Test Study on Corona Onset Voltage of UHV Transmission Lines Based on UV Detection

被引:0
作者
Liu Yun-peng [1 ]
Wang Hui-bin [1 ]
Chen Wei-jiang [2 ]
Yang Ying-jian [2 ]
Tang Jian [2 ]
机构
[1] North China Elect Power Univ, Sch Elect & Elect Engn, Baoding 071003, Peoples R China
[2] Elect Power Res Inst SGCC, Wuhan 430074, Peoples R China
来源
ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION | 2008年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Corona discharge is being detected by UV imaging detection technology at home and abroad in recent years. This technology is used in the corona tests of bundled conductors in this paper. In order to further research the corona characteristic, optimize geometry parameters and diameter of sub-conductor, and increase corona onset voltage of transmission lines, corona tests of three mode conductors which are placed inside the outdoor corona cage are conducted. Corona cage could be used to simulate the corona activities on transmission lines under a low voltage and different conditions in an effective and economical way. Photon which was created by UV light as a result of corona discharge on conductors is detected by the UV detection apparatus. The photon number within unit interval, namely photon counting rate is adopted as the parameter of quantifying the intensity of corona discharge. According to the apparent change of photon number, corona onset voltage can be judged. All tests are conducted under almost same atmosphere condition. Using the method, corona onset voltage is acquired. The results indicate that the tests have a good repeatability, in other words, repeat same test twice can acquires same result. The corona onset voltage can be acquired exactly from the curve of applied voltage vs. photon counting rate. Therefore UV detection apparatus can not only used to find discharge point exactly, but also applied on corona discharge research and live detection for power equipments. The method using in this paper is proved that is a new available method.
引用
收藏
页码:387 / +
页数:2
相关论文
共 50 条
[31]   Corona Onset Voltage of Bipolar Bundle Conductors of HVDC Transmission Line [J].
Li, Zhong-Xin ;
Li, Guang-Fan ;
Fan, Jian-Bin ;
Yu, Yin .
IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (02) :693-702
[32]   Study of corona discharge pattern on high voltage transmission lines for inspecting faulty porcelain insulators [J].
Cheng, Yangchun ;
Li, Chengrong ;
Huang, Xingquan .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (02) :945-952
[33]   Differential protection based on calculated power for UHV transmission lines [J].
Wang, Liping ;
Wang, Xiaoru .
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2013, 33 (19) :174-182
[34]   Computation of Radio Interference Levels in High Voltage Transmission Lines with Corona [J].
Tejada, C. ;
Gomez, P. ;
Escamilla, J. C. .
IEEE LATIN AMERICA TRANSACTIONS, 2009, 7 (01) :54-61
[35]   The Optimum Method for Determining the Corona Onset Voltage Gradient of Bundle Conductors on UHV AC Power Line [J].
Shi-long Huang ;
Yun-Peng Liu .
Journal of Electrical Engineering & Technology, 2019, 14 :1777-1780
[36]   ELECTROSTATIC ANALYSIS OF TRANSMISSION LINES TO SIMULATE CORONA DISCHARGE AT HIGH VOLTAGE [J].
Serteller, N. F. Oyman .
PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2011, 20 :107-113
[37]   The Optimum Method for Determining the Corona Onset Voltage Gradient of Bundle Conductors on UHV AC Power Line [J].
Huang, Shi-long ;
Liu, Yun-Peng .
JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2019, 14 (04) :1777-1780
[38]   A Study on the Transient of Secondary Arc Current of UHV Transmission Lines [J].
Sun, Qiuqin ;
Xiao, Zhibin ;
Liu, Hongshun ;
Li, Qingmin ;
Wang, Feng .
IEEE ACCESS, 2018, 6 :38616-38626
[39]   A Pilot Study of a Novel TCSC Scheme for the UHV Transmission Lines [J].
Hu Zhen Da ;
Dai Chao Bo ;
Wu Shou Yuan .
2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
[40]   On the corona voltage-current characteristic of unipolar HVDC transmission lines [J].
Li, X ;
Raghuveer, MR ;
Ciric, IR .
IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, :654-657