Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy

被引:31
|
作者
Guinot, P. -G. [1 ]
de Broca, B. [1 ]
Bernard, E. [1 ]
Abou Arab, O. [1 ]
Lorne, E. [1 ,2 ]
Dupont, H. [1 ,2 ]
机构
[1] Amiens Univ Hosp, Anaesthesiol & Crit Care Dept, F-80054 Amiens, France
[2] Jules Verne Univ Picardy, INSERM, ERI12, F-80000 Amiens, France
关键词
anaesthesia; Doppler; intraoperative; laparoscopy; monitoring; stroke volume; INCREASED INTRAABDOMINAL PRESSURE; SYSTEMIC VASCULAR-RESISTANCE; PULSE PRESSURE; CARDIAC-OUTPUT; PNEUMOPERITONEUM; OPTIMIZATION;
D O I
10.1093/bja/aet430
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was designed to assess the ability of the stroke volume respiratory variation (respSV) determined by oesophageal Doppler monitoring (ODM) to predict the response to volume expansion (VE) during pneumoperitoneum. The predictive value of respSV was evaluated according to the concept of the grey zone. Patients operated on laparoscopy and monitored by ODM were prospectively included. The exclusion criteria were frequent ectopic beats or preoperative arrhythmia, right ventricular failure, and spontaneous breathing. Haemodynamic parameters and oesophageal Doppler indices [stroke volume (SV), peak velocity (PV), cardiac output (CO), corrected flow time (FTc), respiratory variation of PV (respPV) and SV (respSV)] were collected before and after VE. Responders were defined as a 15 increase in SV after VE. Thirty-eight (64) of the 59 patients were responders. A cut-off of 14 respSV predicted fluid responsiveness with an area under the ROC curve (AUC) of 0.92 [95 confidence interval (CI): 0.820.98, P0.0001]. The grey zone of respSV ranged between 13 and 15. With an AUC of 0.71 (95 CI: 0.560.83, P0.005), respPV fairly accurately predicted fluid responsiveness. FTc was unable to accurately predict fluid responsiveness. respSV and respPV predicted fluid responsiveness during laparoscopy under strict physiological conditions. FTc was not predictive of fluid responsiveness during laparoscopy.
引用
收藏
页码:660 / 664
页数:5
相关论文
共 50 条
  • [41] Comparison of stroke volume variation with pulse pressure variation as a diagnostic indicator of fluid responsiveness in mechanically ventilated critically ill patients
    Hong, Jin-Quan
    He, He-Fan
    Chen, Zhi-Yuan
    Du, Zhen-Shuang
    Liu, Wei-Feng
    Weng, Pei-Qing
    Huang, Hao-Bo
    SAUDI MEDICAL JOURNAL, 2014, 35 (03) : 261 - 268
  • [42] Comparison of stroke volume (SV) and stroke volume respiratory variation (SVV) measured by the axillary artery pulse-contour method and by aortic Doppler echocardiography in patients undergoing aortic surgery
    De Castro, V.
    Goarin, J. -P.
    Lhotel, L.
    Mabrouk, N.
    Perel, A.
    Coriat, P.
    BRITISH JOURNAL OF ANAESTHESIA, 2006, 97 (05) : 605 - 610
  • [43] Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review
    Chen, Jiaxin
    Zhao, Shuhua
    Zhu, Qianqian
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (02) : 379 - 387
  • [44] Automated pre-ejection period variation indexed to tidal volume predicts fluid responsiveness after cardiac surgery
    Vistisen, S. T.
    Struijk, J. J.
    Larsson, A.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (04) : 534 - 542
  • [45] Pulse pressure variation and stroke volume variation predict fluid responsiveness in mechanically ventilated patients experiencing intra-abdominal hypertension
    Liu, Xiaomei
    Fu, Qiang
    Mi, Weidong
    Liu, Henian
    Zhang, Hong
    Wang, Peiji
    BIOSCIENCE TRENDS, 2013, 7 (02) : 101 - 108
  • [46] Stroke volume variation during hemorrhage and after fluid loading: impact of different tidal volumes
    Renner, J.
    Cavus, E.
    Meybohm, P.
    Tonner, P.
    Steinfath, M.
    Scholz, J.
    Lutter, G.
    Bein, B.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (05) : 538 - 544
  • [47] Stroke volume variation obtained with Vigileo/FloTrac™ system during bleeding and fluid overload in dogs
    Hiroyuki Taguchi
    Keisuke Ichinose
    Hironari Tanimoto
    Michiko Sugita
    Masafumi Tashiro
    Tatsuo Yamamoto
    Journal of Anesthesia, 2011, 25
  • [48] Stroke volume variation obtained with Vigileo/FloTrac™ system during bleeding and fluid overload in dogs
    Taguchi, Hiroyuki
    Ichinose, Keisuke
    Tanimoto, Hironari
    Sugita, Michiko
    Tashiro, Masafumi
    Yamamoto, Tatsuo
    JOURNAL OF ANESTHESIA, 2011, 25 (04) : 563 - 568
  • [49] Comparative evaluation of stroke volume variation and inferior vena cava distensibility index for prediction of fluid responsiveness in mechanically ventilated patients
    Kaur, Kaminder Bir
    Nakra, Monish
    Mangal, Vishal
    Singh, Shalendra
    Taank, Priya
    Marwah, Vikas
    ANNALS OF CARDIAC ANAESTHESIA, 2021, 24 (03) : 327 - 332
  • [50] Changes in stroke volume induced by lung recruitment maneuver can predict fluid responsiveness during intraoperative lung-protective ventilation in prone position
    Watanabe, Ryota
    Suehiro, Koichi
    Mukai, Akira
    Tanaka, Katsuaki
    Yamada, Tokuhiro
    Mori, Takashi
    Nishikawa, Kiyonobu
    BMC ANESTHESIOLOGY, 2021, 21 (01)