Field investigations of stack ventilation in a residential building with multiple chimneys and tilted window in cold climate

被引:16
作者
Krzaczek, M. [1 ]
Florczuk, J. [1 ]
Tejchman, J. [1 ]
机构
[1] Gdansk Univ Technol, Fac Civil & Environm Engn, PL-80233 Gdansk, Poland
关键词
Natural stack ventilation; Field measurements; Stack effect; Tilted horizontal pivot window; Multi-chimneys; INDOOR AIR-QUALITY; FLOW; RATES;
D O I
10.1016/j.enbuild.2015.06.034
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ventilation stacks are becoming increasingly common in the design of naturally ventilated buildings. They offer a method for achieving a fixed flow pattern irrespective of internal and external conditions. In this paper, the field measurements results are presented on the stack ventilation effect in a configuration with multi-chimneys which interact with tilted pivot windows. A residential two-family detached house was chosen to perform the measurement campaign. The house was located in a cold climate region in northern Poland. The measurements were performed in June during the time period of transient climate conditions between spring and summer. Local climate conditions, indoor climate conditions and air velocities in vent inlets and outlets were measured. In order to interpret measurement results, a modified model of a tilted pivot window with an axis at the bottom was proposed, based on a model used in single-sided ventilation investigations. The measured results confirmed the usefulness of the proposed approach. The loss coefficient (discharge coefficient) of 0.345 was lower than the loss coefficient of 0.60, usually assumed for small rectangular openings during natural ventilation. In the absence of wind when the stack effect acted only, the air changes per hour slightly exceeded the standard minimum value. The tilted window leeward wind significantly reduced the stack effect and ACH. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 61
页数:14
相关论文
共 31 条
  • [1] Stack ventilation in multi-storey atrium buildings: A dimensionless design approach
    Acred, Andrew
    Hunt, Gary R.
    [J]. BUILDING AND ENVIRONMENT, 2014, 72 : 44 - 52
  • [2] A simplified mathematical approach for modelling stack ventilation in multi-compartment buildings
    Acred, Andrew
    Hunt, Gary R.
    [J]. BUILDING AND ENVIRONMENT, 2014, 71 : 121 - 130
  • [3] Akimenko VV., 1986, Proceedings of Third International Conference on Indoor Air Quality and Climate, V6, P87
  • [4] [Anonymous], 2007, 15242 EN
  • [5] [Anonymous], PN83B03430
  • [6] Awbi H.B., 2003, Ventilation of Buildings
  • [7] Inter-related effects of cooling strategies and building features on energy performance of office buildings
    Becker, R
    Paciuk, M
    [J]. ENERGY AND BUILDINGS, 2002, 34 (01) : 25 - 31
  • [8] Brown W.G., 1962, INT J HEAT MASS TRAN, V5, P859
  • [9] Full scale experimental study of single-sided ventilation: Analysis of stack and wind effects
    Caciolo, Marcello
    Stabat, Pascal
    Marchio, Dominique
    [J]. ENERGY AND BUILDINGS, 2011, 43 (07) : 1765 - 1773
  • [10] Experimental technique to determine unsteady flow in natural ventilation stacks at model scale
    Chiu, YH
    Etheridge, DW
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2004, 92 (3-4) : 291 - 313