A 256 x 256 2-D Array Transducer with Row-Column Addressing for 3-D Rectilinear Imaging

被引:96
作者
Seo, Chi Hyung [1 ]
Yen, Jesse T. [2 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
关键词
3-DIMENSIONAL ULTRASOUND; BREAST;
D O I
10.1109/TUFFC.2009.1107
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We present simulation and experimental results from a 5-MHz, 256 x 256 2-D (65536 elements, 38.4 x 38.4 mm) 2-D array transducer with row-column addressing. The main benefits of this design are a reduced number of interconnects, a modified transmit/receive switching scheme with a simple diode circuit, and an ability to perform volumetric imaging of targets near the transducer with transmit beamforming in azimuth and receive beamforming in elevation. The final dimensions of the transducer were 38.4 mm x 38.4 rum x 300 mu m. After a row-column transducer was prototyped, the series resonance impedance was 104 Omega at 5.4 MHz. The measured -6 dB fractional bandwidth was 53% with a center frequency of 5.3 MHz. The SNR at the transmit focus was measured to be 30 dB. At 5 MHz, the average nearest neighbor crosstalk was -25 dB. In this paper, we present 3-D images of both 5 pairs of nylon wires embedded in a clear gelatin phantom and an 8 mm diameter cylindrical anechoic cyst phantom acquired from a 256 x 256 2-D array transducer made from a 1-3 composite. We display the azimuth and elevation B-scans as well as the C-scan for each image. The cross-section of the wires is visible in the azimuth B-scan, and the long axes can be seen in the elevation B-scan and C-scans. The pair of wires with 1-mm axial separation is discernible in the elevational B-scan. When a single wire from the wire target phantom was used, the measured lateral beamwidth was 0.68 mm and 0.70 mm at 30 mm depth in transmit beamforming and receive beamforming, respectively, compared with the simulated beamwidth of 0.55 mm. The cross-section of the cyst is visible in the azimuth B-scan whereas the long axes can be seen as a rectangle in the elevation B-scan and C-scans.
引用
收藏
页码:837 / 847
页数:11
相关论文
共 26 条
[1]  
BASSETT LW, 1991, AM FAM PHYSICIAN, V43, P547
[2]  
Cannata JM, 2005, ULTRASON, P109
[3]  
Christensen D., 1998, Ultrasonic Bioinstrumentation
[4]  
Ermert H, 2000, ULTRASON, P1611, DOI 10.1109/ULTSYM.2000.921632
[5]   3-D ultrasound imaging: A review [J].
Fenster, A ;
Downey, DB .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06) :41-51
[6]  
HADIMIOGLU B, 1990, ULTRASON, P1337, DOI 10.1109/ULTSYM.1990.171581
[7]   Phantom materials for elastography [J].
Hall, TJ ;
Bilgen, M ;
Insana, MF ;
Krouskop, TA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) :1355-1365
[8]   CALCULATION OF PRESSURE FIELDS FROM ARBITRARILY SHAPED, APODIZED, AND EXCITED ULTRASOUND TRANSDUCERS [J].
JENSEN, JA ;
SVENDSEN, NB .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (02) :262-267
[9]   MCTA:: Target tracking algorithm based on minimal contour in wireless sensor networks [J].
Jeong, Jaehoon ;
Hwang, Taehyun ;
He, Tian ;
Du, David .
INFOCOM 2007, VOLS 1-5, 2007, :2371-+
[10]   NEW EQUIVALENT CIRCUITS FOR ELEMENTARY PIEZOELECTRIC TRANSDUCERS [J].
KRIMHOLTZ, R ;
LEEDOM, DA ;
MATTHAEI, GL .
ELECTRONICS LETTERS, 1970, 6 (13) :398-+