Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy

被引:31
|
作者
Guinot, P. -G. [1 ]
de Broca, B. [1 ]
Bernard, E. [1 ]
Abou Arab, O. [1 ]
Lorne, E. [1 ,2 ]
Dupont, H. [1 ,2 ]
机构
[1] Amiens Univ Hosp, Anaesthesiol & Crit Care Dept, F-80054 Amiens, France
[2] Jules Verne Univ Picardy, INSERM, ERI12, F-80000 Amiens, France
关键词
anaesthesia; Doppler; intraoperative; laparoscopy; monitoring; stroke volume; INCREASED INTRAABDOMINAL PRESSURE; SYSTEMIC VASCULAR-RESISTANCE; PULSE PRESSURE; CARDIAC-OUTPUT; PNEUMOPERITONEUM; OPTIMIZATION;
D O I
10.1093/bja/aet430
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was designed to assess the ability of the stroke volume respiratory variation (respSV) determined by oesophageal Doppler monitoring (ODM) to predict the response to volume expansion (VE) during pneumoperitoneum. The predictive value of respSV was evaluated according to the concept of the grey zone. Patients operated on laparoscopy and monitored by ODM were prospectively included. The exclusion criteria were frequent ectopic beats or preoperative arrhythmia, right ventricular failure, and spontaneous breathing. Haemodynamic parameters and oesophageal Doppler indices [stroke volume (SV), peak velocity (PV), cardiac output (CO), corrected flow time (FTc), respiratory variation of PV (respPV) and SV (respSV)] were collected before and after VE. Responders were defined as a 15 increase in SV after VE. Thirty-eight (64) of the 59 patients were responders. A cut-off of 14 respSV predicted fluid responsiveness with an area under the ROC curve (AUC) of 0.92 [95 confidence interval (CI): 0.820.98, P0.0001]. The grey zone of respSV ranged between 13 and 15. With an AUC of 0.71 (95 CI: 0.560.83, P0.005), respPV fairly accurately predicted fluid responsiveness. FTc was unable to accurately predict fluid responsiveness. respSV and respPV predicted fluid responsiveness during laparoscopy under strict physiological conditions. FTc was not predictive of fluid responsiveness during laparoscopy.
引用
收藏
页码:660 / 664
页数:5
相关论文
共 50 条
  • [1] Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery
    Guinot, P. -G.
    de Broca, B.
    Abou Arab, O.
    Diouf, M.
    Badoux, L.
    Bernard, E.
    Lorne, E.
    Dupont, H.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (01) : 28 - 33
  • [2] Fluid responsiveness is about stroke volume, and not pulse pressure Yogi: the power of Doppler fluid management and cardiovascular monitoring
    Phillips, Rob
    Brierley, Joe
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) : 197 - 200
  • [3] Stroke volume variation and indexed stroke volume measured using bioreactance predict fluid responsiveness in postoperative children
    Vergnaud, E.
    Vidal, C.
    Verchere, J.
    Miatello, J.
    Meyer, P.
    Carli, P.
    Orliaguet, G.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 114 (01) : 103 - 109
  • [4] Fluid responsiveness is about stroke volume, and not pulse pressure Yogi: the power of Doppler fluid management and cardiovascular monitoring
    Rob Phillips
    Joe Brierley
    Journal of Clinical Monitoring and Computing, 2015, 29 : 197 - 200
  • [5] Utility of stroke volume variation measured using non-invasive bioreactance as a predictor of fluid responsiveness in the prone position
    Min, Jeong Jin
    Lee, Jong-Hwan
    Hong, Kwan Young
    Choi, Soo Joo
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (02) : 397 - 405
  • [6] Stroke Volume Variation and Pulse Pressure Variation Are Not Useful for Predicting Fluid Responsiveness in Thoracic Surgery
    Jeong, Dae Myoung
    Ahn, Hyun Joo
    Park, Hyo Won
    Yang, Mikyung
    Kim, Jie Ae
    Park, Joohyun
    ANESTHESIA AND ANALGESIA, 2017, 125 (04) : 1158 - 1165
  • [7] Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis
    Hoiseth, Lars Oivind
    Hoff, Ingrid Elise
    Hagen, Ove Andreas
    Landsverk, Svein Aslak
    Kirkeboen, Knut Arvid
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (04) : 435 - 441
  • [8] Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness
    Mallat, J.
    Meddour, M.
    Durville, E.
    Lemyze, M.
    Pepy, F.
    Temime, J.
    Vangrunderbeeck, N.
    Tronchon, L.
    Thevenin, D.
    Tavernier, B.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) : 449 - 456
  • [9] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Zlicar, Marko
    Novak-Jankovic, Vesna
    Blagus, Rok
    Cecconi, Maurizio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (05) : 825 - 832
  • [10] Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients
    Monnet, X
    Rienzo, M
    Osman, D
    Anguel, N
    Richard, C
    Pinsky, MR
    Teboul, JL
    INTENSIVE CARE MEDICINE, 2005, 31 (09) : 1195 - 1201