Test Study on Corona Onset Voltage of UHV Transmission Lines Based on UV Detection

被引:0
|
作者
Liu Yun-peng [1 ]
Wang Hui-bin [1 ]
Chen Wei-jiang [2 ]
Yang Ying-jian [2 ]
Tang Jian [2 ]
机构
[1] North China Elect Power Univ, Sch Elect & Elect Engn, Baoding 071003, Peoples R China
[2] Elect Power Res Inst SGCC, Wuhan 430074, Peoples R China
来源
ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION | 2008年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Corona discharge is being detected by UV imaging detection technology at home and abroad in recent years. This technology is used in the corona tests of bundled conductors in this paper. In order to further research the corona characteristic, optimize geometry parameters and diameter of sub-conductor, and increase corona onset voltage of transmission lines, corona tests of three mode conductors which are placed inside the outdoor corona cage are conducted. Corona cage could be used to simulate the corona activities on transmission lines under a low voltage and different conditions in an effective and economical way. Photon which was created by UV light as a result of corona discharge on conductors is detected by the UV detection apparatus. The photon number within unit interval, namely photon counting rate is adopted as the parameter of quantifying the intensity of corona discharge. According to the apparent change of photon number, corona onset voltage can be judged. All tests are conducted under almost same atmosphere condition. Using the method, corona onset voltage is acquired. The results indicate that the tests have a good repeatability, in other words, repeat same test twice can acquires same result. The corona onset voltage can be acquired exactly from the curve of applied voltage vs. photon counting rate. Therefore UV detection apparatus can not only used to find discharge point exactly, but also applied on corona discharge research and live detection for power equipments. The method using in this paper is proved that is a new available method.
引用
收藏
页码:387 / +
页数:2
相关论文
共 50 条
  • [1] Simulation and Experimental Study on Corona Noise Distribution of UHV Transmission Lines
    Zhao, Guo
    Song, Haoran
    Zhu, Heping
    Li, Shulin
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2025, 18 (03) : 292 - 305
  • [2] Corona Onset Voltage Gradient of Bundle Conductors for EHV/UHV AC Power Lines in Corona Cages Considering Altitude Correction
    Huang, Shilong
    Liu, Yunpeng
    Chen, Shaoshuai
    Liu, Daran
    He, Wangling
    Wan, Baoquan
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2020, 6 (03): : 693 - 703
  • [3] USE OF SINGLE-PHASE OVERHEAD TEST LINES AND TEST CAGES TO EVALUATE CORONA EFFECTS OF EHV AND UHV TRANSMISSION-LINES
    COMBER, MG
    ZAFFANELLA, LE
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1974, PA93 (01): : 81 - 90
  • [4] Negative Corona Onset Characteristic of the UHV Conductors Based on the Corona Cage
    Liu, Yun-Peng
    Zhu, Lei
    Lv, Fang-Cheng
    Xie, Xiongjie
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (06) : 2089 - 2097
  • [5] Corona streamer onset as an optimization criterion for design of high voltage hardware on transmission lines
    Pedrow, PD
    Olsen, RG
    CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 312 - 315
  • [6] Study on Assessment and Countermeasures of Induced Voltage on Distribution Lines under EHV/UHV Transmission Lines
    He, Yuwei
    Wei, Bengang
    Jiang, Anfeng
    Wang, Liming
    Fu, Zhengcai
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014, : 1582 - 1587
  • [7] STUDIES ON CORONA PERFORMANCE OF INSULATOR ASSEMBLIES FOR UHV TRANSMISSION-LINES
    FUJIMURA, T
    NAITO, K
    HASEGAWA, Y
    MATSUOKA, R
    NAKASHIMA, Y
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (03): : 860 - 870
  • [8] Corona Performance of Double Pendulum Damper for UHV AC Transmission Lines
    Quan S.
    Li F.
    Zhang R.
    Deng J.
    Zhang H.
    Yuan G.
    Dianwang Jishu/Power System Technology, 2023, 47 (10): : 4342 - 4348
  • [9] Lightning Impulse Corona Characteristic of 1000 kV UHV Transmission Lines
    He, Jinliang
    Yang, Pengcheng
    Chen, Shuiming
    Zeng, Rong
    2013 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XII SIPDA), 2013, : 108 - 112
  • [10] A fast calculation for the surface electric field distribution and onset corona voltage of HVDC transmission lines
    Wang, Hui
    Hao, Jianhong
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018, : 834 - 838