Calibration of DEM models for irregular particles based on experimental Check for design method and bulk experiments

被引:61
作者
Zhou, Haili [1 ,2 ]
Hu, Zhanqi [1 ,2 ]
Chen, Jigang [1 ,2 ]
Lv, Xuan [1 ,2 ]
Xie, Nan [1 ,2 ]
机构
[1] YanShan Univ, Sch Mech Engn, Qinhuangdao 066004, Peoples R China
[2] YanShan Univ, Aviat Key Lab Sci & Technol Gener Technol Aviat S, Qinhuangdao 066004, Peoples R China
关键词
Discrete element method; Parameter calibration; Optimal Latin hypercube sampling; Radial basis function neural network; Optimization; Irregular particle; DISCRETE ELEMENT MODELS; SIMULATION; PARAMETERS;
D O I
10.1016/j.powtec.2018.03.064
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Discrete element method (DEM) is widely used in particle modeling and related applications. DEM modeling requires a large number of micro particle parameters, which are difficult to measure for irregular particles, thus the parameter calibration method is introduced. This paper presents a new DEM parameter calibration method: taking the angle of repose and bulk density of expanded graphite (EG) particles as macro responses, the particle density, sliding frictions, coefficients of restitution and Poisson's ratio as micro variables, the micro particle parameters are calibrated with adaptive simulated annealing (ASA) optimization algorithm by establishing radial basis function neural network (RBFNN) approximate models between the micro variables and the macro responses based on optimal Latin hypercube sampling and virtual simulation experiments implemented in the commercial software EDEM. A baffle lift method is used to measure the angle of repose, and the fuzzy membership function is used to fit the measurements of the responses considering the dispersion of the experimental values of irregular particles. In addition, based on the membership degree, experimental truth values are defined, optimization conditions are determined and calibration results are evaluated. Finally, the dynamic angle of repose of the EG particles is obtained by a rotary cylinder experiment to further verify the calibrated parameters. The results show that: a) incorporating the measurement errors in the calibration process can help to improve the calibration efficiency without compromising the calibration accuracy; b) with high precision, the approximate model established by RBFNN can accurately predict the macro response values as an effective alternative to DEM model; c) the calibration results are a set of feasible solutions with each calibrated parameter distributed over a small range; d) the membership degree of the validated DEM results to the experimental truth values is high and the simulation result of the dynamic angle of repose is in good agreement with the experimental data, indicating that the calibrated micro DEM parameters can truly reproduce the particle stacking behavior, which proves the effectiveness and reliability of the proposed method. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:210 / 223
页数:14
相关论文
共 50 条
  • [31] Optimisation of a circularly vibrating screen based on DEM simulation and Taguchi orthogonal experimental design
    Zhao, Lala
    Zhao, Yuemin
    Bao, Chunyong
    Hou, Qinfu
    Yu, Aibing
    POWDER TECHNOLOGY, 2017, 310 : 307 - 317
  • [32] Reduction of number of simulations for parameters identification of DEM models using neural network and design of experiments
    Vieira Matos, Mauro Sergio
    Bezerra Vale, Jessica Caroline
    Amarante Mesquita, Alexandre Luiz
    MATERIA-RIO DE JANEIRO, 2022, 27 (01):
  • [33] Establishment of a Discrete Element Model for Wheat Particles Based on the Ellipsoidal Method and CFD-DEM Coupling
    Gu, Boxuan
    Hu, Can
    Xing, Jianfei
    He, Xiaowei
    Wang, Xufeng
    Ren, Kai
    Wang, Long
    AGRICULTURE-BASEL, 2025, 15 (04):
  • [34] Mixing assessment of non-cohesive particles in a paddle mixer through experiments and discrete element method (DEM)
    Yaraghi, Amirsalar
    Ebrahimi, Mohammadreza
    Ein-Mozaffari, Farhad
    Lohi, Ali
    ADVANCED POWDER TECHNOLOGY, 2018, 29 (11) : 2693 - 2706
  • [35] An experimental-numerical method for the calibration of finite element models of the lumbar spine
    Nicolini, Luis Fernando
    Beckmann, Agnes
    Laubach, Markus
    Hildebrand, Frank
    Kobbe, Philipp
    Roesler, Carlos Rodrigo de Mello
    Fancello, Eduardo Alberto
    Markert, Bernd
    Stoffel, Marcus
    MEDICAL ENGINEERING & PHYSICS, 2022, 107
  • [36] Development of an Adaptive Experimental Design Method Based on Probability of Achieving a Target Range through Parallel Experiments
    Nakao, Atsuyuki
    Kaneko, Hiromasa
    Funatsu, Kimito
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (19) : 5726 - 5735
  • [37] MAIZE STRAW CUTTING PROCESS MODELLING AND PARAMETER CALIBRATION BASED ON DISCRETE ELEMENT METHOD (DEM)
    Zheng, Zhiqi
    Zhao, Hongbo
    Liu, Peng
    He, Jin
    INMATEH-AGRICULTURAL ENGINEERING, 2021, 63 (01): : 461 - 468
  • [38] DEM study on mixing behaviors of concave-shaped particles in rotating drum based on level-set method
    Wang, Siqiang
    Liang, Dongfang
    Ji, Shunying
    POWDER TECHNOLOGY, 2023, 430
  • [39] A Research on the Macroscopic and Mesoscopic Parameters of Concrete Based on an Experimental Design Method
    Su, Hui
    Li, Hongliang
    Hu, Baowen
    Yang, Jiaqi
    MATERIALS, 2021, 14 (07)
  • [40] Efficient optimization parameter calibration method-based DEM simulation for compacted loess slope under dry-wet cycling
    Li, Liang
    Hu, Changming
    Yuan, Yili
    He, Xiaowen
    Wu, Zhipeng
    SCIENTIFIC REPORTS, 2024, 14 (01):