Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy

被引:31
作者
Guinot, P. -G. [1 ]
de Broca, B. [1 ]
Bernard, E. [1 ]
Abou Arab, O. [1 ]
Lorne, E. [1 ,2 ]
Dupont, H. [1 ,2 ]
机构
[1] Amiens Univ Hosp, Anaesthesiol & Crit Care Dept, F-80054 Amiens, France
[2] Jules Verne Univ Picardy, INSERM, ERI12, F-80000 Amiens, France
关键词
anaesthesia; Doppler; intraoperative; laparoscopy; monitoring; stroke volume; INCREASED INTRAABDOMINAL PRESSURE; SYSTEMIC VASCULAR-RESISTANCE; PULSE PRESSURE; CARDIAC-OUTPUT; PNEUMOPERITONEUM; OPTIMIZATION;
D O I
10.1093/bja/aet430
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was designed to assess the ability of the stroke volume respiratory variation (respSV) determined by oesophageal Doppler monitoring (ODM) to predict the response to volume expansion (VE) during pneumoperitoneum. The predictive value of respSV was evaluated according to the concept of the grey zone. Patients operated on laparoscopy and monitored by ODM were prospectively included. The exclusion criteria were frequent ectopic beats or preoperative arrhythmia, right ventricular failure, and spontaneous breathing. Haemodynamic parameters and oesophageal Doppler indices [stroke volume (SV), peak velocity (PV), cardiac output (CO), corrected flow time (FTc), respiratory variation of PV (respPV) and SV (respSV)] were collected before and after VE. Responders were defined as a 15 increase in SV after VE. Thirty-eight (64) of the 59 patients were responders. A cut-off of 14 respSV predicted fluid responsiveness with an area under the ROC curve (AUC) of 0.92 [95 confidence interval (CI): 0.820.98, P0.0001]. The grey zone of respSV ranged between 13 and 15. With an AUC of 0.71 (95 CI: 0.560.83, P0.005), respPV fairly accurately predicted fluid responsiveness. FTc was unable to accurately predict fluid responsiveness. respSV and respPV predicted fluid responsiveness during laparoscopy under strict physiological conditions. FTc was not predictive of fluid responsiveness during laparoscopy.
引用
收藏
页码:660 / 664
页数:5
相关论文
共 23 条
[1]   Cardiac function during intraperitoneal CO2 insufflation for aortic surgery:: A transesophageal echocardiographic study [J].
Alfonsi, P ;
Vieillard-Baron, T ;
Coggia, M ;
Guignard, B ;
Goeau-Brissonniere, O ;
Jardin, F ;
Chauvin, M .
ANESTHESIA AND ANALGESIA, 2006, 102 (05) :1304-1310
[2]   Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum [J].
Bliacheriene, F. ;
Machado, S. B. ;
Fonseca, E. B. ;
Otsuke, D. ;
Auler, J. O. C., Jr. ;
Michard, F. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (09) :1268-1272
[3]   Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness A "Gray Zone" Approach [J].
Cannesson, Maxime ;
Le Manach, Yannick ;
Hofer, Christoph K. ;
Goarin, Jean Pierre ;
Lehot, Jean-Jacques ;
Vallet, Benoit ;
Tavernier, Benoit .
ANESTHESIOLOGY, 2011, 115 (02) :231-241
[4]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[5]   Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery [J].
Derichard, A. ;
Robin, E. ;
Tavernier, B. ;
Costecalde, M. ;
Fleyfel, M. ;
Onimus, J. ;
Lebuffe, G. ;
Chambon, J. -P. ;
Vallet, B. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (05) :678-684
[6]   Increased intra-abdominal pressure affects respiratory variations in arterial pressure in normovolaemic and hypovolaemic mechanically ventilated healthy pigs [J].
Duperret, Serge ;
Lhuillier, Franck ;
Piriou, Vincent ;
Vivier, Emmanuel ;
Metton, Olivier ;
Branche, Patricia ;
Annat, Guy ;
Bendjelid, Karim ;
Viale, Jean Paul .
INTENSIVE CARE MEDICINE, 2007, 33 (01) :163-171
[7]   Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery [J].
Guinot, P. -G. ;
de Broca, B. ;
Abou Arab, O. ;
Diouf, M. ;
Badoux, L. ;
Bernard, E. ;
Lorne, E. ;
Dupont, H. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (01) :28-33
[8]   Alterations of cardiovascular performance during laparoscopic colectomy: A combined hemodynamic and echocardiographic analysis [J].
Harris, SN ;
Ballantyne, GH ;
Luther, MA ;
Perrino, AC .
ANESTHESIA AND ANALGESIA, 1996, 83 (03) :482-487
[9]   Dynamic variables of fluid responsiveness during pneumoperitoneum and laparoscopic surgery [J].
Hoiseth, L. O. ;
Hoff, I. E. ;
Myre, K. ;
Landsverk, S. A. ;
Kirkeboen, K. A. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2012, 56 (06) :777-786
[10]   Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study [J].
Jacques, Didier ;
Bendjelid, Karim ;
Duperret, Serge ;
Colling, Joelle ;
Piriou, Vincent ;
Viale, Jean-Paul .
CRITICAL CARE, 2011, 15 (01)