Test Study on Corona Onset Voltage of UHV Transmission Lines Based on UV Detection

被引:0
作者
Liu Yun-peng [1 ]
Wang Hui-bin [1 ]
Chen Wei-jiang [2 ]
Yang Ying-jian [2 ]
Tang Jian [2 ]
机构
[1] North China Elect Power Univ, Sch Elect & Elect Engn, Baoding 071003, Peoples R China
[2] Elect Power Res Inst SGCC, Wuhan 430074, Peoples R China
来源
ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION | 2008年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Corona discharge is being detected by UV imaging detection technology at home and abroad in recent years. This technology is used in the corona tests of bundled conductors in this paper. In order to further research the corona characteristic, optimize geometry parameters and diameter of sub-conductor, and increase corona onset voltage of transmission lines, corona tests of three mode conductors which are placed inside the outdoor corona cage are conducted. Corona cage could be used to simulate the corona activities on transmission lines under a low voltage and different conditions in an effective and economical way. Photon which was created by UV light as a result of corona discharge on conductors is detected by the UV detection apparatus. The photon number within unit interval, namely photon counting rate is adopted as the parameter of quantifying the intensity of corona discharge. According to the apparent change of photon number, corona onset voltage can be judged. All tests are conducted under almost same atmosphere condition. Using the method, corona onset voltage is acquired. The results indicate that the tests have a good repeatability, in other words, repeat same test twice can acquires same result. The corona onset voltage can be acquired exactly from the curve of applied voltage vs. photon counting rate. Therefore UV detection apparatus can not only used to find discharge point exactly, but also applied on corona discharge research and live detection for power equipments. The method using in this paper is proved that is a new available method.
引用
收藏
页码:387 / +
页数:2
相关论文
共 50 条
[21]   Corona Onset Characteristics of Bundle Conductors in UHV AC Power Lines at 2200 m Altitude [J].
Huang, Shilong ;
Liu, Yunpeng ;
Chen, Shaoshuai ;
Zhou, Guangyang ;
Zhuang, Wenbing .
ENERGIES, 2018, 11 (05)
[22]   Confirmities of voltage and reactive power optimum control in UHV overhead transmission lines [J].
AzNIIenergetika .
Avtom, 2 (2-9)
[23]   Research on high-voltage reactor compensation of UHV AC transmission lines [J].
Yi, Qiang ;
Zhou, Hao ;
Ji, Rong-Rong ;
Xu, Qiong-Jing ;
Su, Fei ;
Sun, Ke ;
Chen, Jia-Miao .
Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (20) :98-105
[24]   Calculation of Induced Voltage and Current on a Crossing Transmission Line under UHV AC Transmission Lines [J].
Li Yuze ;
Kong Xiaofeng ;
Zhang Bo .
2019 IEEE ASIA POWER AND ENERGY ENGINEERING CONFERENCE (APEEC 2019), 2019, :132-136
[25]   Research on power frequency over-voltage in UHV AC transmission lines [J].
Sun, Ke ;
Yi, Qiang ;
Dong, Chaowu ;
Zhou, Hao .
Dianwang Jishu/Power System Technology, 2010, 34 (12) :30-35
[26]   Analysis of lightning shielding failure proof level of UHV transmission lines considering corona influences [J].
Yuan, Hai-Yan ;
Fu, Zheng-Cai ;
Wei, Ben-Gang ;
Sun, Wei .
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2009, 29 (25) :111-117
[27]   Attempt of the sound level evaluation for the corona noise of UHV transmission lines in the intensified interference conditions [J].
Wszolek, T ;
Tadeusiewicz, R ;
Wszolek, W ;
Izworski, A .
INTER-NOISE 99: PROCEEDINGS OF THE 1999 INTERNATIONAL CONGRESS ON NOISE CONTROL ENGINEERING, VOLS 1-3, 1999, :91-94
[28]   Corona loss characteristics of bundle conductors in UHV AC transmission lines at 2200 m altitude [J].
Huang Shilong ;
Liu Yunpeng ;
Chen Shaoshuai ;
He Wangling ;
Wan Baoquan ;
Xu Lihua ;
Li Yongjie .
ELECTRIC POWER SYSTEMS RESEARCH, 2019, 166 :83-87
[29]   Design and optimization of Hilbert fractal antenna for corona discharge detection of high-voltage transmission lines [J].
Xiao, Xiaoming ;
Wang, Qin ;
Hu, Weinan ;
Ran, Jun .
OPTOELECTRONIC MATERIALS AND DEVICES (ICOMD 2020), 2021, 11767
[30]   A method of fast faulted phase detection suitable for UHV transmission lines [J].
Liang, Jing-Fang ;
Gao, Hou-Lei ;
Su, Wen-Bo ;
Wang, Da-Peng ;
Zou, Gui-Bin .
Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (15) :95-99