Radon activity concentration -: a Euromet and BIPM supplementary comparison

被引:14
作者
Roettger, A.
Honig, A.
Schmidt, V.
Buchroeder, H.
Rox, A.
Butterweck, G.
Schuler, Ch.
Maringer, F. J.
Jachs, P.
Edelmaier, R.
Michielsen, N.
Howarth, C. B.
Miles, J. C. H.
Vargas, A.
Ortega, X.
Burian, I.
Turtiainen, T.
Hagberg, N.
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[2] Bundesamt Strahlenschutz, D-10318 Berlin, Germany
[3] Mat Prufungsamt Nordrhein Westfalen, D-44287 Dortmund, Germany
[4] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[5] ARC Seibersdorf Res GmbH, A-1030 Vienna, Austria
[6] Bundesamt Eich & Vermessungswesen, A-1160 Vienna, Austria
[7] CEA Saclay, IRSN, F-91192 Gif Sur Yvette, France
[8] HPA, Radiol Protect Div, Didcot OX11 0RQ, Oxon, England
[9] Univ Politecn Cataluna, INTEC, E-08028 Barcelona, Spain
[10] Statni Ustav Jaderne Chem & Biol Ochrany, CZ-26231 Milin, Czech Republic
[11] STUK, FIN-00881 Helsinki, Finland
[12] SSI, S-17116 Stockholm, Sweden
关键词
radon activity concentrations; comparison;
D O I
10.1016/j.apradiso.2006.02.086
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
For the first time, a comparison of radon activity concentration in air has been performed within the scope of Euromet. In the project 657, 'Comparison of calibration facilities for the radon activity concentration,' 12 participants from 9 countries compared different radon reference atmospheres at 1, 3 and 10 kBq m(-3) via a transfer standard. The comparison was listed as BIPM supplementary comparison EUROMET.RI(II)-S1. The results of most participants are correlated due to common traceability to one single radon gas standard producer. This makes a careful correlation analysis necessary to achieve an appropriate comparison reference value. The results of the comparison as well as the complex analysis of the correlated set of data is presented and discussed. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1102 / 1107
页数:6
相关论文
共 8 条
[1]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[2]  
Butterweck G, 2002, RADIAT PROT DOSIM, V98, P219, DOI 10.1093/oxfordjournals.rpd.a006712
[3]   AN INTERCOMPARISON OF RN-222 MEASUREMENT SYSTEMS IN EUROPEAN LABORATORIES [J].
DEAN, JCJ ;
BURKE, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2) :264-270
[4]  
Richter Dieter, 2003, DATA ANAL KEY COMP
[5]  
ROTTGER A, 2005, RADIOACTIVITY ENV NA
[6]  
ROTTGER A, 2005, METROLOGIA, P42
[7]   New developments of the GUM and Monte Carlo techniques [J].
Sibert, BRL ;
Sommer, KD .
TECHNISCHES MESSEN, 2004, 71 (02) :67-80
[8]   Practical determination of the measurement uncertainty under GUM [J].
Sommer, KD ;
Siebert, BRL .
TECHNISCHES MESSEN, 2004, 71 (02) :52-66