Influence of bone quality on the strength of internal and external fixation of tibial plateau fractures

被引:32
作者
Ali, Ahmad M.
Saleh, Michael
Eastell, Richard
Wigderowitz, Carlos A.
Rigby, Alan S.
Yang, Lang [1 ]
机构
[1] Univ Sheffield, Div Clin Sci N, Acad Unit Bone Metab, Sheffield S5 7AU, S Yorkshire, England
[2] Univ Hull, Kingston Upon Hull HU6 7RX, N Humberside, England
[3] Univ Dundee, Ninewells Hosp, Dept Orthopaed & Trauma Surg, Dundee DD1 9SY, Scotland
[4] Univ Sheffield, Div Clin Sci N, Orthopaed & Traumat Surg Res Grp, Sheffield S5 7AU, S Yorkshire, England
[5] Oldchurch Hosp, Dept Orthopaed & Traumatol, Romford RM7 0BE, Essex, England
关键词
tibial plateau fracture; internal fixation; external fixation; bone quality; mechanical strength;
D O I
10.1002/jor.20270
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied the influence of different parameters of bone quality on the fixation strength of bicondylar tibial plateau fractures and examined the relationship between these parameters. Bone quality was measured in the plateau of 16 cadaveric tibias using three modalities: dual-energy X-ray absorptiometry (DXA), peripheral quantitative computer tomography (pQCT), and spectral analysis of digitized radiographs (SADR). The tibias were divided into two groups by the median bone mineral density (BMD) and randomized to receive either dual plating or external fixator for the stabilization of a standardized bicondylar tibial fracture. The fixed fractures were subjected to axial compression until failure. DXA BMD correlated most significantly with the failure load (r >= 0. 79, p < 0.001), followed by the pQCT parameters of cancellous bone (0.52 > r > 0.73, p < 0.01). Similar strong correlations were also evident in both fixation methods. For parameters derived from SADR, only those including both longitudinal and transverse trabecular orientations had modest correlation with the fixation strength (0.53 > r > 0.71, p < 0.01). The failure loads of the two fixation techniques were not significantly different (mean +/- SD = 3522 +/- 1386 N and 3710 +/- 1356 N, respectively, p = 0.78). However, BMD in the dual-plating group influenced the failure load significantly (p = 0.03), whereas in the external fixation group this was less evident (P = 0.100). The majority of bone quality parameters that correlated with fixation strength were also strongly correlated with each other, particularly the BMDs measured by DXA and pQCT. This is the first study that relates fixation strength of bicondylar tibial plateau fractures to bone quality assessed at the same anatomical site. BMD around the fracture site had the best correlation with the failure load regardless of the fixation technique. The two fixation methods tested performed equally well, and the choice between them depends on the soft tissue condition and surgeon preference. (c) 2006 Orthopaedic Research Society.
引用
收藏
页码:2080 / 2086
页数:7
相关论文
共 30 条
[1]  
ALI A, J BIOMECH, V39, P1355
[2]   The strength of different fixation techniques for bicondylar tibial plateau fractures - a biomechanical study [J].
Ali, AM ;
Saleh, M ;
Bolongaro, S ;
Yang, L .
CLINICAL BIOMECHANICS, 2003, 18 (09) :864-870
[3]   Outcome of complex fractures of the tibial plateau treated with a beam-loading ring fixation system [J].
Ali, AM ;
Burton, M ;
Hashmi, M ;
Saleh, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (05) :691-699
[4]   Treatment of displaced bicondylar tibial plateau fractures (OTA-41C2&3) in patients older than 60 years of age [J].
Ali, AM ;
Burton, T ;
Hashmi, T ;
Saleh, T .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (05) :346-352
[5]   Failure of fixation of tibial plateau fractures [J].
Ali, AM ;
El-Shafie, M ;
Willett, KM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) :323-329
[6]  
Altman D., 2000, STAT CONFIDENCE
[7]  
Augat P, 1996, J BONE MINER RES, V11, P1356
[8]   pQCT measurement of bone parameters in young children - Validation of technique [J].
Binkley, TL ;
Specker, BL .
JOURNAL OF CLINICAL DENSITOMETRY, 2000, 3 (01) :9-14
[9]   COMPUTERIZED RADIOGRAPHIC ANALYSIS OF OSTEOPOROSIS - PRELIMINARY EVALUATION [J].
CALIGIURI, P ;
GIGER, ML ;
FAVUS, MJ ;
JIA, H ;
DOI, K ;
DIXON, LB .
RADIOLOGY, 1993, 186 (02) :471-474
[10]  
CARTER DR, 1992, J BONE MINER RES, V7, P137