Simultaneous underway analysis of nitrate and nitrite in estuarine and coastal waters using an automated integrated syringe-pump-based environmental-water analyzer

被引:31
|
作者
Fang, Tengyue [1 ]
Li, Peicong [1 ]
Lin, Kunning [1 ]
Chen, Nengwang [1 ]
Jiang, Yiyong [1 ]
Chen, Jixin [1 ]
Yuan, Dongxing [1 ]
Ma, Jian [1 ]
机构
[1] Xiamen Univ, State Key Lab Marine Environm Sci, Fujian Prov Key Lab Coastal Ecol & Environm Studi, Coll Environm & Ecol, Xiamen 361102, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Nitrate; Nitrite; Flow analysis; Estuarine and coastal water; Underway analysis; Spectrophotometry; FLOW-INJECTION ANALYSIS; REDUCTION; PHOSPHATE; NUTRIENTS; SEAWATER; NITROGEN; SYSTEM; AMMONIUM; SENSOR;
D O I
10.1016/j.aca.2019.05.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Methods for determining nitrate and nitrite have been comprehensively developed. However, there are few studies of simultaneous shipboard high-frequency monitoring of these two nutrients in estuarine and coastal area. In this study, a multipurpose integrated syringe-pump-based environmental-water analyzer (iSEA) was combined with an on-line filtration system for underway analysis of nitrate and nitrite in saline samples. Vanadium chloride was used instead of a toxic cadmium column to reduce nitrate to nitrite, which was measured on the basis of the classic Griess reaction. This fully automated analyzer had a limit of detection of 0.02 mmol L-1 for nitrite and 0.14 mmol L-1 for nitrate. The sample throughput was 12 h(-1) for simultaneous measurement of nitrite and nitrate. With automated dilution, the calibration curve for nitrate was linear up to a concentration of 400 mmol L-1 (R-2 > 0.999). The relative standard deviation of 24-h measurement (n = 288) of nitrite is 0.92% and that of nitrate is 1.4%. Both the reference solutions and samples of different salinities (range of 0-35) were measured (n = 85). According to the statistical t-test (P = 0.95), the results were insignificantly different from the results obtained using the reference method. After several cruise tests, the analyzer showed excellent spatial resolution for underway analysis of nitrite and nitrate in estuarine and coastal waters. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:100 / 109
页数:10
相关论文
共 5 条
  • [1] High-frequency underway analysis of ammonium in coastal waters using an integrated syringe-pump-based environmental-water analyzer (iSEA)
    Li, Peicong
    Deng, Yao
    Shu, Huilin
    Lin, Kunning
    Chen, Nengwang
    Jiang, Yiong
    Chen, Jixin
    Yuan, Dongxing
    Ma, Jian
    TALANTA, 2019, 195 : 638 - 646
  • [2] Development of an Integrated Syringe-Pump-Based Environmental-Water Analyzer (iSEA) and Application of It for Fully Automated Real-Time Determination of Ammonium in Fresh Water
    Ma, Jian
    Li, Peicong
    Chen, Zhaoying
    Lin, Kunning
    Chen, Nengwang
    Jiang, Yiyong
    Chen, Jixin
    Huang, Bangqin
    Yuan, Dongxing
    ANALYTICAL CHEMISTRY, 2018, 90 (11) : 6431 - 6435
  • [3] Real-time underway measurement of ammonium in coastal and estuarine waters using an automated flow analyzer with hollow fiber membrane contactor
    Li, Peng
    Li, Songtao
    Yuan, Dongxing
    Lin, Kunde
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 880
  • [4] Automated syringe-pump-based flow-batch analysis for spectrophotometric determination of trace hexavalent chromium in water samples
    Zhu, Xiangyu
    Deng, Yao
    Li, Peicong
    Yuan, Dongxing
    Ma, Jian
    MICROCHEMICAL JOURNAL, 2019, 145 : 1135 - 1142
  • [5] An automatic reserve flow injection method using vanadium (III) reduction for simultaneous determination of nitrite and nitrate in estuarine and coastal waters
    Lin, Kunning
    Li, Peicong
    Ma, Jian
    Yuan, Dongxing
    TALANTA, 2019, 195 : 613 - 618