Influence of bone quality on the strength of internal and external fixation of tibial plateau fractures

被引:31
|
作者
Ali, Ahmad M.
Saleh, Michael
Eastell, Richard
Wigderowitz, Carlos A.
Rigby, Alan S.
Yang, Lang [1 ]
机构
[1] Univ Sheffield, Div Clin Sci N, Acad Unit Bone Metab, Sheffield S5 7AU, S Yorkshire, England
[2] Univ Hull, Kingston Upon Hull HU6 7RX, N Humberside, England
[3] Univ Dundee, Ninewells Hosp, Dept Orthopaed & Trauma Surg, Dundee DD1 9SY, Scotland
[4] Univ Sheffield, Div Clin Sci N, Orthopaed & Traumat Surg Res Grp, Sheffield S5 7AU, S Yorkshire, England
[5] Oldchurch Hosp, Dept Orthopaed & Traumatol, Romford RM7 0BE, Essex, England
关键词
tibial plateau fracture; internal fixation; external fixation; bone quality; mechanical strength;
D O I
10.1002/jor.20270
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied the influence of different parameters of bone quality on the fixation strength of bicondylar tibial plateau fractures and examined the relationship between these parameters. Bone quality was measured in the plateau of 16 cadaveric tibias using three modalities: dual-energy X-ray absorptiometry (DXA), peripheral quantitative computer tomography (pQCT), and spectral analysis of digitized radiographs (SADR). The tibias were divided into two groups by the median bone mineral density (BMD) and randomized to receive either dual plating or external fixator for the stabilization of a standardized bicondylar tibial fracture. The fixed fractures were subjected to axial compression until failure. DXA BMD correlated most significantly with the failure load (r >= 0. 79, p < 0.001), followed by the pQCT parameters of cancellous bone (0.52 > r > 0.73, p < 0.01). Similar strong correlations were also evident in both fixation methods. For parameters derived from SADR, only those including both longitudinal and transverse trabecular orientations had modest correlation with the fixation strength (0.53 > r > 0.71, p < 0.01). The failure loads of the two fixation techniques were not significantly different (mean +/- SD = 3522 +/- 1386 N and 3710 +/- 1356 N, respectively, p = 0.78). However, BMD in the dual-plating group influenced the failure load significantly (p = 0.03), whereas in the external fixation group this was less evident (P = 0.100). The majority of bone quality parameters that correlated with fixation strength were also strongly correlated with each other, particularly the BMDs measured by DXA and pQCT. This is the first study that relates fixation strength of bicondylar tibial plateau fractures to bone quality assessed at the same anatomical site. BMD around the fracture site had the best correlation with the failure load regardless of the fixation technique. The two fixation methods tested performed equally well, and the choice between them depends on the soft tissue condition and surgeon preference. (c) 2006 Orthopaedic Research Society.
引用
收藏
页码:2080 / 2086
页数:7
相关论文
共 50 条
  • [41] Surgical site infection after open reduction and internal fixation of tibial plateau fractures
    Lin S.
    Mauffrey C.
    Hammerberg E.M.
    Stahel P.F.
    Hak D.J.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (5) : 797 - 803
  • [42] External fixation of segmental tibial shaft fractures
    Milenkovic, Sasa
    Mitkovic, Milan
    Mitkovic, Milorad
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2020, 46 (05) : 1123 - 1127
  • [43] External fixation of segmental tibial shaft fractures
    Sasa Milenkovic
    Milan Mitkovic
    Milorad Mitkovic
    European Journal of Trauma and Emergency Surgery, 2020, 46 : 1123 - 1127
  • [44] Compression plating of tibial fractures following primary external fixation
    C. H. Siebert
    K. -P. Lehrbaß-Sökeland
    F. Rinke
    M. Hansis
    Archives of Orthopaedic and Trauma Surgery, 1997, 116 : 390 - 395
  • [45] The application of a three-column internal fixation system with anatomical locking plates on comminuted fractures of the tibial plateau
    Lin, Wang
    Su, Yu
    Lin, ChenShou
    Guo, WeiZhong
    Wu, JinQing
    Wang, YingYing
    Zhang, ShenShen
    Liu, ShouKun
    Liu, Wen
    Chen, Lian
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (07) : 1509 - 1514
  • [46] The application of a three-column internal fixation system with anatomical locking plates on comminuted fractures of the tibial plateau
    Wang Lin
    Yu Su
    ChenShou Lin
    WeiZhong Guo
    JinQing Wu
    YingYing Wang
    ShenShen Zhang
    ShouKun Liu
    Wen Liu
    Lian Chen
    International Orthopaedics, 2016, 40 : 1509 - 1514
  • [47] Application of hybrid external fixation by the "joystick method" in bicondylar tibial plateau fractures: Technical note
    Kuyucu, Ersin
    Kara, Adnan
    Say, Ferhat
    Erdil, Mehmet
    Bulbul, Murat
    Gulenc, Baris
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2018, 24 (03): : 263 - 267
  • [48] Treatment of open and comminuted mid-distal tibial fractures by bilateral external fixation combined with limited-internal fixation
    Liang, Hongsuo
    Li, Lin
    Yang, Jingye
    Du, Yongjun
    Peng, Wuxun
    ACTA ORTHOPAEDICA BELGICA, 2021, 87 (04): : 745 - 750
  • [49] Fixation of tibial plateau fractures with synthetic bone graft versus natural bone graft: a comparison study
    J. C. Y. Ong
    M. T. Kennedy
    A. Mitra
    J. A. Harty
    Irish Journal of Medical Science, 2012, 181 : 247 - 252
  • [50] Are Infection Rates Increased After Sterilization of the External Fixator During Staged Internal Fixation of High-Energy Tibial Plateau Fractures?
    Moon, Tyler James
    Haase, Lucas
    Haase, Douglas
    Ochenjele, George
    Wise, Brent
    Napora, Joshua
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2022, 36 (10) : 530 - 534