Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy

被引:31
|
作者
Guinot, P. -G. [1 ]
de Broca, B. [1 ]
Bernard, E. [1 ]
Abou Arab, O. [1 ]
Lorne, E. [1 ,2 ]
Dupont, H. [1 ,2 ]
机构
[1] Amiens Univ Hosp, Anaesthesiol & Crit Care Dept, F-80054 Amiens, France
[2] Jules Verne Univ Picardy, INSERM, ERI12, F-80000 Amiens, France
关键词
anaesthesia; Doppler; intraoperative; laparoscopy; monitoring; stroke volume; INCREASED INTRAABDOMINAL PRESSURE; SYSTEMIC VASCULAR-RESISTANCE; PULSE PRESSURE; CARDIAC-OUTPUT; PNEUMOPERITONEUM; OPTIMIZATION;
D O I
10.1093/bja/aet430
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was designed to assess the ability of the stroke volume respiratory variation (respSV) determined by oesophageal Doppler monitoring (ODM) to predict the response to volume expansion (VE) during pneumoperitoneum. The predictive value of respSV was evaluated according to the concept of the grey zone. Patients operated on laparoscopy and monitored by ODM were prospectively included. The exclusion criteria were frequent ectopic beats or preoperative arrhythmia, right ventricular failure, and spontaneous breathing. Haemodynamic parameters and oesophageal Doppler indices [stroke volume (SV), peak velocity (PV), cardiac output (CO), corrected flow time (FTc), respiratory variation of PV (respPV) and SV (respSV)] were collected before and after VE. Responders were defined as a 15 increase in SV after VE. Thirty-eight (64) of the 59 patients were responders. A cut-off of 14 respSV predicted fluid responsiveness with an area under the ROC curve (AUC) of 0.92 [95 confidence interval (CI): 0.820.98, P0.0001]. The grey zone of respSV ranged between 13 and 15. With an AUC of 0.71 (95 CI: 0.560.83, P0.005), respPV fairly accurately predicted fluid responsiveness. FTc was unable to accurately predict fluid responsiveness. respSV and respPV predicted fluid responsiveness during laparoscopy under strict physiological conditions. FTc was not predictive of fluid responsiveness during laparoscopy.
引用
收藏
页码:660 / 664
页数:5
相关论文
共 50 条
  • [11] Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
    Marx, G
    Cope, T
    McCrossan, L
    Swaraj, S
    Cowan, C
    Mostafa, SM
    Wenstone, R
    Leuwer, M
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (02) : 132 - 138
  • [12] Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation
    Biais, M.
    Nouette-Gaulain, K.
    Cottenceau, V.
    Revel, P.
    Sztark, F.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) : 761 - 768
  • [13] Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation
    Khwannimit, Bodin
    Bhurayanontachai, Rungsun
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2012, 29 (02) : 64 - 69
  • [14] Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients
    Xavier Monnet
    Mario Rienzo
    David Osman
    Nadia Anguel
    Christian Richard
    Michael R. Pinsky
    Jean-Louis Teboul
    Intensive Care Medicine, 2005, 31 : 1195 - 1201
  • [15] Stroke volume averaging for individualized goal-directed fluid therapy with oesophageal Doppler
    Jorgensen, C. C.
    Bundgaard-Nielsen, M.
    Skovgaard, L. T.
    Secher, N. H.
    Kehlet, H.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (01) : 34 - 38
  • [16] Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model
    Renner, Jochen
    Gruenewald, Matthias
    Quaden, Rene
    Hanss, Robert
    Meybohm, Patrick
    Steinfath, Markus
    Scholz, Jens
    Bein, Berthold
    CRITICAL CARE MEDICINE, 2009, 37 (02) : 650 - 658
  • [17] l Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy
    Kim, Kyung Mi
    Gwak, Mi Sook
    Choi, Soo Joo
    Kim, Myung Hee
    Park, Mi Hye
    Heo, Burn Young
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2013, 65 (03) : 237 - 243
  • [18] Utility of stroke volume variation measured using non-invasive bioreactance as a predictor of fluid responsiveness in the prone position
    Jeong Jin Min
    Jong-Hwan Lee
    Kwan Young Hong
    Soo Joo Choi
    Journal of Clinical Monitoring and Computing, 2017, 31 : 397 - 405
  • [19] STROKE VOLUME VARIATION AS AN INDEX OF FLUID RESPONSIVENESS CAN BE IMPAIRED BY MENTAL STRESS
    Wiszt, R.
    Czippelova, B.
    Krohova, J. Cernanova
    Mazgutova, N.
    Turianikova, Z.
    Lazarova, Z.
    Javorka, M.
    JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2022, 73 (02): : 277 - 285
  • [20] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Marko Zlicar
    Vesna Novak-Jankovic
    Rok Blagus
    Maurizio Cecconi
    Journal of Clinical Monitoring and Computing, 2018, 32 : 825 - 832