Surface and form alterations in retrieved shoulder hemiarthroplasty

被引:6
作者
Buelhoff, Matthias [1 ,2 ]
Reinders, Joern [2 ]
Zeifang, Felix [1 ,2 ]
Raiss, Patric [1 ,2 ]
Mueller, Ulrike [2 ]
Kretzer, J. Philippe [2 ]
机构
[1] Heidelberg Univ, Clin Orthopaed & Trauma Surg, Heidelberg, Germany
[2] Heidelberg Univ, Lab Biomech & Implant Res, Schlierbacher Landstr 200a, D-69118 Heidelberg, Germany
关键词
Shoulder hemiarthroplasty; glenoid erosion; retrievals; roughness; cup arthroplasty; wear; form alteration; PRIMARY GLENOHUMERAL OSTEOARTHRITIS; FEMORAL COMPONENTS; FOLLOW-UP; ARTHROPLASTY; REPLACEMENT; MULTICENTER; ARTHRITIS; WEAR;
D O I
10.1016/j.jse.2016.08.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Shoulder hemiarthroplasty is a viable treatment for shoulder arthritis, particularly if the natural glenoid is still intact. One of the most common reasons for revision surgery is glenoid erosion, where the cartilage or bone is worn. The aim of the current study was to analyze whether the metallic articular surface of retrieved shoulder hemiarthroplasty is different from new implants. We hypothesized that the surface roughness would increase as a result of the articulation and that metallic wear would be detectable on the implants. Methods: Included were 13 retrieved and 3 new shoulder hemiarthroplasties. The surface roughness was measured on different sites of the surface (dome of the head and the rim). The implants were further measured using a coordinate measuring machine to gain information on volumetric wear and geometric alterations. The surface was analyzed with a scanning electron microscope to see marks of wear. Results: Compared with new implants, the surface roughness on the retrievals was significantly increased. The roughness parameters within the retrieval group were generally higher at the dome of the head than at the rim; however, this difference was not significant. Apart from shape deviations caused by deformation of the retrievals, no volumetric wear was detectable on the heads. Conclusions: The current results indicate that the roughness of the surface of the implant and the shape changes occur in vivo and that the material incurs damaged caused by the articulation against the softer cartilage or bone. Increasing roughness of the humeral component may be one cause for glenoid erosion over time. (C) 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:521 / 528
页数:8
相关论文
共 19 条
[1]   Total shoulder arthroplasty: Long-term survivorship, functional outcome, and quality of life [J].
Deshmukh, AV ;
Koris, M ;
Zurakowski, D ;
Thornhill, TS .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (05) :471-479
[2]   A comparison of hemiarthroplasty and total shoulder arthroplasty in the treatment of primary glenohumeral osteoarthritis:: Results of a multicenter study [J].
Edwards, TB ;
Kadakia, NR ;
Boulahia, A ;
Kempf, JF ;
Boileau, P ;
Némoz, C ;
Walch, G .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (03) :207-213
[3]   Wear in total knee arthroplasty-just a question of polyethylene? [J].
Kretzer, Jan Philippe ;
Reinders, Joern ;
Sonntag, Robert ;
Hagmann, Sebastien ;
Streit, Marcus ;
Jeager, Sebastian ;
Moradi, Babak .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (02) :335-340
[4]  
Levine William N, 2012, J Bone Joint Surg Am, V94, pe164, DOI 10.2106/JBJS.K.00603
[5]  
Lu Z, 1999, J BIOMED MATER RES, V48, P458, DOI 10.1002/(SICI)1097-4636(1999)48:4<458::AID-JBM9>3.3.CO
[6]  
2-2
[7]   Observations on retrieved glenoid components from total shoulder arthroplasty [J].
Nho, Shane J. ;
Nam, Denis ;
Ala, Owen L. ;
Craig, Edward V. ;
Warren, Russell F. ;
Wright, Timothy M. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (03) :371-378
[8]  
Que L, 2000, J BIOMED MATER RES, V53, P111, DOI 10.1002/(SICI)1097-4636(2000)53:1<111::AID-JBM15>3.3.CO
[9]  
2-P
[10]  
Raiss P, 2012, J BONE JOINT SURG BR, V94B, P671, DOI 10.1302/0301-620X.94B5.28831