Validity of correction factors applied to auditory steady-state responses(ASSRs) in normal hearing adults in chartr EP system

被引:3
作者
Ghasemahmad, Zahra [1 ]
Farahani, Saeid [1 ]
机构
[1] Univ Tehran Med Sci, Sch Rehabil, Dept Audiol, Enghelab Ave,POB 11365-1683, Tehran 11498, Iran
关键词
Auditory steady-state response (ASSR); Pure tone audiometry (PTA); Correction factor; Difference score; Normal hearing adults; BRAIN-STEM RESPONSE; THRESHOLD ESTIMATION; ASSR; MODULATION; POTENTIALS; STIMULUS; HZ;
D O I
10.1007/s00405-019-05451-3
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
ObjectivesEven though many patients undergoing auditory steady-state response (ASSR) testing have some degree of hearing loss, some have normal hearing and ASSR often overestimates the behavioral thresholds in this group. In most commercial ASSR systems such as Chartr EP, a default correction factor is applied to compensate for this difference. Little is known, however, as how the correction factor compensates for the difference between ASSR and pure tone audiometry (PTA) thresholds as a function of carrier or modulation frequency (MF) in a commercial ASSR system. Our goal is to evaluate this relationship.MethodsTwenty-four normal hearing adults were examined for both PTA and ASSR (Chartr EP system, GN Otometrics). ASSR thresholds were obtained at three MFs (20, 40, and 80Hz). The difference scores were obtained by subtracting PTA from ASSR thresholds at each frequency for each subject. The corrected ASSR thresholds, then, were compared with the PTA thresholds across MFs and carrier frequencies.ResultsThe default correction factors in the ASSR equipment differed significantly from the difference scores at all MFs and carrier frequencies (n=24, p<0.005). The correlation between corrected ASSR and PTA thresholds at most MFs and carrier frequencies were medium to poor.ConclusionsAt most MFs and carrier frequencies, the default correction factors defined by the manufacturer do not compensate for the difference between ASSR and PTA thresholds in normal hearing adults. The use of the default correction factors in Chartr EP system for the normal hearing adults needs special considerations.
引用
收藏
页码:2171 / 2180
页数:10
相关论文
共 31 条
[1]   Hearing threshold estimation by auditory steady state responses (ASSR) in children [J].
Aimoni, C. ;
Crema, L. ;
Savini, S. ;
Negossi, L. ;
Rosignoli, M. ;
Sacchetto, L. ;
Bianchini, C. ;
Ciorba, A. .
ACTA OTORHINOLARYNGOLOGICA ITALICA, 2018, 38 (04) :361-368
[2]   PREFERRED METHOD FOR CLINICAL DETERMINATION OF PURE-TONE THRESHOLDS [J].
CARHART, R ;
JERGER, JF .
JOURNAL OF SPEECH AND HEARING DISORDERS, 1959, 24 (04) :330-345
[3]  
Cone-Wesson Barbara, 2002, J Am Acad Audiol, V13, P173
[4]  
Dimitrijevic Andrew, 2002, J Am Acad Audiol, V13, P205
[5]  
Dobie RA, 2004, HEARING LOSS DETERMI
[6]  
Hall J W 3rd, 1997, Adv Otorhinolaryngol, V53, P21
[7]   Hearing threshold prediction with Auditory Steady State Responses and estimation of correction functions to compensate for differences with behavioral data, in adult subjects. Part 1: Audera and CHARTR EP devices [J].
Hatzopoulos, Stavros ;
Petruccelli, Joseph ;
Sliwa, Lech ;
Jedrzejczak, Wieslaw W. ;
Kochanek, Krzysztof ;
Skarzynski, Henryk .
MEDICAL SCIENCE MONITOR, 2012, 18 (07) :MT47-MT53
[8]  
Hatzopoulos S, 2010, MED SCI MONITOR, V16, pCR21
[9]   Auditory steady-state response thresholds of adults with sensorineural hearing impairments [J].
Herdman, AT ;
Stapells, DR .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2003, 42 (05) :237-248
[10]   Thresholds determined using the monotic and dichotic multiple auditory steady-state response technique in normal-hearing subjects [J].
Herdman, AT ;
Stapells, DR .
SCANDINAVIAN AUDIOLOGY, 2001, 30 (01) :41-49