Influence of direct-connected inverter with one power switch open circuit fault on electromagnetic field and temperature field of permanent magnet synchronous motor

被引:16
|
作者
Li, Weili [1 ]
Li, Lin [1 ]
Gao, Hanying [2 ]
Li, Dong [1 ,3 ]
Zhang, Xiaochen [1 ]
Fan, Yu [1 ]
机构
[1] Beijing Jiaotong Univ, Sch Elect Engn, Beijing, Peoples R China
[2] Harbin Univ Sci & Technol, Coll Elect & Elect Engn, Harbin, Heilongjiang, Peoples R China
[3] Beijing Jiaotong Univ, Sch Elect & Informat Engn, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
VARIABLE-SPEED DRIVES; TOLERANT CONTROL; DIAGNOSIS; INDUCTION; MACHINE; LOSSES;
D O I
10.1049/iet-epa.2017.0631
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For permanent magnetic motors, the faults in inverter may cause serious mechanical vibration, winding overheating, and thermal demagnetisation for the magnets. Thus, this study addresses the problem of the electromagnetic field and temperature distributions for permanent magnet synchronous motor (PMSM) under open circuit fault (OCF) in the upper switch of one phase. Firstly, taking a 12.5kW 2000 r/min PMSM as an example, the 2D transient electromagnetic field-circuit coupling calculation model is established. Then the flowing paths of the three-phase currents in inverter are analysed before and after the OCF in the upper switch of one phase. Next, by using the finite-element method, the current harmonics, the electromagnetic torque, the rotating speed, and the losses in PMSM are investigated. Simultaneously, direct current component and torque pulsation are also derived. Based on the 3D temperature field, the temperature distributions in different parts of PMSM also are comparatively studied before and after this fault. Moreover, the temperature of permanent magnets, which is the part most seriously affected by the temperature, are further analysed. Finally, calculation and experimental tests prove the accuracy of the theoretical analysis. The obtained conclusions may provide some references for the limit operation and effective diagnosis for inverter faults.
引用
收藏
页码:815 / 825
页数:11
相关论文
共 32 条
  • [31] Improved control strategy of dual star permanent magnet synchronous generator based tidal turbine system using sensorless field oriented control and direct power control techniques
    Amirouche, Elyazid
    Iffouzar, Koussaila
    Houari, Azeddine
    Ghedamsi, Kaci
    Aouzellag, Djamal
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021,
  • [32] 3-D Analytical Model and Direct Measurement Method of Ultra-Thin Open-Circuit Air-Gap Field of Interior Permanent Magnet Synchronous Motor With Multi-Segmented Skew Poles and Multi-Layered Flat Wire Windings for Electric Vehicle
    Ma, Conggan
    An, Yuansheng
    Zhao, Huichao
    Guo, Shoulun
    Yin, Xiangrui
    Lu, Haifeng
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2020, 35 (03) : 1316 - 1326