Automated extraction of fine features of kinetochore microtubules and plus-ends from electron tomography volume

被引:7
作者
Jiang, Ming [1 ]
Ji, Qiang
McEwen, Bruce F.
机构
[1] Rensselaer Polytech Inst, Dept Elect Comp & Syst Engn, Troy, NY 12180 USA
[2] New York State Dept Hlth, Wadsworth Ctr, Albany, NY 12201 USA
关键词
electron tomography; image enhancement; microtubule; model-based segmentation; plus-end;
D O I
10.1109/TIP.2006.877054
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Kinetochore microtubules (KMTs) and the associated plus-ends have been areas of intense investigation in both cell biology and molecular medicine. Though electron tomography opens up new possibilities in understanding their function by imaging their high-resolution structures, the interpretation of the acquired data remains an obstacle because of the complex and cluttered cellular environment. As a result, practical segmentation of the electron tomography data has been dominated by manual operation, which is time consuming and subjective. In this paper, we propose a model-based automated approach to extracting KMTs and the associated plus-ends with a coarse-to-fine scale scheme consisting of volume preprocessing, microtubule segmentation and plus-end tracing. In volume preprocessing, we first apply an anisotropic invariant wavelet transform and a tube-enhancing filter to enhance the microtubules at coarse level for localization. This is followed with a surface-enhancing filter to accentuate the fine microtubule boundary features. The microtubule body is then segmented using a modified active shape model method. Starting from the segmented microtubule body, the plus-ends are extracted with a probabilistic tracing method improved with rectangular window based feature detection and the integration of multiple cues. Experimental results demonstrate that our automated method produces results comparable to manual segmentation but using only a fraction of the manual segmentation time.
引用
收藏
页码:2035 / 2048
页数:14
相关论文
共 51 条
[51]   Automated high-throughput electron tomography by pre-calibration of image shifts [J].
Ziese, U ;
Janssen, AH ;
Murk, JL ;
Geerts, WJC ;
Van der Krift, T ;
Verkleij, AJ ;
Koster, AJ .
JOURNAL OF MICROSCOPY, 2002, 205 (02) :187-200