共 2 条
Validation of Computerized Sniffer for Monitoring Perioperative Normothermia
被引:3
作者:
Giri, Jyothsna
[1
]
Li, Man
[2
]
Pickering, Brian
[1
]
Subramanian, Arun
[1
]
Kor, Daryl J.
[1
]
Herasevich, Vitaly
[1
]
机构:
[1] Mayo Clin, Dept Anesthesiol, Div Crit Care Med, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Informat Technol, New Rochelle, NY USA
来源:
MEDINFO 2013: PROCEEDINGS OF THE 14TH WORLD CONGRESS ON MEDICAL AND HEALTH INFORMATICS, PTS 1 AND 2
|
2013年
/
192卷
关键词:
Hypothermia;
validation studies;
sensitivity and specificity;
D O I:
10.3233/978-1-61499-289-9-943
中图分类号:
R19 [保健组织与事业(卫生事业管理)];
学科分类号:
摘要:
Introduction: The World Health Organization sets a standard to maintain patient core temperature greater than 36 degrees C throughout the perioperative period. Normothermia (defined as > 36 degrees C) in the Operating Room (OR) is an important factor to preventing complications in patients (MI, infection, coagulopathy). Randomized studies suggests that maintaining at higher temperatures may further reduce complications in surgery (less complications for group at 36.4 degrees C than the control group at 36.0 degrees C) [1,2]. Perioperative normothermia is an important but often unrecognized element during anesthesia. Early recognition of hypothermia would allow for appropriate interventions and prevent complications. Methodology: Manual validation of the diagnostic performance a clinical tool (alert) that would automatically measure changes in core temperature to identify patients who fail to be in range of normothermia during surgery. Results: The clinical tool(alert) was found to be 97 % sensitive.
引用
收藏
页码:943 / 943
页数:1
相关论文