Coated wire lead(II) selective potentiometric sensor based on 4-tert-butylcalix[6]arene

被引:75
作者
Bhat, VS [1 ]
Ijeri, VS [1 ]
Srivastava, AK [1 ]
机构
[1] Univ Bombay, Dept Chem, Bombay 400098, Maharashtra, India
关键词
coated wire ion-selective electrode; lead; 5,11,17,23,29,35-hexa-tert-butyl-37,38,39,40,41,42-hexahydroxycalix[6]arene; potentiometry;
D O I
10.1016/j.snb.2003.11.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A coated-wire lead ion-selective electrode (ISE) has been constructed using 5,11,17,23,29,35-hexa-tert-butyl-37,38,39,40,41,42-hexahydroxycalix[6]arene as neutral carrier in a poly(vinyl chloride) matrix. The sensor exhibited a linear Nernstian response over the range 1 x 10(-6) to 1 x 10(-1) M with a slope of 30 +/- 1 mV per decade change and a detection limit of 6 x 10(-7) M. The working pH range of the sensor is 1.5-6.0 and it shows good selectivity for Pb(II) ions over other mono-, bi- and trivalent cations. The selectivity coefficients (K-ij) were determined for Na(I), K(I), Ag(I), Mg(II), Ca(II), Ba(II), Sr(II), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Hg(II), Cr(III), Fe(III) and Al(III); the values for these ions being in the range 10(-4)-10(-2). The sensor was successfully used as an indicator electrode in potentiometric titration of lead ions with EDTA. The ISE was also used for determination of lead in electroplating bath solutions, alloy sample, battery waste samples and effluent waters. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:98 / 105
页数:8
相关论文
共 51 条
[1]   Lead(II)-selective electrode based on phenyl disulfide [J].
Abbaspour, A ;
Khajeh, B .
ANALYTICAL SCIENCES, 2002, 18 (09) :987-991
[2]   Lead-selective electrode by using benzyl disulphide as ionophore [J].
Abbaspour, A ;
Tavakol, F .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :145-149
[3]  
[Anonymous], VOGELS TXB QUANTITAT
[4]  
BAILEY PL, 1976, ANAL ION SELECTIVE
[5]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[6]  
BHAT VS, UNPUB
[7]  
BRUER G, 1963, HDB PREPARATIVE INOR, V1
[8]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[9]   Lead selective electrodes based on calixarene phosphine oxide derivatives [J].
Cadogan, F ;
Kane, P ;
McKervey, MA ;
Diamond, D .
ANALYTICAL CHEMISTRY, 1999, 71 (24) :5544-5550
[10]   COATED-WIRE ION-SELECTIVE ELECTRODES [J].
CUNNINGHAM, L ;
FREISER, H .
ANALYTICA CHIMICA ACTA, 1986, 180 :271-279