Influence of bone quality on the strength of internal and external fixation of tibial plateau fractures

被引:31
|
作者
Ali, Ahmad M.
Saleh, Michael
Eastell, Richard
Wigderowitz, Carlos A.
Rigby, Alan S.
Yang, Lang [1 ]
机构
[1] Univ Sheffield, Div Clin Sci N, Acad Unit Bone Metab, Sheffield S5 7AU, S Yorkshire, England
[2] Univ Hull, Kingston Upon Hull HU6 7RX, N Humberside, England
[3] Univ Dundee, Ninewells Hosp, Dept Orthopaed & Trauma Surg, Dundee DD1 9SY, Scotland
[4] Univ Sheffield, Div Clin Sci N, Orthopaed & Traumat Surg Res Grp, Sheffield S5 7AU, S Yorkshire, England
[5] Oldchurch Hosp, Dept Orthopaed & Traumatol, Romford RM7 0BE, Essex, England
关键词
tibial plateau fracture; internal fixation; external fixation; bone quality; mechanical strength;
D O I
10.1002/jor.20270
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied the influence of different parameters of bone quality on the fixation strength of bicondylar tibial plateau fractures and examined the relationship between these parameters. Bone quality was measured in the plateau of 16 cadaveric tibias using three modalities: dual-energy X-ray absorptiometry (DXA), peripheral quantitative computer tomography (pQCT), and spectral analysis of digitized radiographs (SADR). The tibias were divided into two groups by the median bone mineral density (BMD) and randomized to receive either dual plating or external fixator for the stabilization of a standardized bicondylar tibial fracture. The fixed fractures were subjected to axial compression until failure. DXA BMD correlated most significantly with the failure load (r >= 0. 79, p < 0.001), followed by the pQCT parameters of cancellous bone (0.52 > r > 0.73, p < 0.01). Similar strong correlations were also evident in both fixation methods. For parameters derived from SADR, only those including both longitudinal and transverse trabecular orientations had modest correlation with the fixation strength (0.53 > r > 0.71, p < 0.01). The failure loads of the two fixation techniques were not significantly different (mean +/- SD = 3522 +/- 1386 N and 3710 +/- 1356 N, respectively, p = 0.78). However, BMD in the dual-plating group influenced the failure load significantly (p = 0.03), whereas in the external fixation group this was less evident (P = 0.100). The majority of bone quality parameters that correlated with fixation strength were also strongly correlated with each other, particularly the BMDs measured by DXA and pQCT. This is the first study that relates fixation strength of bicondylar tibial plateau fractures to bone quality assessed at the same anatomical site. BMD around the fracture site had the best correlation with the failure load regardless of the fixation technique. The two fixation methods tested performed equally well, and the choice between them depends on the soft tissue condition and surgeon preference. (c) 2006 Orthopaedic Research Society.
引用
收藏
页码:2080 / 2086
页数:7
相关论文
共 50 条
  • [31] Do clinical outcomes correlate with bone density after open reduction and internal fixation of tibial plateau fractures
    Gausden, Elizabeth
    Garner, Matthew R.
    Fabricant, Peter D.
    Warner, Stephen J.
    Shaffer, Andre D.
    Lorich, Dean G.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (06) : 755 - 760
  • [32] The combined internal and external fixation surgery is effective and safe in treating posterior lateral tibial plateau fractures: An observational study
    Guo, Yuechao
    An, Wen
    Ma, Jialiang
    Wang, Zhe
    Zhang, Yujian
    MEDICINE, 2024, 103 (36)
  • [33] Staged treatment of bicondylar tibial plateau fractures: influence of frame configuration and quality of reduction on outcomes
    Oleo-Taltavull, Rafael
    Corro, Sebastian
    Tomas-Hernandez, Jordi
    Teixidor-Serra, Jordi
    Selga-Marsa, Jordi
    Porcel-Vazquez, Juan Antonio
    Piedra-Calle, Carlos Alberto
    Garcia-Sanchez, Yaiza
    Guerra-Farfan, Ernesto Melchor
    Andres-Peiro, Jose Vicente
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2024, 50 (03) : 1033 - 1041
  • [34] Surgical fixation methods for tibial plateau fractures
    Smith, Toby O.
    Casey, Laura
    McNamara, Iain R.
    Hing, Caroline B.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2024, (08):
  • [35] Computed tomography of bicondylar tibial plateau fractures after distraction with a bridging external fixation
    Ryu, Seung Min
    Park, Jae Woo
    Moon, Jeong Jae
    Lim, Seung Wan
    Kwon, Moon Soo
    Shon, Oog Jin
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (10) : 2451 - 2458
  • [36] Computed tomography of bicondylar tibial plateau fractures after distraction with a bridging external fixation
    Seung Min Ryu
    Jae Woo Park
    Jeong Jae Moon
    Seung Wan Lim
    Moon Soo Kwon
    Oog Jin Shon
    International Orthopaedics, 2018, 42 : 2451 - 2458
  • [37] Does maintaining external fixators during definitive fixation of bicondylar tibial plateau fractures influence fracture alignment and deep infection rates?
    Mickley, John
    Philips, William
    Colosimo, Sara
    Kurtic, Dinela
    Gitlin, Adam
    Young, Porter
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2025, 56 (03):
  • [38] Early external fixation of tibial plateau fractures is associated with an increased risk of compartment syndrome
    Wier, Julian
    Duong, Andrew M.
    Gary, Joshua L.
    Patterson, Joseph T.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (11):
  • [39] Bicondylar tibial plateau fractures treated with fine-wire circular external fixation
    Ferreira, N.
    Marais, L. C.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2014, 9 (01): : 25 - 32
  • [40] Different internal fixation methods for Hoffa-like fractures of the tibial plateau: a finite element analysis
    Xue, Hang
    Deng, Junrong
    Zhang, Zhenhe
    Knoedler, Samuel
    Panayi, Adriana C.
    Knoedler, Leonard
    Mi, Bobin
    Liu, Mengfei
    Dai, Guandong
    Liu, Guohui
    FRONTIERS IN MEDICINE, 2023, 10