with 0.1 mol% of Dy2O3 revealed optimal TLD reading through simple glow curve with minimal fading, high sensitivity and good reproducibility, good linearity with linear regression coefficient of 0.999 and 0.996 in the dose range of 1-10 Gy and 10-100 Gy, respectively. In short, the achieved TLD was established to be a good candidate for accurate radiation detection in photon beam in the 1-100 Gy range.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 37 条
  • [1] Effect of co-doping of lithium on the dosimetric properties of dysprosium-doped sodium borate glass system
    Alajerami, Y. S. M.
    Mhareb, M. H. A.
    Abushab, Khaled
    Ramadan, Khaled
    [J]. PHYSICA B-CONDENSED MATTER, 2019, 558 : 142 - 145
  • [2] Infrared luminescence and thermoluminescence of lithium borate glasses doped with Sm3+ ions
    Anjaiah, J.
    Laxmikanth, C.
    Veeraiah, N.
    Kistaiah, P.
    [J]. MATERIALS SCIENCE-POLAND, 2015, 33 (01): : 144 - 151
  • [3] Dosimetric characteristics of manganese doped lithium tetraborate - An improved TL phosphor
    Annalakshmi, O.
    Jose, M. T.
    Amarendra, G.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (08) : 669 - 675
  • [4] TL/OSL studies of Li2B4O7:Cu dosimetric phosphors
    Aydin, Talat
    Demirtas, Hayrunnisa
    Aydin, Samet
    [J]. RADIATION MEASUREMENTS, 2013, 58 : 24 - 32
  • [5] Advances in synthesis and characterization of LiMgBO3:Dy3+
    Bajaj, N. S.
    Omanwar, S. K.
    [J]. OPTIK, 2014, 125 (15): : 4077 - 4080
  • [6] Thermoluminescence and optically stimulated luminescence of PbO-H3BO3 and PbO-H3BO3-Al2O3 glasses
    Barrera, G. R.
    Souza, L. F.
    Novais, A. L. F.
    Caldas, L. V. E.
    Abreu, C. M.
    Machado, R.
    Sussuchi, E. M.
    Souza, D. N.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 150 - 157
  • [7] Chen R., 1997, THEORY THERMOLUMINES, DOI DOI 10.1142/9789812830890_0007
  • [8] Comparison of thermoluminescent readers exploring different reading protocols for LiF:Mg,Cu,P (MCP-N) detectors
    De Saint-Hubert, Marijke
    Knezevic, Zeljka
    Nascimento, Luana De Freitas
    Parisi, Alessio
    Van Hoey, Olivier
    Vanhavere, Filip
    [J]. RADIATION MEASUREMENTS, 2019, 121 : 61 - 68
  • [9] Thermoluminescence characteristics of Li2B4O7 single crystal dosimeters doped with Mn
    Ekdal, E.
    Karali, T.
    Kelemen, A.
    Ignatovych, M.
    Holovey, V.
    Harmansah, C.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 96 : 201 - 204
  • [10] Organ doses evaluation for chest computed tomography procedures with TL dosimeters: Comparison with Monte Carlo simulations
    Giansante, Louise
    Martins, Juliana C.
    Nersissian, Denise Y.
    Kiers, Karen C.
    Kay, Fernando U.
    Sawamura, Marcia V. Y.
    Lee, Choonsik
    Gebrim, Eloisa M. M. S.
    Costa, Paulo R.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 308 - 320