An intravitreal device providing sustained release of cyclosporine and dexamethasone

被引:44
|
作者
Enyedi, LB
Pearson, PA
Ashton, P
Jaffe, GJ
机构
[1] DUKE UNIV, CTR EYE, DEPT OPHTHALMOL, DURHAM, NC 27710 USA
[2] UNIV KENTUCKY, DEPT OPHTHALMOL, LEXINGTON, KY USA
关键词
dexamethasone; cyclosporine; intravitreal drug delivery; uveitis; proliferative vitreoretinopathy; rabbit;
D O I
10.3109/02713689609000766
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. A device that releases cyclosporine and dexamethasone into the eye for extended periods of time might be beneficial in diseases such as proliferative vitreoretinopathy and uveitis, In this study we examine the pharmacokinetics and toxicity of cyclosporine and dexamethasone combined in an intravitreal sustained-release device and the toxicity of a similar device containing only dexamethasone in rabbits. Methods. Rabbits were divided into three groups for (1) evaluation of the drug tissue levels and device release kinetics following implantation of a device containing 100 mu g of cyclosporine labeled with 2 mu Ci of H-3-cyclosporine and 2 mg of dexamethasone; (2) evaluation of the toxicity of this intravitreal device; and (3) evaluation of the toxicity of a similar device containing 2 mg of dexamethasone only. Cyclosporine was measured using a scintillation counter and dexamethasone was measured by high pressure liquid chromatography (HPLC). Toxicity was evaluated by electroretinography, clinical examination, and light microscopy. Results. Vitreous concentrations of cyclosporine (+/- standard deviation) averaged 0.06 (+/- 0.02) mu g/ml over 10 weeks, The average dexamethasone concentration over the 10 week period was 2.9 (+/- 0.9) mu g/ml. Devices containing cyclosporine and dexamethasone released each drug at rates similar to devices containing cyclosporine or dexamethasone alone. Devices containing both cyclosporine and dexamethasone caused reversible depressions in the b-wave amplitude of photopic and scotopic electroretinograms (ERG's). There was no evidence of toxicity associated with the devices containing dexamethasone only. There was no drug-related toxicity evident on clinical or histopathologic examination of eyes with devices containing the combination of cyclosporine and dexamethasone or dexamethasone alone. Conclusions. We conclude that the device maintains potentially therapeutic levels of both cyclosporine and dexamethasone in the vitreous. Reversible electroretinographic abnormalities are attributable to cyclosporine. A sustained-release device containing cyclosporine and dexamethasone may be useful for reducing inflammation in diseases such as proliferative vitreoretinopathy and uveitis.
引用
收藏
页码:549 / 557
页数:9
相关论文
共 50 条
  • [31] Sustained-release dexamethasone intravitreal implant in juvenile idiopathic arthritis-related uveitis
    Francesco Pichi
    Paolo Nucci
    Kimberly Baynes
    Careen Y. Lowder
    Sunil K. Srivastava
    International Ophthalmology, 2017, 37 : 221 - 228
  • [32] INTRAVITREAL SUSTAINED-RELEASE GANCICLOVIR
    SMITH, TJ
    PEARSON, PA
    BLANDFORD, DL
    BROWN, JD
    GOINS, KA
    HOLLINS, JL
    SCHMEISSER, ET
    GLAVINOS, P
    BALDWIN, LB
    ASHTON, P
    ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (02) : 255 - 258
  • [33] SUSTAINED-RELEASE GANCICLOVIR THERAPY FOR TREATMENT OF CYTOMEGALOVIRUS RETINITIS - USE OF AN INTRAVITREAL DEVICE
    SANBORN, GE
    ANAND, R
    TORTI, RE
    NIGHTINGALE, SD
    CAL, SX
    YATES, B
    ASHTON, P
    SMITH, T
    ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (02) : 188 - 195
  • [34] Fluocinolone acetonide intravitreal sustained release device - a new addition to the armamentarium of uveitic management
    Brumm, Matthew V.
    Nguyen, Quan Dong
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2007, 2 (01): : 55 - 64
  • [35] Intravitreal sustained-release fluocinolone acetonide device to treat severe experimental uveitis
    Srivastava, S
    Mruthyunjaya, P
    Wiser, J
    Peairs, J
    Stinnett, S
    Jaffe, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [36] An intravitreal sustained-release fluocinolone acetonide device to treat severe experimental uveitis
    Mruthyunjaya, P
    Khalatbari, D
    Yang, P
    Stinnett, S
    Hanes, M
    Jaffe, GJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U469 - U469
  • [37] IN-VIVO EVALUATION OF AN INTRAVITREAL SUSTAINED-RELEASE DRUG-DELIVERY DEVICE
    MOSHFEGHI, A
    PEYMAN, GA
    FILLACIER, K
    YANG, D
    KHOOBEHI, B
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S617 - S617
  • [38] Sustained-Release Dexamethasone Intravitreal Implant for Persistent Macular Edema After Vitrectomy for Epiretinal Membrane
    Taney, Lauren S.
    Baumal, Caroline R.
    Duker, Jay S.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2015, 46 (02): : 224 - 228
  • [39] PROSPECTIVE EVALUATION OF A SUSTAINED-RELEASE DEXAMETHASONE INTRAVITREAL IMPLANT FOR CYSTOID MACULAR EDEMA IN QUIESCENT UVEITIS
    Khurana, Rahul N.
    Bansal, Alok S.
    Chang, Louis K.
    Palmer, James D.
    Wu, Chengqing
    Wieland, Mark R.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (09): : 1692 - 1699
  • [40] Intravitreal sustained-release dexamethasone implant for the treatment of persistent cystoid macular edema in ocular syphilis
    Majumder, Parthopratim Dutta
    Mayilvakanam, Lakshmi
    Palker, Amit H.
    Sridharan, Sudharshan
    Biswas, Jyotirmay
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (09) : 1487 - +