A two-steps procedure is presented to convert dual-energy CT data to stopping power ratio (SPR), relative to water. In the first step the relative electron density (RED) is calculated from dual-energy CT-numbers by means of a bi-linear relationship: RED = a HUscH + b HUscL + c, where HUscH and HUscL are scaled units (HUsc = HU + 1000) acquired at high and low energy respectively, and the three parameters a, b and c has to be determined for each CT scanner. In the second step the RED values were converted into SPR by means of published poly-line functions, which are invariant as they do not depend on a specific CT scanner. The comparison with other methods provides encouraging results, with residual SPR error on human tissue within 1%. The distinctive features of the proposed method are its simplicity and the generality of the conversion functions.
引用
收藏
页码:7081 / 7084
页数:4
相关论文
共 7 条
[1]   Experimental verification of ion stopping power prediction from dual energy CT data in tissue surrogates [J].
Huenemohr, Nora ;
Krauss, Bernhard ;
Tremmel, Christoph ;
Ackermann, Benjamin ;
Jaekel, Oliver ;
Greilich, Steffen .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (01) :83-96
[2]   A CT calibration method based on the polybinary tissue model for radiotherapy treatment planning [J].
Kanematsu, N ;
Matsufuji, N ;
Kohno, R ;
Minohara, S ;
Kanai, T .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) :1053-1064
[3]   Relationship between electron density and effective densities of body tissues for stopping, scattering, and nuclear interactions of proton and ion beams [J].
Kanematsu, Nobuyuki ;
Inaniwa, Taku ;
Koba, Yusuke .
MEDICAL PHYSICS, 2012, 39 (02) :1016-1020
[4]   Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship [J].
Saito, Masatoshi .
MEDICAL PHYSICS, 2012, 39 (04) :2021-2030
[5]   Electron density measurement with dual-energy x-ray CT using synchrotron radiation [J].
Torikoshi, M ;
Tsunoo, T ;
Sasaki, M ;
Endo, M ;
Noda, Y ;
Ohno, Y ;
Kohno, T ;
Hyodo, K ;
Uesugi, K ;
Yagi, N .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (05) :673-685
[6]   Conversion of the energy-subtracted CT number to electron density based on a single linear relationship: an experimental verification using a clinical dual-source CT scanner [J].
Tsukihara, Masayoshi ;
Noto, Yoshiyuki ;
Hayakawa, Takahide ;
Saito, Masatoshi .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (09) :N135-N144
[7]   Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissues [J].
Yang, M. ;
Virshup, G. ;
Clayton, J. ;
Zhu, X. R. ;
Mohan, R. ;
Dong, L. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) :1343-1362