Influence of direct-connected inverter with one power switch open circuit fault on electromagnetic field and temperature field of permanent magnet synchronous motor

被引:17
作者
Li, Weili [1 ]
Li, Lin [1 ]
Gao, Hanying [2 ]
Li, Dong [1 ,3 ]
Zhang, Xiaochen [1 ]
Fan, Yu [1 ]
机构
[1] Beijing Jiaotong Univ, Sch Elect Engn, Beijing, Peoples R China
[2] Harbin Univ Sci & Technol, Coll Elect & Elect Engn, Harbin, Heilongjiang, Peoples R China
[3] Beijing Jiaotong Univ, Sch Elect & Informat Engn, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
VARIABLE-SPEED DRIVES; TOLERANT CONTROL; DIAGNOSIS; INDUCTION; MACHINE; LOSSES;
D O I
10.1049/iet-epa.2017.0631
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For permanent magnetic motors, the faults in inverter may cause serious mechanical vibration, winding overheating, and thermal demagnetisation for the magnets. Thus, this study addresses the problem of the electromagnetic field and temperature distributions for permanent magnet synchronous motor (PMSM) under open circuit fault (OCF) in the upper switch of one phase. Firstly, taking a 12.5kW 2000 r/min PMSM as an example, the 2D transient electromagnetic field-circuit coupling calculation model is established. Then the flowing paths of the three-phase currents in inverter are analysed before and after the OCF in the upper switch of one phase. Next, by using the finite-element method, the current harmonics, the electromagnetic torque, the rotating speed, and the losses in PMSM are investigated. Simultaneously, direct current component and torque pulsation are also derived. Based on the 3D temperature field, the temperature distributions in different parts of PMSM also are comparatively studied before and after this fault. Moreover, the temperature of permanent magnets, which is the part most seriously affected by the temperature, are further analysed. Finally, calculation and experimental tests prove the accuracy of the theoretical analysis. The obtained conclusions may provide some references for the limit operation and effective diagnosis for inverter faults.
引用
收藏
页码:815 / 825
页数:11
相关论文
共 25 条
[1]   Fault-tolerant control in variable speed drives: a survey [J].
Campos-Delgado, D. U. ;
Espinoza-Trejo, D. R. ;
Palacios, E. .
IET ELECTRIC POWER APPLICATIONS, 2008, 2 (02) :121-134
[2]  
Chen Mingmin., 2014, Encyclopedia of science education, P1
[3]   The state of the art of wind energy conversion systems and technologies: A review [J].
Cheng, Ming ;
Zhu, Ying .
ENERGY CONVERSION AND MANAGEMENT, 2014, 88 :332-347
[4]   Design and evaluation of voltage measurement-based sectoral diagnosis method for inverter open switch faults of permanent magnet synchronous motor drives [J].
Choi, C. ;
Lee, W. .
IET ELECTRIC POWER APPLICATIONS, 2012, 6 (08) :526-532
[5]   Adding Inverter Fault Detection to Model-Based Predictive Control for Flying-Capacitor Inverters [J].
Druant, Joachim ;
Vyncke, Thomas ;
De Belie, Frederik ;
Sergeant, Peter ;
Melkebeek, Jan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (04) :2054-2063
[6]   Comparison of Methods for Permanent Magnet Eddy-Current Loss Computations With and Without Reaction Field Considerations in Axial Flux PMSM [J].
Hemeida, Ahmed ;
Sergeant, Peter ;
Vansompel, Hendrik .
IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (09)
[7]  
Huynh C., 2009, J ENG GAS TURB POWER, V131, P697
[8]   Development of a new fault-tolerant induction motor control strategy using an enhanced equivalent circuit model [J].
Jasim, O. ;
Sumner, M. ;
Gerada, C. ;
Arellano-Padilla, J. .
IET ELECTRIC POWER APPLICATIONS, 2011, 5 (08) :618-627
[9]   Online fault-detecting scheme of an inverter-fed permanent magnet synchronous motor under stator winding shorted turn and inverter switch open [J].
Kim, K. -H. ;
Gu, B. -G. ;
Jung, I. -S. .
IET ELECTRIC POWER APPLICATIONS, 2011, 5 (06) :529-539
[10]  
Kwon O., 2001, THESIS U CALIF, P33